Document jyJ2zNjDjOKmaQBdK8wJqGN6Z

I - Heating Systems Specialties The Clark Manufacturing Company 1830 E. 38th St., Cleveland 14, Ohio Established 1908 * Clark, manufacturers of steam specialties for 39 years, produces a complete line of fluid controls. They are engineered for the jobs required of them, such as heating and air conditioning and wherever air, steam or gas is used. (Series 70) Inverted Bucket Traps are of three general sizes: (I) small, for general drainage service (2) for greater capacity (3) for high pressure and temperatures. The combination inverted bucket and blast type (Series 70-T) has a built-in thermal-by-pass to rapidly bring systems up to operating temperature by fast elimination of air and condensate. The Clark Patented Bucket Venting Device provided in top of bucket furnishes the means of relieving the accumu lated steam and air within the bucket. Open (Upright) Bucket Type used for general drainage-- are available in Semi-Steel to 250 psi and Cast Steel to 400 psi. The discharge value is located at the top of the trap for easy inspection and can be replaced without removing trap from the line or breaking pipe connections.Th ey are equipped with "Clark-loy" ball type disc and seat. (Series SO) "CRV" Pressure Regulator is integral pilot controlled-- piston operated single seated type. It is suitable for operation at initial pressures and temperatures up to 250 psi and 450 F for cast semi-steel construction; 400 psi and 600 F for cast steel construction wherever steam, air or gas is used. Steam Capacities (In Lbs. per Hour) of Clark "CRV" Regulators, at Various Initial Pressures Initial Pressure 30 50 100 150 200 250 '/jin. 100 120 190 270 500 560 Vt in. 210 295 500 910 1500 2000 1 in. 345 500 1000 1180 1525 2200 1|4 in- I'/j in. 580 815 1500 2000 3000 3500 1000 1120 2500 3500 4000 5000 2 in. 1500 2000 4000 5000 7000 8000 T/2 in. 3 in. 2500 3500 6000 8000 10000 12000 4000 5000 8000 10000 15000 20000 1210 Clark Mfg. Co. Heating Systems Specialties Air Traps- Automatically drains water from air lines, air receivers, drip pockets, aftercoolers, etc. Also adaptable for draining non-corrosive liquids from lines or equip ment carrying vapors, such as steam and vari- ous kinds of No. 440 gases. Separators-- Effectively separates, collects and removes condensate and en trained moisture from lines conveying steam, air or other gases. This saves fuel. For there is more energy per pound in dry steam than in wet. Horizontal HCT HCT-S Trap Std. Opt. Nos. List Price Wt. Lbs Continuous Flow Capacities of Condensate in Lbs per Hour For Various Sizes at given Differential Pressure Ratings. 10 30 50 75 125 150 200 250 300 400 600 70 72 ft <A % $ 8.00 6 Va 10.50 . 9 760 1290 1060 775 685 515 375 945 1760 1615 1250 955 730 580 73 V* 1 15JO IO>/j 1600 2600 2230 1900 1230 1025 850 ft70T 72T 73T Yr Va Va V, 1 11.00 13.50 18.50 7 10 II Vi 1290 1060 775 685 515 1760 1615 1250 955 730 2600 2230 1900 1230 1025 80 81 Vi Va . Va 1 17.00 22.50 15 26 3800 8100 1900 1560 1330 5900 3300 2940 900 2070 82 1 I/. 30.00 39 83 1*4 m 37.00 48 84 1 Vi 2 55.00 77 85 2 2Vi 73.00 117 1600 21200 35950 76000 8800 6100 5320 14000 10200 9430 21700 15400 12875 42000 32000 29300 3700 6500 11000 20000 tut Steel Series 30 Vi 31 Va 22J0 42 3000 2600 28.00 48 4200 4300 1230 1560 625 900 680* 485* 32 1 34.00 75 11080 6900 2750 1250 1335* 1080* 33 34 11 v'42 47.00 175 21000 14500 60.00 150 28000 19200 6100 8700 3750 3400* 2460* 5000 6900* 3145* 35 2 85.00 210 48000 27500 12100 7350 14600* 5100* 36 2A 120.00 330 6000 54200 27300 14500 14600* 11500* ft800** Va 55X0 34 801** % 68.00 57 802** I l4 90.00 93 1230 2750 5500 850 1900 4600 680 485 1335 1080 860 3400 2460 1730 803** \'/i 125.00 150 9500 6700 5700 4200 2820 804" ha 2 150.00 215 14300 10600 7800 6000 4200 The 800 series shown here are the screwed type. Information on the flanged and extra heavy models is available upon request. Strainers--Both the "T" and "Y" can be installed in steam, air, water and other fluid lines to remove dirt, scale, grit from fluid flow, protecting working parts of control valves. There is no appreciable pressure drop because of the straight thru flow. The blow-off connection at the bottom permits easy removal of collected dirt. Screen area is considerably greater than that of the pipe. . "" Strainer .1211 "T" Strainer