Document Znk028qKwG97DKxM2E3Jq12gd
I
Air[Syslem Equipment
Cooling Towers
The Marley Company, Inc.
Fairfax and Marley Roads, Kansas City 15, Kansas
Representatives in All Principal Cides (Consult Classified Phone Directory)
Water Cooling Towers of All Types and Capacities. Spray Nozzles
Marley NonClog Spray Nozzles
Low pressure tan gential inlet. . with high speed whirl and uniform fine spray.
ATMOSPHERIC SPRAY TOWERS Marley atmospheric towers are designed for lowest cost, high efficiency installations on roof or ground where breeze is unobstructed. They are easily installed, simple and economical to operate. No fans, motors or other moving parts are employed. Towers are sturdily constructed of heart quality redwood for long, troublefree life. These towers owe their efficiency to the use of Marley low pressure spray nozzles and distribution systems. They are made in a wide range of closely graduated sizes and are shipped complete with necessary hardware, reaay to erect.
Two-Piece Nozzle
for all cooling and spraying. Readily cleaned.
MARLEY AQUATOWERS Marley Aquatowers are built and shipped as complete units and are remarkable for simplicity of in stallation and operation. Their small space requirement makes them ideal for many applications either indoors or out. They are steel cased and are filled with nail less redwood filling that retains correct alignment. Aquatowers are produced in two styles and seven sizes for specified refrigera tion loads.
One-Piece Nozzle for cooling lowers, spray ponds;. large capacity-
Atomizing Nozzlefor humidifying vapor izing; a "mist-like" spray.
SMALL SERIES VERTICAL STEEL These attractive induced draft steel cased towers are designed for medium capacity refrigeration and air-conditioning service. Small Series Vertical towers are equipped, with Marley Triple Effect eliminators, Marley low pressure spray nozzles and distribution system. They are prefab ricated and piece-marked for simplified field assembly. V-belt fan drive is stand ard equipment for all models. Marley Geareducers are available for larger capacity towers.
MARLEY DOUBLE-FLOW TOWERS For large capacity installations, Marleyjpatented Double-Flow towers are designed to provide maximum efficiency and flexibliity.
i i on
Air System Equipment cooling Towers
equipment division J. F. Pritchard & Company
908 Grand Ave., Kansas City 6, Missouri
New York, Chicago, Los Angeles, Houston, Pittsburgh, St. Louis, Tulsa Representatives in Other Principal Cities
THREE LEADING LINES--Cooling Towers, Heat Exchangers, Gas Equipment for FIVE MAJOR FIELDS--Chemical. Natural Gas, Petroleum, Power and Refrigeration
COOLING TOWERS--Ca pacities ranging from small steel models for air condi tioning up to heavy-duty induced draft industrial towers. Patented fans and drives developed for specific duties show distinct ad vantages. Specifications, prices, rating and applica tion recommendations fur nished promptly, without obligation. Shipment from stock.
Medium Sized Industrial Induced Draft Type Tower
Mechanical Draft Towers--Conventional or "coil type"
induced draft counter-flow designs achieve greatest
cooling efficiency. All sizes available with redwood or
steel frames, fireproof sheathing, double-wall casing. Ex
clusive features include wrought Monel FEATHER
WEIGHT FANS*, SEALDFLOW* ventilated fan drive
units; low pumping head; trouble-free water distribution.
Natural Draft Towers--Deck towers with
Horizontal Airflow Steel Towers for Air Conditioning installation*
.DRIFT-RETRIEVER* louver design, minimizing drift loss without restrictive secondary louvers. High operating ef ficiency, low operating costs, soundly
engineered. Spray towers, any capacity for roof or ground installation. Slip-fit louvers. Simple to assemble. Redwood construction. Shipped complete.
Packaged Towers-- Available in steel (painted or galva nized), aluminum or
Monel. Completely assembled or knocked down for field assem..bly. Ideally suited for refrigeration and air conditioning systems,
air compressors, etc.
HEAT EXCHANGERS--All types of .heat transfer apparatus, high or -low pressure, shell-and-tube, atmospheric, etc., in standard or special design. QUINTAIR* air-cooled heat exchangers adaptable for jacket water cooling, steam condensing and AIRDFINS* for cooling vapors, gases, oils, acids, other fluids. Open, simple, sturdy construc tion allows for easy maintenance and mechanical reliability.
GAS EQUIPMENT --Includes
Standard "Package Type"Replacement equip ment for any make of
existing towers in cludes SEALDFLOW*
fan drives, conven
tional right angle fan
drives, all-Monel direct drive self-con
tained units, and FEATHERWEIGHT*
fans. SEALDFLOW Fan
Drive
H YDRYERS*, package type units for air and gas drying, using any one of several
solid desiccant ma terials.
Total or con trolled dehydra tion in any capaci ty. Standardized for specific appli cations. 3-ZONE* cleaners and sep arators, horizontal or vertical types for air, gas and steam; and special
'Registered trade names for specialized equipment produced by J. F. Pritchard & Co.
__________________ mist-extracting `Laboratory Size" Air Dryer applications.
1131