Document byY5rmeyYDQd67103mr5n7jVk
DATE: SUBJECT: FROM: THRU: TO:
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION 5
77 WEST JACKSON BOULEVARD CHICAGO, ILLINOIS 60604
November 10, 2021
CLEAN AIR ACT INSPECTION REPORT Citgo Petroleum Corporation (Citgo), Lemont, Illinois
Constantinos Loukeris, Environmental Engineer AECAB (MI/WI)
Sarah Marshall, Section Chief AECAB (MI/WI)
File
BASIC INFORMATION
Facility Name: Citgo Petroleum Corporation (Citgo)
Facility Location: 135th Street & New Avenue, Lemont, Illinois, 60439
Date of Inspection: September 13-15, 2021
EPA Inspectors: 1. Constantinos Loukeris, Environmental Engineer 2. Veronica Fischer, Environmental Engineer 3. Daniel Heins, Environmental Scientist
Other Attendees 1. Jim Lant, Environmental Manager 2. Matt Klickman, Senior Air Environmental Staff 3. Mike Mee, HSE Manager 4. Drew Bollinger, BWON Coordinator
Contact Email Address: jlant@citgo.com
Purpose of Inspection: to assess compliance with requirements of NESHAP Subpart FF, NSPS QQQ and Citgo's Consent Decree
Facility Type: refinery
Page 1 of 10
Regulations Central to Inspection: National Emission Standards for Hazardous Air Pollutants for Benzene Waste Operations (BWON), at 40 C.F.R. Part 61, Subpart FF, New Source Performance Standards for VOC Emissions from Petroleum Refinery Wastewater Systems (QQQ), at 40 C.F.R. Part 60, Subpart QQQ, and Citgo's Consent Decree
Arrival Time: September 13, 2021 - 9:40 am Departure Time: September 15, 2021 - 4:55 pm
Inspection Type: Unannounced Inspection Announced Inspection
OPENING CONFERENCE
Credentials Presented CBI warning to facility provided
The following information was obtained verbally from Citgo representatives unless otherwise noted.
Process Description:
Citgo provided EPA a brief overview of how the benzene wastewater is controlled from the various parts of the refinery. In addition, Citgo provided information as to how QQQ is applicable to the individual drain systems at the refinery. A simplified process water diagram was used to explain how the plant is broken up, and also to provide details of the BWON controlled sewer section of the plant. Citgo operates a North and South Plant. In the North Plant, Citgo indicated there is no QQQ-applicable equipment due to the age of the existing individual drain systems and that no modifications, reconstruction, or construction has occurred to otherwise make them subject. In the South Plant, all the wastewater is hard piped to the South Plant effluent sump (SP PSO), which is the start of the wastewater treatment under BWON. In addition, Citgo operates a two-stage desalter system that includes a hydroclone and a flasher prior to being routed to the SP PSO effluent sump. The desalter is the primary benzene wastewater stream that is being controlled. Citgo also operates a sour water stripper to manage the sour water that is generated in the system.
The BWON controlled system consists of four floating roof tanks used for separation, an induced gas flotation (IGF) tank, two slop oil tanks, and three aeration tanks. Citgo considers the effluent stream of the aeration tanks as controlled to the levels required by BWON (i.e. <10 parts per million by weight benzene), and thus Citgo considers subsequent equipment not part of the BWON controlled system. Subsequent equipment includes two clarifiers and a treated water basin. Slop oil from the four floating roof tanks and the IGF tank used for separation are routed to either slop oil Tank 433 or slop oil Tank 434. Tank 434 was demolished and actively being rebuilt at the time of EPA's inspection.
Page 2 of 10
Citgo conducts monthly visual inspections for equipment subject to QQQ and quarterly EPA Reference Method 21 for equipment subject to BWON and QQQ drains.
TOUR INFORMATION EPA toured the facility: Yes
Data Collected and Observations:
EPA conducted leak detection and repair monitoring using a Toxic Vapor Analyzer Model 2020 (TVA 2020) flame ionization detector on Citgo's BWON sewer system components that are required to be designed to operate with no detectable emissions (NDE), which is indicated by an instrument reading of less than 500 ppm. In addition, EPA visually inspected drain hubs and other QQQ affected equipment. EPA also used the TVA 2020 for the QQQ affected equipment when accessible.
Photos and/or Videos: were taken during the inspection.
Field Measurements: were taken during this inspection.
The table below summarizes EPA's TVA 2020 monitoring results:
Component ID
119HQ115
By D401 in SRU
102WWML-26 102WWML-23 103WWML-19
WW590-8 WW 113-3
119HQ31
119WWML-8
102WWML-22
112WWML-3
Equipment Type Drain
Stormwater Drain (Grate)
Manhole Manhole Manhole
Cover Manhole
Cleanout
Manhole
Manhole
Manhole
EPA's Reading (ppm) 825
64
25,000 >10,000 21,000
1,640 1,340
1,200
80,000
20,000
900
Citgo's Reading (ppm)
660
-
545 14,000 22,000
924 779
2,160
15,859
31,000
1,221
Additional Notes
Sight Glass Blowdown to Drain Not QQQ, sludge
liquid on top of drain -
2 bolts missing on manhole cover
Cracked cover with missing metal seal. Emissions from all around the manhole
Open hole on manhole cover Caulk on sample port in middle of manhole cover cracked and dry
Page 3 of 10
111WWML-13
Manhole
119WWML-11
Manhole
North of 119G-2B
South of D3 in 119 Process Unit
Tag# 844-SPSO LL 00049 844G-444B 844SPSO LL00018
Tag# 401247
Tag#401249
Tag#401243
Stormwater Drain (Grate) Stormwater Drain (Grate) PSO Sump
Cover Drain Hatch/Cover
PSO Sump Cover
PSO Sump Cover
PSO Sump Cover
1,180
3,900
21.7 38 -
8,300
16,107
Confirmed 28
12,240 3,000 30,000 12,079 14,000 9,600
Multiple cracks in concrete around the
manhole Manhole cover has
opening with no bolt/patch Not QQQ
-
-
-
-
-
-
The table below summarizes the number of visual inspections completed by EPA by process unit:
Process Unit/Equipment Type Crude Unit Drains Manholes Cleanouts
Sulfur Recovery Unit Drains
Manholes Cleanouts Gasoline Hydrotreater
Drains Manholes Cleanouts Ultra-low Sulfur Diesel
Drains Manholes Cleanouts Naphtha Hydrotreater
Drains Manholes
Number Visually Inspected
33 8 1
128 1 8
42 11 10
56 9 8
10 4
Page 4 of 10
Cleanouts
0
Coker Unit
Drains
10
Manholes
4
Cleanouts
5
FCCU
Drains
27
Manholes
3
Cleanouts
10
Purge Treatment Unit
Drains
12
Manholes
0
Cleanouts
5
The table below summarizes the visual inspection observations identified by EPA:
Component ID
W111-3
111HQ25 111HQ57 111HQ51 111HQ32
Process Unit
Crude Unit
Crude Unit Crude Unit Crude Unit Crude Unit
111HQ28 WWML-13
Crude Unit Crude Unit
119ML-11 Sulfur Recovery Unit
119HQ8 119HQ5 119HQ15 119HQ16
119HQ18 119HQ11 119HQ20
Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit
Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit
119HQ22
Sulfur Recovery Unit
Equipment Type
Manhole
Drain Drain Drain Drain
Drain
Manhole
Manhole
Drain Drain Drain Drain
Drain Drain Drain
Drain
Observation
Debris and hose on top of manhole
Dry, no water seal Dry, no water seal Water seal appeared oily Drain appears wet on the sides, but no water
seal Level is quite high and
appeared oily Multiple cracks in concrete next to
manhole cover Opening on the cover, and also minimal debris
on top Dry, no water seal Dry, no water seal Dry, no water seal Dry, no water seal, sulfur odor present Dry, no water seal Dry, no water seal Drain appears wet on the sides, but no water
seal Dry, no water seal
Page 5 of 10
119HQ32 119HQ36 119HQ40 119HQ47 119HQ45
Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit
119HQ46 119HQ51 119HQ59 119HQ60 119HQ61 119HQ63 119HQ64 119HQ70 119HQ72 119HQ73 119HQ116 119HQ121
Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit
119HQ120 Sulfur Recovery Unit
119HQ135 119HQ130
Sulfur Recovery Unit Sulfur Recovery Unit
119HQ148 119HQ147 Near 119F36
Sulfur Recovery Unit Sulfur Recovery Unit Sulfur Recovery Unit
102HQ39 Gasoline Hydrotreater
102HQ42 Gasoline Hydrotreater
102HQ40
102HQ43 102HQ41
Gasoline Hydrotreater
Gasoline Hydrotreater Gasoline Hydrotreater
Drain Drain Drain Drain Drain
Drain Drain Drain Drain Drain Drain Drain Drain Drain Drain Drain Drain
Drain
Drain Drain
Drain Drain Drain
Drain
Drain
Drain
Drain Drain
Page 6 of 10
Dry, no water seal Dry, no water seal Dry, no water seal Dry, no water seal Dry, no water seal, debris was present in the
drain hub Dry, no water seal Dry, no water seal Water seal appeared oily Water seal appeared oily Water seal appeared oily Dry, no water seal Dry, no water seal Dry, no water seal Dry, no water seal Dry, no water seal Water seal appeared oily Dry, no water seal, debris was present in the
drain hub Dry, no water seal, debris was present in the
drain hub Dry, no water seal Dry, no water seal, debris was present in the
drain hub Dry, no water seal Dry, no water seal Dry, no water seal, insulation was present in
the drain hub Dry, no water seal, debris was present in the
drain hub Dry, no water seal, debris was present in the
drain hub Dry, no water seal, water bottle in drain Dry, no water seal Debris on the upper level of the drain, with a water seal below
102HQ22 102HQ25 102HQ5
Gasoline Hydrotreater Gasoline Hydrotreater Gasoline Hydrotreater
102WWML22 102WWML20
102HQ3
Gasoline Hydrotreater Gasoline Hydrotreater Gasoline Hydrotreater
102HQ1
Gasoline Hydrotreater
102ML23 Gasoline Hydrotreater
Drain Drain Drain
Manhole Manhole
Drain
Drain
Manhole
103ML19 590HQ33
Naphtha Hydrotreater Ultra-Low Sulfur Diesel
Manhole Drain
590HQ56 590HQ52
590HQ41
590HQ37
Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel
Ultra-Low Sulfur Diesel
Ultra-Low Sulfur Diesel
Drain Drain
Drain
Drain
590HQ35 Ultra-Low Sulfur Diesel
Drain
590HQ45 Ultra-Low Sulfur Diesel
Drain
590HQ05 590HQ06 590HQ44 590HQ08 590HQ09 590HQ32
Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel
Drain Drain Drain Drain Drain Drain
Page 7 of 10
Dry, no water seal, water bottle in drain Dry, no water seal, tube
in drain Dry, no water seal, debris was plugging the
drain hub Manhole had an open
hole in it Manhole had a cracked
concrete seam Dry, no water seal, debris was plugging the
drain hub Dry, no water seal, debris was present in the
drain hub Manhole was half covered in dirt and rocks; seal visibly broken on cover Manhole almost entirely covered under dirt Dry, no water seal, debris was present in the
drain hub Dry, no water seal Dry, no water seal, cobwebs were present Dry, no water seal, cobwebs were present Dry, no water seal, debris was present in the
drain hub Dry, no water seal, debris was present in the
drain hub Dry, no water seal, debris was plugging in
the drain hub Dry, no water seal Dry, no water seal Dry, no water seal Dry, no water seal Dry, no water seal Dry, no water seal
590HQ23 590HQ60
Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel
590HQ61 Ultra-Low Sulfur Diesel
590HQ17 Ultra-Low Sulfur Diesel
590HQ53 Ultra-Low Sulfur Diesel
590HQ22 590HQ55 590HQ39
Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel
590HQ49 590HQ58
Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel
590HQ48 590HQ11
Ultra-Low Sulfur Diesel Ultra-Low Sulfur Diesel
590HQ47 Ultra-Low Sulfur Diesel
590HQ02 Ultra-Low Sulfur Diesel
Drain Drain
Drain
Drain
Drain
Drain Drain Drain
Drain Drain
Drain Drain
Drain
Drain
590HQ62 Ultra-Low Sulfur Diesel
Drain
103HQ12
103HQ04 103HQ11 103HQ10
Naphtha Hydrotreater
Naphtha Hydrotreater Naphtha Hydrotreater Naphtha Hydrotreater
Drain
Drain Drain Drain
103HQ07 103HQ03
Naphtha Hydrotreater Naphtha Hydrotreater
Drain Drain
Page 8 of 10
Dry, no water seal Dry, no water seal, debris was present in the
drain hub Dry, no water seal, debris was present in the
drain hub Dry, no water seal, debris was present in the
drain hub Dry, no water seal, debris was present in the
drain hub Dry, no water seal Dry, no water seal Dry, no water seal, debris was present in the
drain hub Dry, no water seal Dry, no water seal, debris was present in the
drain hub Dry, no water seal Water seal present; however, spray paint
can in drain Dry, no water seal, debris was present in the
drain hub Dry, no water seal, and buried under almost 1
foot of dirt. Citgo indicated was cleaned out a few years ago.
Dry, no water seal, debris was present in the
drain hub High level present in
drain Dry, no water seal Dry, no water seal Dry, no water seal, debris was present in the
drain hub Dry, no water seal Dry, no water seal
103HQ02 113HQ22 113HQ25 113CQ29 WW113-1
Naphtha Hydrotreater Coker Unit Coker Unit Coker Unit Coker Unit
HQ01
Purge Treatment Unit
113HQ61
Coker Unit
113HQ26
Coker Unit
113 CQ31
Coker Unit
112HQ15
FCCU
Drain Drain Drain Cleanout Manhole
Drain
Drain
Drain
Drain
Drain
Dry, no water seal Dry, no water seal Dry, no water seal Located under a trailer Center hold of manhole cover with pipe running
through it to backflush/segregate
sewer. Dry, no water seal, filled
with dirt to the top of hub
Dry, no water seal, debris was present in the
drain hub Dry, no water seal, debris was present in the
drain hub Cleanout drain dry with debris present and not
sealed. Dry, no water seal
CLOSING CONFERENCE
Requested documents: EPA requested the following documents:
Quarterly BWON reports for 2019 and 2020; Total Annual Benzene Report for 2019 and 2020; End-of-Line Sampling Reports from 1st quarter 2020 through 1st quarter 2021; Semi-annual QQQ reports for 2019 and 2020; Procedure for Preparing H2S-containign pumps for Maintenance; Leak Detection and Repair Database for BWON and QQQ; PSO Design Documentation; Internal and External Inspection Reports for Tanks 433, 439, 485. 486, and 487; Tank Information on September 15, 2021: approximate level, roof seal type, and average
temperature (Tanks 433, 439, 485, 486, and 487); 22 pictures provided by Citgo indicating various repairs from the visual observations and
21 monitoring.
Method
Citgo provided responses to the requested documents via a Microsoft Onedrive link provided by EPA to Citgo.
Concerns:
1. EPA identified concerns that numerous QQQ drains were found without a water seal and in several instances, with debris present/plugging the drain hub.
Page 9 of 10
2. EPA identified concerns that the visual inspections for QQQ are not being completed properly or at all, since the presence of some of the debris indicated a significant pileup.
3. EPA observed the Alky flare smoking the entire time EPA was on top of Tank 433. 4. EPA identified the concern that BWON and QQQ manhole covers are not being sealed
properly and also found manhole covers covered in dirt in a few instances with broken seals. 5. EPA identified the concern that Citgo did not identify any modifications, reconstruction or construction to the North Plant that would have triggered QQQ. 6. EPA identified the concern of significant peeling and pitting of caulk on the SP PSO sump with detectable emissions above 500 ppm. 7. EPA identified detectable emissions above 500 ppm at drain hubs, plates, and hatches on the South Plant PSO system leading to the induced gas flotation system. 8. EPA identified the concern that the controlled sewer at certain points may not be designed to operate below NDE as required by the BWON. 9. EPA observed that gauge hatches and sample valves on top of the Tanks 433, 439, 485, 486, and 487 were not part of the BWON leak detection and repair program.
SIGNATURES
CONSTANTIN
Digitally signed by CONSTANTINOS LOUKERIS
Report Author: _____O_S__L_O_U__K_E_R_I_S_D-_0a6_t'e0:0_2' 0_21_.1_1.1_0 1_1:_42_:16______
SARAH
Digitally signed by SARAH MARSHALL
Section Chief: _____M__A_R__S_H__A_L_L___D11_a:t5_e8:_:2502_2-1_0.61_'10.0_1'0_________
Page 10 of 10
APPENDIX A: DIGITAL IMAGE LOG
1. Inspector Name: Constantinos Loukeris
3. Company/Facility Name: Citgo Petroleum Corporation (Citgo)
5. Number of Images: 33
Image Number
1 2 3
4 5 6
7
8 9 10 11 12 13
File Name
MOV_0079.mp4 MOV_0080.mp4 MOV_0082.mp4 MOV_0083.mp4
MOV_0084.mp4 MOV_0085.mp4 MOV_0087.mp4
MOV_0088.mp4
MOV_0089.mp4 MOV_0096.mp4 MOV_0097.mp4 MOV_0106.mp4 MOV_0107.mp4
2. Date(s) of Inspection: September 13-15, 2021
4. Street Address, City, State: Lemont, IL
6. Archival Record Location: OneDrive: EPAWork\Citgo\Inspection\Citgo Lemont September 2021 BWON Inspection\FLIR Images and Video
Date
9/15/2021 9/15/2021 9/15/2021 9/15/2021
9/15/2021 9/15/2021 9/15/2021
9/15/2021
9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021
Description of Image VOC emissions imaged from the manway skimmer line on top of
Tank 486 VOC emissions imaged center
vent on top of Tank 439 VOC emissions imaged from PSO
sump effluent hatch VOC emissions imaged from PSO sump effluent hatch located west
of previous one listed. VOC emissions from Drain:
844G-444B VOC emissions from PSO sump
effluent hatch VOC emissions imaged from the plate top of the PSO sump, Tag#
401247 VOC emissions imaged from the plate top of the PSO sump, Tag#
401249 VOC imaged from flange on east
end of the PSO sump VOC emissions imaged from Tag#
844-SPSO LL 00049 Digital video of hatches by the
PSO sump VOC emissions imaged from the external floating roof of Tank 433 VOC emissions imaged from the external floating roof of Tank 433
Appendices Page 1 of 2
MOV_0108.mp4
14 MOV_0109.mp4
15 MOV_0111.mp4
16
17
DC90.jpg
18
DC91.jpg
19
DC92.jpg
20
DC93.jpg
21
DC94.jpg
22
DC95.jpg
DC98.jpg
23
DC99.jpg
24
DC100.jpg
25
DC101.jpg
26
DC102.jpg
27
DC103.jpg
28
DC104.jpg
29
DC105.jpg
30
DC106.jpg
31
DC107.jpg
32
DC108.jpg
33
9/15/2021
9/15/2021 9/15/2021
9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021 9/15/2021
VOC emissions imaged from the external floating roof legs of Tank
433 VOC emissions imaged from the gauge hatch on top of Tank 433 VOC emissions imaged from the external floating roof legs of Tank
433
Digital picture tank at PSO sump
Digital picture tank at PSO sump
Digital picture tank at PSO sump
Digital picture tank at PSO sump
Digital picture tank at PSO sump
Digital picture tank at PSO sump Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system Digital picture tank of the rest of
the PSO system
Appendices Page 2 of 2