Document Z4G1b425Y62G5jqo4yqQZLKjV
r
ARA.H& _ \H-kq
H
/ il
D O N 'T S A Y IT-W R ITE IT
To. FRANK A.- BOWER
From RAY MORROW
'Vy.
Subject.
MEETING WITH 3M MAY 30
.Location .location
PETCHEM-FREON PRDTS LAB -CHESTNUT RUN
HASKELL LAB
No. 366- 43S6 Dot* 5/15/78
T. L. Cairns, CR&D-Wilm. CFR/BCM J. R. Gibson
Attached is a copy of a paper by Guy and Taves concerning organic fluorocompounds in human plasma. The discussion section deals specifically with possible environmental sources of perfluorinated fatty acids. The paper was presented at a symposium sponsored by Divisions of Fluorine and Biolgical Chemistry at the 170th Metting of the American Chemical Society, Chicago, Illinois, August 26, 1975 and published in the ACS Symposium Series 28, by the American Chemical Society, 1976.
RWM/taa Attachements
C-1 *tv. 10-62
SECURITY IS AN IN D IVIDU A L RESPONSIBILITY
R E C E IV E D MAy 1 b 1978
BRUCE w- karrh, m j>.
RL001539
EID107111
000099
Presented at a symposium sponsored by the Divisions of Fluorine and Biological Chemistry at the 170th Meetina
^Inerican Chemical Society, Chicago, 111., Aug.
Published by the American Chemical Society, 1376. "7
Organic Fluorocompounds in H um an Plasma: Prevalence and Characterization
w. s. CUY
Department of Basic Dental Sciences, University of Florida, Box J424, Cainsville, Fla. 32610 D. R. TAVES Department of Pharmacology and Toxicology, University of Rochester, Rochester, N.Y. 14642 W. S. BREY, JR. Department of Chemistry, University of Florida, Cainsville, Fla. 32611
Taves discovered Chat samples of his own blood serum con tained two distinct forms of fluoride (1-4). Only ons of these was exchangeable with radioactive fluoride. The other, non exchangeable form was detectable ae fluoride only when sample preparation included ashing. This paper is concerned with three aspects of this newly discovered, non-exchangeable form: 1 ) its prevalence in human plasma, 2) how its presence in human plasms affects the validity of certain earlier conclusions about the metabolic handling of the exchangeable form of fluoride, end 3) its chemical nature.
Preliminary work in this laboratory suggested that the non exchangeable form was widespread In human plasma but did not exist in the plasma of ocher animals. Ashing increased the amount of fluoride an average of 1.6 0.25 SD pH (range 0.4-3.0) in samples of plasma from 35 blood donors in Rochester, N.Y. ( 5 ) . No such fluoride was detectable (above 0.3 pH) in blood serum from eleven different species of animal including horse, cow, guinea pig, chicken, rabbit, sheep, pig, turkey, mule end two types of monkey (6).
Standard methods for analysis of exchangeable fluoride in sensa have in the pest Included ashing as e step Ih sample preparation ( 7 ) . Taves showed that the amount of fluoride in serum that would mix with radioactive fluoride vas only about one-tenth the amount generally thought to be present baaed on analyses using these older methods (4). When plasma samples from individuals living in cities having between 0.15 ead 2.5 ppm fluoride in their water supply were analysed by these older methods, no differences were found between the averages for the different cities. This led to the conclusion that "homeostasis of body fluid fluoride content results with intake of fluoride up to and including that obtained through the use of veter with e fluoride content of 2.5 ppm" (8). If the non-exchangeable form of fluoride predominated In these samples, differences In the exchangeable fluoride concentration would probably not have been " apparent, end it would be unnecessary to postulate such rigorous
117
EID107112
000100
f
RL001540
113
BIOCHEMISTRY INVOLVING CARBON-FLUORINE BONDS
homeostatic control mechanisms for fluoride. In this study plasma samples were collected from a total of
106 individuals living in five different cities with between 0 . 1 and 5.6 ppm fluoride in their public water supply. These were analyzed for both forms of fluoride. In this way the relation ship between exchangeable fluoride concentration in the plasma and the consumption of fluoride through drinking water was re evaluated, and the prevalence of the non-exchangeable form was further studied.
With respect to the chemical nature of the non-exchangeable form of fluoride several lines of evidence suggested that it was some sort of organic fluorocompound of Intermediate polarity, tightly bound to plasma albumin In the blood. It migrated with albumin during electrophoresis of serum at pH nine (3) and was not ultrafilterable from serum (2). Attempts at direct extrac tion from plasma with solvents of low polarity like heptane, petroleum ether and ethyl ether were generally unsuccessful. Treatment of albumin solution (prepared by electrophoresis of plasma) with charcoal at pH three did remove the bound fluorine fraction. And finally, when plasma proteins were precipitated with methanol at low pH the fluorine fraction originally bound to albumin appeared in the methanol-water supernatant In a form which still required ashing to release fluorine as inorganic fluoride (5). Based on these considerations the non-exchangeable form of fluoride in human plasma Is referred to as "organic fluorine" throughout the rest of this paper.
In order to further characterize the organic fluorine fraction. It was purified from 20 liters of pooled human plasma and characterized by fluorine nmr.
Materials and Methods
Analytical Methods. Values for organic fluorine were calcu lated by taking the difference between the amount of inorganic fluoride In ashed and unashed portions of the same material.
The following procedure was used to prepare ashed samples: 1) samples (sample size for plasma was 3 ml) were placed in platinum crucibles and mixed with 0 .6 mmoles of low fluoride MgClj and 0.1 mmoles of NaOH, 2) these vere dried on a hotplate and then ashed (platinum lids in place) for 2-4 hr at 600* C in a muffle furnace which had been modified so that the chamber received a flow of air from outside the building (room air Increased the blank and made It more variable), and 3) ashed samples were dissolved In 2 ml of 2.5 N HjSO^ and transferred to polystyrene diffusion dishes using 2 rinses with 1.5 ml of water.
The following procedure was used for separation of fluoride from both ashed and unashed samples: 1 ) samples (sample size for unashed plasma was 2 ml) vere placed In diffusion dishes (Organ Culture Dishes, Falcon Plastics, Oxnard, Calif., absorbent
7. c u d r r a l .
'litoroa
removed, rinsed with, and agitated with a gt for 30 min to remove tion (0.5 ml, 0.01 H was placed In a small diffusion dish, 1 drop sample to decrease sur more uniform between lid with a small hole Into place with petrol ane (Dow Coming, Flul was Injected through hole was sealed lmmad paraffin film; and 3) for at least 6 hr, dif and trapping solutions checked at this point and dried In a vacuum presence of a NaOH des
Fluoride was date electrode. The system oriented In an Inverted Cambridge, Maas.), a plastic vapor shield electrodes forming an saturated tissue paper evaporlzatlon of the (model 401, Orion).
Samples vere pre of 1 M HAc was drawn Micro Sampling Kit, Sp Calif.) and deposited the crapping solution micropipette was used solution was then trana electrode and the refer Surfaces of the two ele
Samples vere read tion and sets of sample standards. These stanc during a run. First, surfaces to equilibrate samples and to make the analyst to take reason! one minute. Secondly, readings used In prepa
Values for ldenti averaged and the averaj These vere then divide
OOOlOl
CUT E T A L. Flttorocompounds in Human Plasma
119
removed, rinsed with water), acidified with 2 ml of 2.5 H H^SO^, and agitated with a gentle swirling action on a laboratory shaker for 30 min to remove C02; 2) for each sample the trapping solu tion (0.5 ml, 0.01 N NaOH + phenolthalein-p-nitrophenol indicator) vas placed in a small polystyrene cup in the center-veil of the diffusion dish, 1 drop of 102 Triton-X 100 was added to the
-I sample to decrease surface tension and make the diffusion rate
more uniform between samples containing plasma and those not, the lid with a small hole made near its lateral margin vas sealed into place with petroleum Jelly, 0.02 ml of 4Z hexamethyldleiloxane (Dow Corning, Fluid 200, 0.65 cs, Midland, Mich.) in ethanol vas injected through the hole in the lid into the sample, and the hole vas sealed immediately with petroleum Jelly and a strip of paraffin film; and 3) samples were diffused with gentle swirling for at least 6 hr, diffusion vas terminated by breaking the seal, and trapping solutions were removed (the Indicator color vas checked at this point to Insure that they were still alkaline) and dried in a vacuum oven (60* C, 26 ln-Hg vacuum, in the presence of a NaOH desiccant).
Fluoride vas determined by potentiometry with the fluoride electrode. The system used consisted of a fluoride electrode oriented in an inverted position (model 9409A, Orion Research Inc. Cambridge, Mass.), a calomel reference electrode (fiber type), a plastic vapor shield which just fitted over the bodies of both electrodes forming an enclosed sample chamber in which watersaturated tissue paper vas placed above the sample to prevent vaporization of the sample, and a high impedence voltmeter (model 401, Orion).
Samples were prepared and read in the following vay: 10 pi of 1 M HAc was drawn into a polyethylene mlcroplpette (Beckman Micro Sampling Kit, Spinco Div., Beckman Inst. Co., Palo Alto, Calif.) and deposited into the cup containing the residue from the trapping solution after drying; the flexible tip of the micropipette was used to wash down the vails of the cup; and the solution vas then transferred to the surface of the fluoride electrode and the reference electrode brought into position. Surfaces of the two electrodes were blotted dry between samples.
Samples were read in order of increasing expected concentra tion and sets of samples were read between bracketing calibration standards. These standards were used in two different ways during a run. First, they were flooded onto the electrode surfaces to equilibrate them to concentrations expected for samples and to make them uniform. This procedure permitted the analyst to take reasonably stable readings for samples within one minute. Secondly, they were used In 10 til volumes for readings used in preparing the standard curve.
Values for identical samples (usually triplicates) were averaged and the average blank vas subtracted from sample means. These were then divided by the average fractional recovery of
RL001542
EID107114
000102
120 BIOCHEM ISTRY 1NVOLV1XC CARBON-FLUORINE BONDS
fluoride (usually 90 to 95Z) in standards treated the same way as
the sample set.
Plasticware (Falcon Plastics) was used for all analytical
procedures to avoid contamination by fluoride from glass, liquid
volume measurements were made with 1 , 5 and 10 ml polystyrene pipettes and a polycarbonate volumetric flask (100 ml).
Reagents were purified to insure uniformly low blanks.
Water was redistilled and deionized. Acetic acid and ammonia
were redistilled. Fluoride contamination in MgCl2 (analytical
grade) was reduced by preparing a 1 M solution containing UC1 to
pH 1 and scrubbing with hexamethyldisiloxane vapor in a column
through which the solution was continuously recycled. Following
scrubbing the solution was boiled to one third volume to remove
any residual volatile silicones and then made just basic with NH<,0H. Fluoride contamination in H2S0i, was reduced by repeated
extractions of a 6.7 N solution with hexamethyldisiloxane and
then boiling to one third volume to remove the residual silicone.
Buffered calibration standards were made from the same NaOH
'
and HAc stock solution; as for samples.
v
The blanks for ashed samples ranged between 0.2 and 1.5
nmoles fluoride and were typically about 0.5 nmoles. The blanks
were smaller for unashed samples; these ranged between 0.05 and
0 .2 nmoles fluoride and were typically about 0 . 1 nmoles.
Factors affecting jgcovery of fluoride during diffusion
were Investigated with F" tracer. Recovery during diffusion
was 97Z after 60 min from 5 ml containing 2 ml of plasma.
Increasing the acidity of the sample up to 5 N, the volume of the
sample up to 7.5 ml, the amount of cold F~ up to 1 pinole, the
amount of fluoride complexors up to 1 pmole of Th(N0j)i, had no
material effect on the rate of fluoride diffusion. The absence
of both plasma and detergent in the sample compartment markedly
slowed the rate of diffusion. Not shaking the sample also slowed
the rate of diffusion. Increasing the alkalinity of the trapping
solution to 0.1 N increased the rate of diffusion but the lower
concentration, 0.01 N, was required here to permit a lower ionic
strength in the sample reading solution.
Overall recovery of added cold fluoride was measured. In
samples containing neither plasma nor detergent the
recovery after 6 hr diffusion averaged 93Z and 95Z for ashed and
unashed samples, respectively. In samples containing plasma the
recovery was 95Z after 3 hr diffusion.
;
The degree to which fluorine from organic fluorocompounds
could be fixed as inorganic fluoride by ashing varied from less
than 1Z for volatile compounds like p-aminobenzotrlfluoride,
m-hydroxybenzotrifluorlde, benzyl fluoride and benzotrifluorlde
to over 80Z for less volatile compounds like 5-fluorouracil,
"
fluoroacetate and p-fluorophenylalanlne.
^
Methods used here for separation of fluoride (diffusion at
2
m u temp.) (9) and its quantitation (fluoride electrode) (10) are
considered to be quite specific for fluoride. One potentially
BEST COPY M A
7. m e t a l . F lu oro com pou n ds in H um an P lasm a
121
important interference, however, was codiffusable organic acids which night partially neutralize the trapping solution and thus lower the pH of the buffered reading solution. Indeed, it was found that samples containing relatively large concentrations of acetic acid (e.g., fractions 2, 3 and 4 from step 4 in the purification system) completely neutralized the trap within a few hours. The significance of this problem in the analysis of fluoride in blood plasma was investigated in two ways. First, four samples of human plasma were allowed to diffuse for three weeks, and no change in the color of the phenolphthalein indica tor in the trapping solution was observed. Secondly, samples containing the same plasma were diffused for different periods up to 158 hr and the apparent fluoride was determined. Mo changes were observed between samples which correlated with diffusion time.
The sensitivity of the analytical method was limited by the blank rather than the sensitivity of the instruments used. Reproducibility varied with the amount of fluoride being measured. The coefficient of variation averaged 55Z in the low range (samples containing 0.25 to 0.75 nmoles F ) and 6 .6Z in the high range (10-12 nmoles F~).
Blood Plasma. Human plasma was obtained from blood banks in five cities. According to public records these cities had not changed the fluoride concentration of their public water supply for at least six years prior to obtaining the samples. Samples were received in individual polyethylene bags which were part of the Fenwall ACD blood collection system. In blood collection using this system 450 ml of blood is drawn into a bag containing 67.5 ml of anticoagulant acid citrate dextrose (ACD) solution. When the cells are removed the ACD solution remains in the plasma. Because of this dilution of plasma a correction factor of 1.3 was applied to values obtained here for the concentration of fluoride. The potential error in this factor was 0 . 1 because of variation between standard limits for hematocrit and minimum volume of the blood donation. Bovine blood was obtained at slaughter and mixed immediately with ACD solution in 1 liter polyethylene bottles.
Electrophoresis. A continuous flow electrophoretic separator (model FF-3, Brinkman Inst., Inc., Westbury, N.T.) was employed. Sample flow rate was 2.3 ml/hr, buffer flow rate was 72 ml/hr, voltage was 0.67 lev, and current was 140 mamp. Separa tion took 19 hr. Plate separation was 1 mm and operating tempera ture was between 2 and 4* C. The buffer was 0.12Z (NHOjCOs, made by bubbling CO2 from dry ice into redistilled NHt,0H until the pH reached 9.0.
RL001544
EID107116
000104
122
BIOCItEMISTOY INVOLVING CAIIDON-FLUOIUNE BONDS
Purification System. Steps In the purification system are summarized in table I. In the first step one liter of plasma (pooled from 5-6 individuals) was dialysed in seamless cellulose tubing (1 in. diameter) against 20 liters of water at 4* C. The dialysate was changed twice at 24 hr intervals. In the second step dialysed plasma was freeze dried.
In the third step the dried powder from electrophoresis was extracted with methanol in a soxhelet extraction apparatus (model 6810 G, Ace Glass, Inc., Vineland, N.J.). Cellulose extraction thimbles (model 6812 G, Ace Glass) were soaked overnight in methanol. Operating conditions were 25* to 30* C under a vacuum of 24 in-Hg. Coolant for the condenser was 80Z ethanol; inlet temperature was -10* to -20* C and outlet tempera ture was -10* to 0*. Two liters of methanol were refluxed through the apparatus for a period of 4 hr and approximately 400 ml were lost to evaporation during that period. Glass beads were placed in the flask to prevent bumping.
In the fourth step the residue from the methanol extract was fractionated according to the method described by Slakotos and Rouser (1 1 ) for separating lipid and non-lipid components. The method is based on liquid-liquid partition in a column containing a dextran gel (Sephadex G-25, coarse, beaded, Pharmacia Fine Chemicals, Inc., N.Y.). Four eluents are used: 1) 500 ml chloroform/methanol, 19/1, saturated with water, 2) 1000 ml of a mixture of 5 parts of chloroform/methanol, 19/1, and 1 part of glacial acetic acid, saturated with water, 3) 500 ml of a mixture of 5 parts chloroform/methanol, 19/1, and 1 part glacial acetic acid, saturated with water, and 4) 1000 ml of methanol/water, 1/1. Their method was modified for use here by increasing the column length to that attained by using a full 100 grams of dextran beads. Sample size corresponded to that from 2.5 liters of the original plasma.
In the fifth step the residues from eluents 2 and 3 from two runs of step four were combined, applied tor a silicic acid column, and eluted by reverse flow with an exponential gradient of increasing amounts of methanol in chloroform. The column (model SR 25/45, 2.5 cm i.d. x 45 cm, Pharmacia) was filled to a height of 30 cm with silicic a d d (Unisll, 100-200 mesh, Clarkson Chem. Co., Inc., Williamsport, Pa., heat activated at 110* C for 2 days) and was washed with a complete set of elution solvents before use. The gradient maker (model 5858, set 4, Ace Glass Co.) was filled with 1 liter of methanol in the upper chamber and 2 liters of chloroform in the lower. The flow rate was adjusted by the height of the solvent reservoirs to an average of 3 ml/min for the first liter of eluent. The sample had to be transferred to the column by repeated washings with chloroform because of its low solubility in this solvent. This usually required about 30 ml of chloroform total. Dead volume for the system as 90 ml. Fractions of 15 ml volume were collected in carefully cleaned glass tubes.
BEST COPY AVAILABL
h . fT-
CUT ET AL. Fluorocompounds in Human Plasma
123
Table I
PROCEDURE FOR PURIFICATION OF FLUOROCOMPOUNDS FROM BLOOD PLASMA
Fraction Treated__
blood plasma
plasma proteins & protein-bound slabstanees in water solution
plasma proteins & protein-bound substances
Treatment
step 1 : exhaustive dialysis against distilled water
step 2: lyophili sation
Fraction Removed
smaller, watersoluble components
water
step 3: methanol extrac tion-- soxhelet, 25*C, 24 ln-Hg vacuum
plasma proteins
plasma lipids
step 4: column chromatography-- liquid-liquid partition on Sephadex
lipids o low polarity and residual polar contaminants
polar lipids
step 5: column chromatographyadsorption on silicic a d d
unknown: several yellow fractions
*J.-
RL001546
Figure I . Relationship betw een the concentration of
fluoride in human plasm a an d the concentration o f fluo ride in the drinkingw ater
EID107118
Q0106
121
BIOCHEMISTRY IXVOLMNC CARBON-FLUORINE BONDS
7. CUY ET AI_ Fluomgqm
K IM M fUQtXNCr
ANOtCWS, TfIAS SA
miMO*o.2u-1zAS
cotrus o u ist i.U i a s
____
(
--I---I--I--I--- 1--I--r 11 M------1--- 1--I--i--- 1--I--: 1 I'll at aii 02 03 Q4 06 0J 10 15 20 30 40 60 60 10
FtASMA
rM
Figure 2. Relationship between the concentration of organic fluorine in human plasma and the concentration of fluoride in
the drinking water
8
I
31 41 TUBE NO. fig u re 3. Separation o f fluoride and organic fluorine in human plasm a by electrophoresis. A sam ple (about 45 m l) of human plasm a teas electrophoresed in pH 9 buffer and fractions between the sam pling port (near tube 7 2 ) and the positive pole (near tube l ) were analyzed for this fluoride content o f both ashed and umnashed aliqu ots. Relative concentrations of proteins w ere estim ated by absorbance a t 280 nm.
BEST COPY AVAIL/*! LE
Tubing and lene (supplied
All solvents vere* ACS certified (Fisher Sc analytical reagent grade St. Louis). Solvents ye evaporator.
KMR. The mar spect spectrometer with Nicola The sample was dissolved CH3OH and CDCI3 and spec referencing to CFCI3 was are expressed with posit frequency). External la pulse length of IS micro cycles of 2.5 sec, and a processing.
R esults
Values for inorgani (R-F) in 106 plasma sam{ are shown in table II. concentration in plasma concentration in the wal fluorine concentration i fluoride in plasma and.c by inspection of values of the values within cil both cases the distrlbul with only 3 or 4 indivic of ttie two individuals 1 (figure 2, Andrews groui levels were both in exci ment for organic fluorli organic fluorine was 1 .'!
Plasma was electro] findings of Taves Q ) ui Results shown in figure that a predominant fora with albumin at pH 9, a were clearly separated.
The recovery mass in the purification sys table III. These data amount of organic fluor peak from silicic a d d for in other fractions presumably because of a
1VS*v
7. cur e t a l . Fluorocompounds in Human Plasma
125
Tubing and fittings to the columns were polytetrafluoroethylene (supplied largely by Chromatronix, Inc., Berkeley, Calif.).
All solvents were redistilled. Methanol and chloroform were ACS certified (Fisher Scientific Co.) and acetic acid was analytical reagent grade, U.5.F. (Mallinckrodt Chemical Works, St. louis). Solvents were removed from samples in a flash evaporator.
NMR. The rear spectrum was obtained on a Varlan XL-100 spectrometer with Nicolet Technology Fourier Transform accessory. The sample was dissolved in an approximately 1/1 mixture of C H 3OH and CDCI3 and spectra were run in a 5 mm tube. External referencing to CFCI3 was used for the chemical shifts, and these are expressed with positive numbers to lower field (i.e., higher frequency). External lock was used. Typical conditions were a pulse length of 15 microseconds, a delay time between pulse cycles of 2.5 sec, and a time constant of -1 sec for exponential processing.
Results
Values for inorganic fluoride (F~) and organic fluorine (R-F) in 106 plasma samples from humans living in five cities are shown in table II. These data show that the average fluoride concentration in plasma is directly related to the fluoride concentration in the water supply, and that the average organic fluorine concentration in plasma is not. No relationship between fluoride in plasma and. organic fluorine in plasma was apparent by Inspection of values for individual samples. The distributions of the values within cities are shown in figures 1 and 2. In both cases the distributions appear to be log normally distributed with only 3 or A individuals surprisingly deviant. In the cases of the two individuals with little or no apparent organic fluorine (figure 2, Andrews group, left margin), the inorganic fluoride levels were both in excess of 7 uM, making the difference measure ment for organic fluorine difficult. The overall mean value for organic fluorine was 1.35 0.85 SD iM.
Plasma was electrophoresed in an attempt to reproduce the findings of Taves (3) using plasma from another individual. Results shown in figure 3 closely match those found earlier in that a predominant form of organic fluorine appeared to migrate with albumin at pH 9, and in that organic and inorganic forms were clearly separated.
The recovery, mass balance and purification factors for steps in the purification system listed in table I are recorded in table III. These data show that about one-third of the original amount of organic fluorine in plasma is recovered in the major peak from silicic acid chromatography. Another third is accounted for in other fractions and the rest is not accounted for, presumably because of adsorption to surfaces of containers In
if-*
EID107120
RL001548
000108
yrsw.
126
BIOCHEMISTRY INVOLVING CARBON-FLUORINE BONDS
Table II
CONCENTRATION OF FLUORIDE (F~) AND ORGANIC FLUORINE (R-F) IN BLOOD PLASMA SAMPLES FROM FIVE CITIES HAVING DIFFERENT FLUORIDE CONCENTRATIONS IN THEIR WATER SUPPLY
TF-] in Plasma*. uM
TR-F1 in Plasma*''*. uM
City ([F~] in Meant
Water, pom)
SD(n)
Albany, N.Y. (<-l)
0.38* 0.21 (30)
Rochester, N . Y . (1.0)
0.89 0.75 (30)
Corpus Christi, 1 .0*
Tex. (0.9)
0.35
(1 2 )
Hillsboro, T e x . (2.1)
1.9 0.9
(4)
Andrews, Tex. (5.6)
4.3i 1.8
(30)
Range 0.14-
1.1
0.354.2
0.601.7
0.602.6
1.48.7
Diff.C Meant P<.05 SD(n)
slg, U S slg. 8lg.
1 .2 0.6 (30)
1 .6+ 1.2 (30)
1.3t 0.9 (1 2 )
2.31 0.6
(4)
l.li 0.5 (30)
Range 0.3-
2.6
0.56.8
0.43.9
1.52.8
0.1 2.3
Diff.C,d P<.05
Q.8 . n.s. & 8 sig.
*Each value used In the computation was the average of at least three replicate analyses and was corrected for dilution by
. ACD solution bymultiplying it by 1.3. "taken to be the difference between the amount of Inorganic
fluoride measured In ashed and unashed aliquots of the same c sample Tby t-test assuming equal variance in each group "The difference between Rochester andAndrews Is statistically
significant.
i?
* -
.Jt > . * d
-
; * 4 7 ; J
7. CITY E T A I_
Fl
MASS BAI FACTOR FOB
______ Fraction human plasma (ACD, 2.S liter batch)
Methanol Extractlc extract
residue
Sephadex Column Fraction I
Fractions II + I
Fraction IV
Silicic Acid Colui major peak other peaks combined
*mean SD(n) "percent of the a
mean i SD ceatlmate baaed o . of the major
estimate baaed o
000109
000110
RL001550
5eEae
aranrtMiegfflra
BIOCIIEMISTTIY INVOLVING CAHBON-FLUOHINF. BONOS
7. CUY C T A l_
F lu oro a
150 300 150-
HUMAN PLASMA BATCH I
BATCH 2
FLUORIDE AFTER ASHING n moles
150 300i 150 -
BATCH 3 BATCH 4
25 BOVINE PLASMA
I -- - . -
0 10 20 30 4 0 SO 60 70 80 90 100
. TUBE NO.
Figure 4 D istribution o f organic fluorina from human and bovine plasm a in
fractions from silicic a d d chrom atography
which samples were pli The blank for th
using bovine rather tl detectable in the ori| the sample was dlalys
tate making the eeasui Some organic fluorine 0.13 0.11 SD UM (n-< small difference, was not found in the i from human plasma as |
Human plasma had" solution. Analysis ol analysis of blood plai showed that not more 1 plasma could have com
The distribution silicic acid chromatoj batches corresponding There is clearly one t same elution position with column use and tl adaorbant). There we: they varied in sire ai
The sample used : combining the fractioi the four batches. Mu< had been used for oth combined sample was r single sharp peak obt. central portion of th fluorine.
Four sample runs 15,000 to 17,000 scan in all but one run, w were consistent with chemical shifts shown mixture showed no ins contributed to the sp perfluoro-octanoic ac son of the shifts in a d d show that there 2 ppm except for the E) where the shift la be considered a sign! was used for each. 1 consistent with the f possibly with the pr* functional group. Or the spectrum is the {
BEST COPY AV/mABLE
000111
i3-*T
CUY ET A L Fluorocompounds in Human Plasma
129
which samples were placed. The blank for the purification process was obtained by
using bovine rather than human plasma. No organic fluorine was detectable in the original bovine sample but as a further check the sample was dialysed to remove inorganic fluoride to facili tate making the measurement for organic fluorine by difference. Some organic fluorine was apparent in dialysed bovine plasma: 0.13 0.11 SD uM (n-6), a statistically significant though small difference. This trace amount of organic fluorine clearly was not found in the same silicic fractions as the dominant peak from human plasma as shown in figure 4.
Human plasma had been stored in polyethylene bags with ACD solution. Analysis of ACD solution from unused blood bags and analysis of blood plasma before and after placing it in the bags showed that not more than 5Z of the organic fluorine in human plasma could have come from this source.
The distribution of organic fluorine in fractions from silicic acid chromatography are shown in figure 4 for four batches corresponding to 5 liters of the original plasma each. There is clearly one dominant peak lying in approximately the same elution position for each batch (the exact position varied with column use and the degree of hydration of the silicic acid adsorbant). There were always some smaller secondary peaks, but they varied in size and position relative to the major peak.
The sample used for characterization by nmr was obtained by combining the fractions containing the major peaks in each of the four batches. Much of the material from batches one and two had been used for other purposes prior to this combination. The combined sample was rechromatographed on silicic acid and a single sharp peak obtained. The final sample was taken from the central portion of that peak and contained 3.3 pmoles of organic fluorine.
Four sample runs were made on the nmr spectrometer with 15,000 to 17,000 scans each and with a sweep width of 15,151 Hz in all but one run, where it was 7,576. The results of all runs were consistent with the spectrum shown in figure 5 and the chemical shifts shown in table IV. A blank run on the solvent mixture showed no Instrumental artifacts which might have contributed to the spectrum. Chemical shifts determined for perfluoro-octanolc acid are also Included in table IV. Compari son of the shifts in the unknown with that of perfluoro-octanolc a d d show that there Is a constant difference in shifts of about 2 ppm except for the -CFj- peak next to the functional group (peak E) where the shift is about 6 ppm. Only the latter la enough to be considered a significant deviation since external referencing was used for each. The difference in shift for peak E Is consistent with the presence of amide or ester derivatives, or possibly with the presence of a sulfonic a d d derivative as the functional group. One explanation for the additional peaks In
the spectrum is the presence of branched Isomers, peaks A and B
RL001552
EID107124
000112
130
BIOCHEMISTRY INVOLVINC CAIIBOX-FLUORINE BONDS
7. CUY E T AL.
F lu o ro c t
Table IV
representing - C F 3 groo
RESULTS OF KMR SPECTROSCOPIC ANALYSIS
Peak Designation
A
B
C D
Chemical Shift , ppm
Sample -70.7 -71.9 -80.0 -81.0
Perfluorooctanolc Acid
-82.6
Suggested Assignments
-CF3 groups at branch points
terminal -CF3 in branched isomers terminal -CF3 In
straight chain
groups two carbons rea representing -CFz - nex
The sample was res characterization by nm fluorine was apparent, perfluoro-octanoic acl ashing was found to be
Discussion
These findings Bug of human tissues with derived from commercia this subject is in acc series of compounds ha here for the predomina
I is widely used commerc
E
-114.3
- 120.2
-CF2- next to XD
F
-120.3
-123.1
-CF2- in
C
-121.5
-124.2
-c f 2-c f 2-c f 2-
H -122.3
-CF2- next to branch points
ties. For example, tb the treatment of fabrl production of waxed pa (12). The findings pc organic fluorine was n ic fluoride either in the earlier finding th in the blood of animal
I
-126.0
-127.6
-CF2- next to
terminal -CF3
with environmental sou The prevalence of
probably quite high al
^External referencing to CFClj was used for the chemical shifts, and these are expressed with positive numbers
. to lower field (i.e., higher frequency), where X is likely to be -CO-Y
here and all 35 in an Th prevalence of the terized here, i.e., pe not known since the at figure 4 was pooled fr
since only about one t
content was accounted compounds (see table I
Peaks other than t
chromatograms shown is
contains other forma o
probably not volatile that these would be de this study. They corr since they appear in f
flcatioa step. Accord
! ` * I 111 -t L ^ t l- . J . l t AB CO
l..,
E FGH I
Figure 5. NM R spectrum o f organic ftuorocom pound(s) isolated from human plasm a
that step the first el third eluents contain certain bile a d d s in lanlne and tyrosine, non-lipid compounds Q
BEST COPS AVAILABLE
000113
7. cur e t a l . Fluorocompounds in Human Plasma
131
representing -CF3 groups at branch points, peak C the -CF3 groups two carbons removed from the branch points, and peak H representing -CF2- next to the branch points.
The sample was reanalyzed for organic fluorine following characterization by nmr to check for contamination; no additional fluorine was apparent. The degree to which fluorine from perfluoro-octanoic acid is fixed as Inorganic fluoride during ashing was found to be 21 i 3 SO Z (n3).
Discussion
These findings suggest that there is widespread contamination of human tissues with trace amounts o i organic fluorocompounds derived from commercial products. All available information on this subject is in accordance with this interpretation. A series of compounds having a structure consistent with that found here for'the predominant form of organic fluorine in human plasma is widely used commercially for their potent surfactant proper ties. For example, they are used as water and oil repellents~in the treatment of fabrics and leather. Other uses include the .production of waxed paper and the formulation of floor waxes (12)1 The findings presented here that the concentration of organic fluorine was not related to the concentration of inorgan ic fluoride either in blood or in the public water supply, and the earlier finding that there was little or no organic fluorine in the blood of animals other than human (6) are all in keeping with environmental sources such as these.
The prevalence of organic fluorine in human plasma is probably quite high since 104 of the 106 plasma samples tested here and all 35 in an earlier study (5) had measurable quantities. The prevalence of the particular compounds Isolated and charac terized here, i.e., perfluoro fatty aci4 (Cg-Cg) derivatives, is not known since the starting material for each batch shown in figure 4 was pooled from between 25 and 30 individuals and since only about one third of the original organic fluorine content was accounted for in the fractions containing these compounds (see table III).
Peaks other than the one characterized by nmr appear in the chromatograms shown in figure 4 suggesting that human plasma contains other forms of organic fluorocompounds. They are probably not volatile compounds like freons since it is doubtful that these would be detected by the analytical methods used in this study. They correspond in solubility to very polar lipids since they appear in fractions two and three in the fourth puri fication step. According to the authors of the method used in that step the first eluent contains most fats, the second and third eluents contain very polar fats like gangllosides and certain bile a d d s in addition to compounds like urea, phenyla
-I lanine and tyrosine. The last fraction contains water soluble
non-lipid compounds (11). Components of these other peaks are
RL001554
EID107126
000114
132
BIOCHEMISTRY INVOLVING CARBON-FLUORINE BONDS
less polar than the compounds in the predominant peaks in accordance with the methanol-in-chloroform gradient used to elute them in the fifth purification step. Other forms not seen in silicic acid fractions may also exist since only about half the original organic fluorine was recovered in these fractions.
The actual amounts of the perfluorinated fatty acid derivatives in human plasma is not known both because individual plasma samples were not assayed for these particular compounds and because the degree to which organic fluorine from these compounds is converted to inorganic fluoride during ashing is not known. Metal salts of perfluorinated fatty acids have been reported to decompose at 175 to 250* C forming COj, volatile perfluorinated olefins one carbon shorter, and one atom of fluoride per molecule (13). About 3 fluorine atoms per molecule of perfluoro-octanolc acid were fixed as Inorganic fluoride by ashing methods used here. Thus, values reported here for fluoride after ashing fractions from the major peaks in figure 4 probably represent somewhere between one-third and one times the molar amount.
Little has been published about the metabolic handling and toxicology of perfluorinated fatty acid derivatives. Computer" assisted literature searches using Medline, Toxline and Chemcon developed no information on these subjects. This was surprising with respect to the widespread commercial use of such compounds. it would appear from Information presented here that rapid excretion of such compounds into urine is unlikely since they are bound to albumin in the blood. On this topic it can also be stated that other chemicals are usually not toxic in blood con centrations similar to those found here for organic fluorine.
The concentration of organic fluorine in human plasma may be changing with time. In 1960 Singer and Armstrong reported that the plasma of 70 *individuals residing in communities with 1 ppm or less fluoride in their public water supply had an average concentration of fluoride of 8.8 pM. (8). They prepared their samples by ashing them and then distilling fluoride from the ash acidified with perchloric acid (7 ). Thus, it seems likely that their values for "fluoride" would have included organic fluorine had it been present. Assuming chat inorganic fluoride concentrations at that time were similar to those found in this study (see table II), the organic fluorine component would exceed 7 pM. In 1969 the same investigators using the same method reported an average fluoride concentration of 4.5 pH for 6 plasma samples each pooled from at least 3 individuals supposedly living in fluoridated communities (14). This corresponds to an organic fluorine component of only about 4 pM. Organic fluorine concentration presented here averages only 1.35 pH. Therefore, there may have been a decrease in the concentration of organic fluorine in human plasma since the late 1950's. An alternate explanation slight be that differences in
i
i $
i
cu r e t a l . Fluorocompounds in Human Plasma
133
the analytical methods or differences in the sample populations caused these values to vary.
Organic fluorine is the predominant form of fluorine in human blood except where the concentration of fluoride in drinking water is high (in which case fluoride predominates, see table II). This together with the finding reported here that there is no apparent relationship between the concentrations of organic fluorine and Inorganic fluoride in plasma helps explain why in earlier studies (8) no relationship was found between plasma fluoride determined in ashed samples and the fluoride content of the public water supply. The data in table II show that when methods specific for inorganic fluoride are applied, a clear relationship between fluoride in plasma and fluoride in the public water supply (between 0.1 and 5.6 ppm) can be demonstrated. Thus, there is no need to postulate the existence of such rigorous homeostatic control mechanisms for plasma fluoride as suggested earlier (8). Average plasma fluoride concentrations for Individuals living in the same city as reported here reflect the balance established between fluoride in blood and that in bone mineral over periods of years. These findings do not contradict a passive homeostatic control mechanism in which bone mineral damps swings in blood fluoride concentration over relatively shorter periods of time.
The values presented here for the average Inorganic fluoride concentration of plasma from individuals living in a community having about 1 ppm fluoride in the water supply are consistent with recent findings of others using similar methods (14. 15).
Literature Cited 1. Taves, D.R.,Nature (1966), 211. 192. 2. Taves, D.R.,Nature (1968), 217. 1050. 3. Taves, D.R., Nature (1968), 200. 582. 4. Taves, D.R., Talanta (1968), 15. 1015. 5. Guy, W.S., "Fluorocompounds of Human Plasma: Analysis,
Prevalence, Purification and Characterization", doctoral thesis, University of Rochester, Rochester, N.X., 1972. 6 . Taves, D.R., J. Dental Res. (1971), 50, 783. 7. Singer, L. and Armstrong, V.D., Anal. Chem. (1959), 31, 105. 8. Singer, L. and Armstrong, W.D., J. Appl. Physiol. (1960), 15. 508. 9. Taves, D.R., Talanta (1968), 15. 969. 10. Frant, M.S. and Ross, Jr., J.W., Science (1966), 154. 1553. 11. Slakotos, A.N. and Rouser, G., J. Amer. Oil Chen. Soc. (1965)
42, 913. 12. Bryce, H.C., "Industrial and Utilitarian Aspects of Fluorine
Chemistry" in "Fluorine Chemistry", Vol. V, J.H. Simon, ed., Academic Press, N.Y., 1964. 13. Hals, L.J., Reid, T.S. and Smith, C.H., J. Amer. Chem. Soc.
(1951), 73, 4054. 14. Singer, L. and Armstrong, V.D., Arch. Oral Bio.(1969),14,1343. 15. Singer, L. and Armstrong, V.D., Blochcm. Med. (1973), 8, 415.
Vi
RL001556
EID107128
000116
1S4
BIOCHEMISTRY INVOLVIXC CAHBON-FU'ORINE BONDS
Q. I wonder if you tried to correlate within individuals the level of organic fluorine with age. A. It would certainly be interesting to have this information but unfortunately we cannot supply it at this time. An expedi tious approach might be to analyze cord blood from infants of mothers who had not received fluorine-containing anesthetics at childbirth. It would also be of interest to know whether individuals living in isolated regions have organic fluorine in their blood plasma. Q. Did you say the sample analyzed by nmr contained methyl alcohol? A. Yes, I did. Q. Methyl alcohol will react very rapidly with fluorlnated acids. The nmr spectrum may, therefore, represent that of methyl ester derivatives. A. Methanol was also used in the last three steps of the purification system. The nmr spectrum is consistent with the presence of methyl ester derivatives of perfluorinated fatty acids (Cg-Cg) and their branched Isomers.
EID107129