I - Heating Systems Specialties
The Clark Manufacturing Company
1830 E. 38th St., Cleveland 14, Ohio
Established 1908 *
Clark, manufacturers of steam specialties for 39 years, produces a complete line of fluid controls. They are engineered for the jobs required of them, such as heating and air conditioning and wherever air, steam or gas is used.
(Series 70)
Inverted Bucket Traps are of three general sizes: (I) small, for general drainage service (2) for greater capacity (3) for high pressure and temperatures. The combination inverted bucket and blast type (Series 70-T) has a built-in thermal-by-pass to rapidly bring systems up to operating temperature by fast elimination of air and condensate.
The Clark Patented Bucket Venting Device provided in top of bucket furnishes the means of relieving the accumu lated steam and air within the bucket.
Open (Upright) Bucket Type used for general drainage-- are available in Semi-Steel to 250 psi and Cast Steel to 400 psi. The discharge value is located at the top of the trap for easy inspection and can be replaced without removing trap from the line or breaking pipe connections.Th ey are equipped with "Clark-loy" ball type disc and seat.
(Series SO)
"CRV" Pressure Regulator is integral pilot controlled-- piston operated single seated type. It is suitable for operation at initial pressures and temperatures up to 250 psi and 450 F for cast semi-steel construction; 400 psi and 600 F for cast steel construction wherever steam, air or gas is used.
Steam Capacities (In Lbs. per Hour) of Clark "CRV" Regulators, at Various Initial Pressures
Initial Pressure
30 50 100 150 200 250
'/jin.
100 120 190 270 500 560
Vt in.
210 295 500 910 1500 2000
1 in.
345 500 1000 1180 1525 2200
1|4 in- I'/j in.
580 815 1500 2000 3000 3500
1000 1120 2500 3500 4000 5000
2 in.
1500 2000 4000 5000 7000 8000
T/2 in. 3 in.
2500 3500 6000 8000
10000 12000
4000 5000 8000 10000 15000 20000
1210
Clark Mfg. Co.
Heating Systems Specialties
Air Traps- Automatically drains water
from air lines,
air receivers,
drip pockets,
aftercoolers, etc.
Also adaptable
for draining
non-corrosive
liquids from
lines or equip
ment carrying
vapors, such as
steam and vari-
ous kinds of
No. 440
gases.
Separators-- Effectively separates, collects and removes condensate and en trained moisture from lines conveying steam, air or other gases. This saves fuel. For there is more energy per pound in dry steam than in wet.
Horizontal HCT HCT-S
Trap Std. Opt. Nos.
List Price
Wt. Lbs
Continuous Flow Capacities of Condensate in Lbs per Hour For Various Sizes at given Differential Pressure Ratings.
10 30 50 75 125 150 200 250 300 400 600
70 72
ft <A
% $ 8.00 6 Va 10.50 . 9
760 1290 1060 775 685 515 375 945 1760 1615 1250 955 730 580
73 V* 1
15JO IO>/j 1600 2600 2230 1900 1230 1025 850
ft70T
72T 73T
Yr Va
Va V, 1
11.00 13.50 18.50
7 10
II Vi
1290 1060 775 685 515
1760 1615 1250 955 730 2600 2230 1900 1230 1025
80 81
Vi
Va
. Va
1
17.00 22.50
15 26
3800 8100
1900 1560 1330 5900 3300 2940
900 2070
82 1
I/. 30.00 39
83 1*4 m 37.00 48
84 1 Vi 2
55.00 77
85 2
2Vi 73.00 117
1600
21200 35950
76000
8800 6100 5320 14000 10200 9430
21700 15400 12875
42000 32000 29300
3700
6500
11000 20000
tut Steel Series
30 Vi
31 Va
22J0 42 3000 2600 28.00 48 4200 4300
1230 1560
625 900 680* 485*
32 1
34.00 75 11080 6900
2750
1250 1335* 1080*
33 34
11 v'42
47.00 175 21000 14500 60.00 150 28000 19200
6100 8700
3750 3400* 2460* 5000 6900* 3145*
35 2
85.00 210 48000 27500
12100
7350 14600* 5100*
36 2A
120.00 330 6000 54200
27300
14500 14600* 11500*
ft800**
Va 55X0 34
801** %
68.00 57
802** I
l4 90.00 93
1230 2750 5500
850
1900 4600
680 485 1335 1080 860
3400 2460 1730
803**
\'/i 125.00 150
9500
6700
5700 4200 2820
804" ha 2
150.00 215
14300
10600
7800 6000 4200
The 800 series shown here are the screwed type. Information on the flanged and extra heavy models is available upon request.
Strainers--Both the "T" and
"Y" can be installed in steam,
air, water and other fluid lines
to remove dirt, scale, grit from
fluid flow, protecting working
parts of control valves. There
is no appreciable pressure drop
because of the straight thru flow.
The blow-off connection at the
bottom permits easy removal of
collected dirt. Screen area is
considerably greater than that
of the pipe.
.
"" Strainer .1211
"T" Strainer