Document baqzJmg8KewBeQ2G3NgqaNpQZ
AR226-3267
449
DuPont Haskell Laboratory for Health and Environmental Sciences
AR226-3267
March 6, 2003
cciMrI m I
Qualify Assurance
TO: FROM:
MRFILi
POCKET H-25425
J. C. Maslanka
TEST SUBSTANCE STABILITY O F H-25425
Medical Research Project Number: Haskell Sample Number: Haskell Reference Standard Number: Analytical Test Code: Analytical Report Number:
Notebook References:
^25425
Attached is the analytical report for the study identified above. This analysis was performed to satisfy protocol requirements for test substance stability but may also be used for other purposes.
<**** i.
TEST SUBSTANCE STABILITY OF H-25425
Medical Research Project Number: Haskell Sample Number: Analytical Report Number:
HA-2003-032
A sample of H-25425 was submitted on February 26, 2003 a n ^ n a ly z e d g n February 27, JThyM rcentage o f active ingredient (a.i.) was measured to b e B H H H B i r i t h a M B f nominal for replicate analyses (n = 3). The sponsor reported a purity o; the sample was submitted.
ACKOWLEGEMENTS Sample preparation by Sheila A. Riley (Chemistry Associate). Sample analysis by Bogdan Szostek (Senior Research Chemist).
SIGNATURE
Report by: Date Issued:
<^L<^r Janet C. Maslanka
Analytical Staff Chemist
iff - H *<t>ts - b oO S
- Z0 0 3 Date
^ TSCl
HA -2003-032 page 2 of 2
METHODS
Analysis for the percent of a.i. in a sample o f H-25425 was by high-performance liquid chromatography (HPLC) with a Gel Permeation Column (GPC) and refractive index detector according to the following method. Sonication was used to completely dissolve the test substance and the analytical standard stock solution.
SAMPLE PREPARATION & ANALYSIS
Aliquots (0.0403, 0.0417 and 0.0409 grams) of H-25425 were dissolved in tetrahydrofuran (10 mL) to give nominal concentrations of 4030, 4170, and 4090 ppm, respectively.
CHROMATOGRAPHIC CONDITIONS
Instrument: Column: Mobile Phase Flow Rate: Injection Volume:
Column Temperature: Detection:
Hewlett-Packard Model 1100 HPLC Styragel HR 4; 7.8 mm x 300 nom (GPC column) 100% tetrahydrofuran (THF) 1.0 mL/min 50 fil 35C Refractive Index
CALIBRATION & QUANTITATION
A separate sample of H-25425 test substance was designated as the analytical reference standard (93.17% pure). A stock solution of H-25425 in tetrahydrofuran was used to make calibration solutions that bracketed the test solutions. Peak heights from replicate HPLC/GPC/RI analysis of each calibration solution were used to construct a calibration curve by least-squares regression. Measured concentrations for each test solution were determined by applying respective peak heights to the calibration curve.
RESULTS
H-25425 eluted from the HPLC column as a resolved p>i ^k witjj^ rietention time o f about
*l V9.023 0.02 minutes. The sponsor reported a purity olW t * hen the sample was submitted.
Table I. The percent of a.I. in the H-25425 sample analyzed February 27,2003
. Aliquot
____ EE2LH-25425
Percent
Nominal Measured Nominal
1 4030 2 4170 3 4090
Average %Nominal Standard Deviation Coefficient of Variation
3730 92.6 3790 90.9 3780 92.4
92.0 0 .9
1%
CompanySaMNtasA notcontain TSCA CB1