Document mgzvB41oGKjLjyG1r0bxOMB
1595
Garage (tail pipe at servic ing location)
Granite cutting, finishing Pneumatic hand tools Surfacing machine
Grinders Polishers, buffers, etc Portable
Swing frame Kitchen range
Laboratory hood (provide with door)
Metalizing
Mixers Motion picture projector
(carbon arc)
Local hood slipped over tailpipe
100 cfm through 3-in flexible duct for autos up to 200 hp
200 cfm through 4-in flexible
duct lor trucks and autos above 200 hp 400 cfm through 4'/,-m flexible
duct for Diesel engines
Local hood Local hood
500 cfm
500 cfm for tools up to 2V, in diameter
1000 cfm for 2V, to 2'/, in dia meter
2,000
Ref 15
5,500-6,000 5.500-6.000
Ref 26,27 Typical hood 3 x 8 in open
ing with 3 in flange Hood surrounds tool
Standard wheel hood Downdraft bench
Booth Booth
Canopy
(See Table 45-1) Bench type, 2-400 cfm per sq ft of exhaust grille but not less than 150 cfm per sq ft of plan working area
100 fpm at face 100-200 fpm indraft through
opening in booth face
100 fpm at hood face
Booth type Local hood Booth Enclosure Enclosure
50-100 fpm
200 fpm at hood face
125-200 fpm at booth face
100-200 fpm through feed and inspection openings
12-100 cfm (for fume and gas re moval) directly exhausted from projector housing
3,500
Ref 22,28 Ref 15,19,22,29
3,500 3,000 1,500-1,800
3,500 3,000 3,000-3,500
Recommended for larger parts (Usual cfm per gnnder
2,000-4,000)
Provide drip gutter on all intenor vertical walls to catch condensed grease Ref 30
Ref 24, 31 Air supply lo cation very critical
Ref 15 Not recommended for toxic materials
Use higher ventilation rates for toxic materials
Ref 19,22
Ref 31 1,000-1,500 cfm or 20-30 air changes per hour for heat removal