Document X7vaO5ZMLRBznRZ4Zxapd8y7J
iScience
c Cellpress OPEN ACCESS
Article
Enteral liquid ventilation oxygenates a hypoxic pig model
Tasuku Fujii, Yosuke
Yoneyama, Akiko Kinebuchi, Hiroshi Date, Kimitoshi Nishiwaki, Takanori Takebe
@cchmc.org
Highlights Enteral liquid ventilation oxygenates independent of native lung function
Early oxygen transfer dynamics inversely correlate with baseline oxygenation status
Enteral liquid ventilation reduced the partial pressure of carbon dioxide
Oxygenation commences from the venous outflow of the large bowel
Fujii et al., iScience 26, 106142 March 17, 2023 2023 The Authors. https://doi.org/10.1016/ j.isci.2023.106142
iScience
c CelPress OPEN ACCESS
Enteral liquid ventilation oxygenates a hypoxic pig model
Tasuku Fujii,1 Yosuke Yoneyama,2 Akiko Kinebuchi,2 Naoki Ozeki,3 Sho Maeda,1 Norikazu Saiki,2 Toyofumi Fengshi Chen-Yoshikawa,3 Hiroshi Date,4 Kimitoshi Nishiwaki,1 and Takanori Takebe2,5A7,8,*
SUMMARY
The potential of extrapulmonary ventilation pathways remains largely unexplored. Here, we assessed the enteral ventilation approach in hypoxic porcine models under controlled mechanical ventilation. 20 mL/kg of oxygenated perfluorodecalin (O2-PFD) was intra-anally delivered by a rectal tube. We simultaneously monitored arterial and pulmonary arterial blood gases every 2 min up to 30 min to determine the gut-mediated systemic and venous oxygenation kinetics. Intrarectal O2-PFD administration significantly increased the partial pressure of oxygen in arterial blood from 54.5 6.4 to 61.1 6.2 mmHg (mean SD) and reduced the partial pressure of carbon dioxide from 38.0 5.6 to 34.4 5.9 mmHg. Early oxygen transfer dynamics inversely correlate with baseline oxygenation status. SvO2 dynamic monitoring data indicated that oxygenation likely originated from the venous outflow of the broad segment of large intestine including the inferior mesenteric vein route. Enteral ventilation pathway offers an effective means for systemic oxygenation, thus warranting further clinical development.
INTRODUCTION
For progressive respiratory failure, oxygen therapy can save the patient's life. However, approximately onequarter of hospitals surveyed in resource-limited countries lack sufficient oxygen supply.1 This limitation is becoming more obvious with recent COVID-19 pandemic as patients regularly require interhospital transport for diagnostic or therapeutic purposes accelerated by hospital overcrowding. Although there are transient oxygen delivery methods available, several major limitations are important to take into account. For example, patients are at risk for severe respiratory distress or exhaustion due to increased breathing load.2 Therefore, a simple and less invasive lung-independent respiratory support is highly demanding particularly in areas with resource-poor settings.
Historically, extrapulmonary oxygenation routes involving the gastrointestinal (GI) tract have been clinically explored. In the 1950s, for example, gastric gas insufflation was tested to treat asphyxia in newborns.3-7 However, the effectiveness of enteral ventilation therapy remains widely debated.8 Several groups recently revisited the potential of the enteral route for the systemic delivery of oxygen. Using a liquid solvent called perfluorocarbons with extraordinary oxygen solubility, Okabe et al. showed that intrarectal administration of oxygenated perfluorocarbons led to systemic oxygenation in animals with respiratory failure.9 Another preprint study by Mountford et al. demonstrated that delivering oxygen microbubbles increased systemic blood oxygen levels in smoke-inhaled hypoxic pig models.1 While the methods above seem promising, GI-mediated systemic oxygenation is compounded by the recipient's remaining lung function. Therefore, it is imperative to understand parameters that influence the gas exchange efficiency and exclude lung contribution to determine the gut-mediated oxygenation potential.
Herein, we evaluated the effectiveness of the enteral ventilation approach under controlled mechanical ventilation. To dissociate contributions from native lung function, we applied a muscle relaxant in a stable hypoxic minipig model. We investigated whether GI-mediated systemic oxygenation is delivered exclusively from the gut or whether the impact is combined with improved native lung function. Arterial pressure, pulmonary arterial pressure, oxygen saturation (SpO2), heart rate, blood temperature, and mixed venous oxygen saturation (SvO2) were continuously monitored. The objective of this study was to evaluate the extrapulmonary ventilation pathway in a large animal model to set the stage for future clinical development.
'Department of Anesthesiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan
'Institute of Research, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima Bunkyo-ku, Tokyo 113-8510, Japan
'Department of Thoracic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan
Department of Thoracic Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
'Division of Gastroenterology, Hepatology & Nutrition, Developmental Biology, Center for Stem Cell and Organoid Medicine (CuSTOM). Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH 45229-3039, USA
Department of Pediatrics, University of Cincinnati College of Medicine, 3333 Burnet Avenue, Cincinnati, OH 45229-3026, USA
7Premium Research Institute for Human Metaverse Medicine (WPI-PRIMe), and Division of Stem Cell and Organoid Medicine, Osaka University, Suita, Osaka 5650871, Japan
'Lead contact
*Correspondence: (0cchmc.org
https://doi.org/10.1016/j.isci. 2023.106142
O
iScience 26, 106142, March 17, 2023 2023 The Authors.
1
This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
ll
OPEN ACCESS
A
C
B
iScience
Article
Figure 1. Overview of the experimental protocol using enteral ventilation (A) Oxygen loading capacity of PFD. (B) Oxygen retention capability of the oxygen-loaded PFD in an administration bag. (C) Schematic diagram of the experimental protocols. Rectal O2-PFD administration was repeated 3 times, accompanied by collection twice. Data are represented as mean G SD N2, nitrogen; O2, oxygen; O2-PFD, oxygenated perfluorodecalin; min, minutes; PO2, partial pressure of oxygen; SpO2, pulse oximetry; PaO2, partial pressure of oxygen in arterial blood; SaO2, arterial oxygen saturation; SvO2, mixed venous oxygen saturation; SivcO2, oxygen saturation of the inferior vena cava; SpvO2, oxygen saturation of the portal vein.
RESULTS The experimental outlines are illustrated in Figure 1. The profiles of the nine pigs are summarized in Table 1. We used two differently sized pigs in our experiments to evaluate whether body weight affects the oxygenation effect. In addition, we conducted experiments to confirm the local oxygenation using normal-sized pigs due to the practicality of portal vein cannulation. To introduce hypoxia, FiO2 was set at 0.11-0.15. At baseline, SaO2, PaO2, and PaCO2 were 82.5G7.3%, 54.5G6.4mmHg, and 38.0G5.6 mmHg, respectively. Other parameters such as body temperature and blood pressure that might affect the oxygenation curve were carefully controlled throughout the procedures. We bubbled pure oxygen gas into the perfluorodecalin (PFD) liquid to load oxygen into PFD. The partial pressure of oxygen in PFD reached near saturation (760 mmHg) 5 min after the bubbling (Figure 1A). Oxygen levels in PFD were retained at high levels (>650 mmHg) for one week in an administration bag (Figure 1B). Intrarectal administration of oxygenated PFD (O2-PFD) was repeated three times in each pig, and 27 experiments were performed.
Correlative factors for oxygenation Throughout the experiments, immediate oxygenation response was detectable after O2-PFD administration in minipigs. Therefore, we first evaluated the early oxygenation dynamics, noting that oxygen transfer peaked around the first 4 min. Mean 4 min-increase in SvO2, SaO2, and PaO2, from the baseline was +4.56%, +3.65%, and +3.60 mmHg, respectively. We next explored the correlation between
2 iScience 26, 106142, March 17, 2023
iScience
Article
ll
OPEN ACCESS
Table 1. Baseline characteristics of hypoxic minipigs before O2-PFD administration
female minipigs (n=7)
female pigs (n=2)
Weight (kg)
24.2 G 2.0
42.4 G 0.8
Mean arterial blood pressure (mmHg)
111 G 18
79 G 6
Heart rate (beat/min)
123 G 16
164 G 4
Blood temperature (C)
34.4 G 0$9
34.3 G 0.1
Cardiac output (L/min)
1.6 G 0.7
4.3 G 0.2
Use of vasopressor Epinephrine Phenylephrine
5 (71%) 3 (43%)
2 (100%) 0 (0%)
FiO2
0.13 [0.12-0.15]
0.12 [0.11-0.12]
PEEP (mmHg)
10 [10-10]
10 [10-10]
Respiratory rate (breaths/min)
10 [8-10]
10 [10-10]
SpO2 (%)
84.9 G 4.8
83.0 G 0.0
SaO2 (%)
82.9 G 11.9
81.6 G 0.5
PaO2 (mmHg)
62.7 G 12.5
50.4 G 0.6
PaCO2 (mmHg)
38.9 G 4.0
40.1 G 0.6
Values are presented as mean G SD, median [IQR], or number (proportion). Abbreviations: FiO2, fraction of inspiratory oxygen; IQR, interquartile range; O2-PFD, oxygenated perfluorodecalin; PaCO2, partial pressure of carbon dioxide in arterial blood; PaO2, partial pressure of oxygen in arterial blood; PEEP, peak end-expiratory pressure; SaO2, arterial oxygen saturation; SD, Standard Deviation SpO2, pulse oximetry.
time-evolving oxygenation parameters (at 2, 4, 8, and 12 min after the administration) and the pre-treatment gas parameters to understand the variables for defining oxygen transfer efficiency. All the Pearson correlation coefficients are shown in Figure S1A. For example, the baseline PaO2 level showed an inverse correlation with a 4 min-increase in arterial oxygenation (delta (D)PaO2 4min) with a correlation coefficient of 0.475. When we limit the baseline PaO2 level to 4565 mmHg, its linearity improves to 0.740. Notably, of all the tested parameters, the baseline SvO2 was most closely correlated with the transfer of oxygen, with a linear correlation coefficient of 0.728 with DSaO2 4min of O2-PFD administration (Figure S1B). These results indicate the enteral ventilation effect starts as early as 2-4 min, and its potency is inversely associated with prior oxygenation status, particularly at the level of the vein.
Peaked impacts on O2 uptake and CO2 removal We next determined the time-course dynamics of each gas parameter every 2 min in minipigs. The enteral ventilation effect to improve oxygenation was sustained for up to 30 min until PFD was removed from the gut (Figure 2A), while respiratory rate and minute ventilation volume remained unchanged (Figure 2B). The maximum effect on systemic oxygenation was 88.2 G 5.4% compared to the baseline of 82.5 G 7.3 (p < 0.001) for SaO2. PaO2 also increased from 54.5 G 6.4 to 61.1 G 6.2 mmHg (p < 0.001), indicating the resolution of the induced respiratory failure conditions (Figure 3A). Given that PFD dissolves significant amounts of most gases, including carbon dioxide, typically in the 120250 vol % range, i.e., 3-5 times more than oxygen, we tested if enteral O2-PFD has effects on carbon dioxide removal. Interestingly, PaCO2 was significantly reduced throughout the experiment: 38.0 G 5.6 at the baseline and 34.4 G 5.9 mmHg at postO2-PFD administration (p < 0.001) (Figure 3B). In particular, the increase in oxygenation showed a higher trend in mixed venous blood than in arterial blood throughout treatment (3.4 G 5.5% in DSaO2 versus 4.9 G 6.3% in DSvO2, at 8 min after O2-PFD infusion, p = 0.082), suggesting that the oxygen uptake precedes the arterial oxygenation via venous route.
Such systemic ventilatory effects were rapidly reversed upon removal of the enteral PFD in 30 min. To assess the changes in the dissolved oxygen and carbon dioxide in PFD, we measured the partial pressure of the collected PFD. The oxygen partial pressure was significantly lower after 30 min of administration (from 688 G 36 to 395 G 96 mmHg after collection; p < 0.001), whereas the carbon dioxide partial pressure was increased (3.4 G 1.1 to 15.0 G 6.2 mmHg after collection; p < 0.001) (Figures 3C and 3D). Conversely, SaO2 decreased from 89.0 G 5.0% to 81.2 G 7.9% (p < 0.001), and PaO2 decreased from 61.1 G 6.5 to
iScience 26, 106142, March 17, 2023 3
ll
OPEN ACCESS
A
B
iScience
Article
Figure 2. Systemic oxygenation and ventilation effects of enteral ventilation after O2-PFD administration and removal (A) Changes in time series of SaO2, SvO2, PaO2, and PaCO2. (B) Time series changes in minute ventilation and respiratory rate. The ventilator was set to mandatory mode with a tidal volume of 8-10 mL/kg and a respiratory rate of approximately 35 mmHg for end-tidal carbon dioxide. The peak endexpiratory pressure (PEEP) was set at 8-10 mmHg. Delta represents the difference in blood gas analysis and respiratory monitoring values before and after O2-PFD administration. The red, black, blue, and pink lines represent the mean values of PaO2, SaO2, SvO2, and PaCO2, respectively in (A). Each shaded area represents the 95% confidence interval. O2-PFD, oxygenated perfluorodecalin; SaO2, arterial oxygen saturation; SvO2, mixed venous oxygen saturation; PaO2, partial pressure of oxygen in arterial blood; PaCO2, partial pressure of carbon dioxide in arterial blood; RR, respiratory rate; MV, minute ventilation.
53.6 G 7.0 mmHg (p < 0.001), while PaCO2 increased from 34.8 G 5.9 to 37.9 G 6.7 mmHg (p < 0.001). The post-retrieval trend of rapid oxygen reduction was similar to the change at the time of O2-PFD administration (Figure 2A). These results indicate that oxygen and carbon dioxide were exchanged by enteral exposure to PFD.
Venous oxygenation through the distal intestine Inspiratory and exhaled oxygen concentrations were stabilized before the administration of O2-PFD. Respirator settings remained unchanged throughout the procedures (Figure 2B) and inspiratory oxygen concentration was consistent (FiO2, from 12.9 G 1.7% to 13.0 G 1.7% (p = 0.164)). However, the exhaled oxygen concentration was increased from 8.1 G 1.3% (baseline) to 8.9 G 1.4% (maximum) (p < 0.001) following the administration of O2-PFD. The resultant difference between inspiratory and exhaled oxygen concentration reduced from 4.8 G 0.9% to 4.1 G 0.9% (p < 0.001). A significant increase in exhaled oxygen concentration indicates that enteral ventilation might oxygenate via returning, i.e., venous, circulatory route.
To further explore how enteral ventilation impacts venous oxygenation dynamics in blood at different anatomical levels, we performed the gas analysis of the pulmonary artery, IVC, and portal vein, before and after treatment in normal-sized pigs (Figure 4A). Colorectal venous drainage systems are governed by the superior, middle, and inferior rectal (hemorrhoidal) veins. The superior rectal and inferior mesenteric veins drain into the portal vein, passing the blood through the liver before reaching the systemic circulation. In contrast, the inferior and middle rectal veins drain into the inferior vena cava and, therefore, directly into the systemic circulation, which is approximately responsible for 50% of suppository drug absorption.11 Consequently, we determined the contributions of venous oxygenation at the level of the portal vein and the infrarenal level of IVC. At 15 min after O2-PFD infusion, SpvO2 has increased from 55.5 G 5.9% (baseline) to 68.9 G 4.3% whereas SivcO2 increased from 62.1 G 2.9% (baseline) to 68.6 G 5.1%. The oxygenation effect at 15 min DSpvO2 in the portal vein relative to DSivcO2 was 13.4 G 7.9% vs. 6.5 G 3.6% (p = 0.033) (Figure 4B). Interestingly, the venous oxygen saturation in both the portal vein and inferior vena cava showed upward trends until 14 min and then gradually declined while sustained higher level than the baseline (Figure 4B), indicating local oxygen imbalance between supply and consumption occurred in
4 iScience 26, 106142, March 17, 2023
iScience
Article
A
B
C
D
ll
OPEN ACCESS
Figure 3. Changes in the partial pressure of oxygen and carbon dioxide before and after enteral ventilation (A) Maximum changes in PaO2. (B) Maximum changes in PaCO2. (C) Changes in PO2 of O2-PFD. (D) Changes in PCO2 of O2-PFD. The box and whisker plots (min to max) are shown. Colored dots represent data from the same pig to show within-/between-animal variations. The p values were calculated using a paired t-test. *p < 0.001. O2PFD, oxygenated perfluorodecalin; PaO2, partial pressure of oxygen in arterial blood; PaCO2, partial pressure of carbon dioxide in arterial blood; PO2, partial pressure of oxygen; PCO2, partial pressure of carbon dioxide.
14-16 min. Thus, enteral ventilation delivers oxygen through the venous system leading to systemic oxygenation in the arterial system.
Adverse events The gross examination showed no signs of colorectal damage or perforation after repeated dosing. Consistently, histopathological examination revealed no damage or inflammation to the rectal mucosa due to PFD (Figures S2A-SC). In addition, no macrophages that phagocytized PFD were observed in the spleen (Figures S2D and S2E).
During enteral ventilation under hypoxia, hemodynamics studies showed that mean arterial pressure increased and pulse rate decreased significantly. Maximal vital sign changes induced by O2-PFD administration ranged from 115 G 27 to 129 G 26 mmHg (p < 0.001) in the mean arterial pressure
iScience 26, 106142, March 17, 2023 5
ll
OPEN ACCESS
A
B
iScience
Article
Figure 4. Differences in the effect of oxygenation by enteral ventilation between venous and arterial blood after O2-PFD administration (A) A schematic diagram of the venous blood sample at different anatomical levels. (B) Effect of oxygenation in each blood. Delta represents the difference in blood gas analysis values before and after O2PFD administration. The red, black, and blue lines represent the mean values of SpvO2, SivcO2, and SvO2, respectively. Each shaded area represents the 95% confidence interval. O2-PFD, oxygenated perfluorodecalin; IVC, inferior vena cava; PV, portal vein; SivcO2, oxygen saturation of the inferior vena cava; SpvO2, oxygen saturation of the portal vein; SvO2, mixed venous oxygen saturation.
(MAP) and 117 G 17 to 112 G 14 beats/min (p = 0.002) in the pulse rate. After retrieval of the O2-PFD from the intestine, the mean blood pressure and pulse rate almost returned to that observed before O2-PFD administration (Figure S3). It is not clear whether MAP increase effect is due to an oxygenating effect or an effect of an increased venous return. Thus, despite severe hypoxia, the animals did not undergo shock, and, in fact, the mean arterial pressure increased by an average of approximately 10 mmHg.
DISCUSSION Our study, using hypoxic pig models with a combination of approved medical devices and a clinically feasible dose of O2-PFD, provides definitive proof that enteral ventilation is possible, independent of the effect of native lung respiration. Initial oxygen transfer and carbon dioxide reduction started within 2 min of O2-PFD administration and sustained blood gas status until PFD was removed at 30 min. SvO2 dynamic monitoring data indicated that oxygenation most likely started from the venous outflow of the gut, as expected. We also found an increase in oxygen in the portal vein, suggesting potential uptake through the broader large intestine and the inferior mesenteric vein route, even above the level of the rectum. Therefore, extrapulmonary respiration induces systemic oxygenation through venous oxygenation.
Among aquatic organisms that utilize GI as extrapulmonary respiratory organs, the loach has a gas exchange function in its hindgut (distal intestine).12,13 Such gut air-breathing (GAB) species use their gastrointestinal system to maintain systemic oxygenation under respiratory distressed conditions.14 Though precise mechanisms for hypoxia acclimation are unclear, aerial ventilation in GAB fishes is driven primarily by oxygen partial pressure of the water (PO2).14 For example, the onset of aerial respiration occurred at inspired oxygen tensions (PiO2) between 50 and 60 mmHg, and breathing frequency is linearly increased to 25 mmHg without significant hypometabolic change in Hypostomus regani.15 Our pig study similarly suggested that the prior hypoxic state influences the mammalian ventilatory effect. Indeed, the oxygen transfer efficiency linearly upregulated in the range of 45-65 mmHg PaO2. In support, several reports of intestinal16 or peritoneal17 perfusion of oxygenated perfluorocarbon, albeit with incremental (-hourly) effectiveness, discussed that the most effective oxygenation was achieved at a pre-treatment PaO2 level of around 40-60 mmHg.
6 iScience 26, 106142, March 17, 2023
iScience
Article
Interestingly, the correlation coefficient analysis indicates that the SvO2 baseline is inversely associated with systemic oxygenation efficiency relative to pre-treatment arterial oxygenation status. This is in line with our mechanistic expectation since O2-PFD is initially exposed to venous circulation via the intestinal mucosa, thereby directly affecting oxygen transfer. Perfluorocarbon-dissolved O2 is immediately available to deliver into hemoglobin by diffusion-based mechanisms.18 With the intact intestinal epithelial cells, our experimental data favor that diffusion-based oxygen transfer into hemoglobin is a mechanism for the venous oxygen increase. Thus, ventilatory drive in mammalian enteral breathing likely involves recipient oxygenation status and should be considered when developing a clinical application for diseases of hypoxia.
Oxygen carriers for enteral ventilation include oxygen gas, oxygen microbubbles, and perfluorocarbons. Previous studies showed oxygen gas infusion requires mucosal damage to deliver sufficient oxygen9 and, therefore, is unacceptable for humans. While oxygenated microbubble infusion is effective when given as a relatively high-dose bolus injection (i.e., 75-100 mL/kg: 3,750-5,000 mL for 50 kg),10 the perfluorocarbon approach can deliver the benefit with modest, repeated, dosing (i.e., 20 mL/kg: 1000 mL for 50 kg). This injection volume has been within dosage readily approved for human enterography procedures in single-contrast technique. In this study, O2-PFD has been slowly infused by drop from a height within 50 cm to prevent a substantial increase in intrarectal pressure. However, the effects of O2-PFD on humans are unknown. Therefore, preclinical studies are planned to confirm the tolerability of intrarectal PFD in humans. Of the perfluorocarbon compounds, we elected to use perfluorodecalin (PFD), a perfluorocarbon already extensively used in animals9 and human studies involving blood substitutes, liquid breathing, eye surgery,19 and known for its extraordinary oxygen and carbon dioxide dissolving capacities. Consistent with the reported safety of PFD in humans, enteral O2-PFD exposure is safe and tolerable without significant complications such as colorectal perforation, bacterial translocation, or liver dysfunction.
Intrarectal bolus infusion of O2-PFD can be operated without a specialized respiratory care team even in resource-limited settings. Such affordable technique will provide a supplemental way to oxygenate until advanced medical care is available as a bridging therapy. Some potential scenarios include the prehospital transport, emergency, or the preparatory settings for the invasive respiratory support.
Limitations of the study This study, however, has a few limitations. First, the observation was confined for up to 30 min; therefore, the duration of efficacy and cumulative risk is unclear. Second, PFD dose-dependent effect was not tested. Third, respirator settings remained constant throughout the procedures, precluding the assessment of the crosstalk between intra- and extrapulmonary respirations effects. Finally, since this study was carried out in pigs under general anesthesia and muscle relaxant, tolerability under an awake status requires future evaluation. Nevertheless, our present study, conducted using a combination of clinically relevant medical devices, including PFD and a rectal balloon tube, firmly supports the therapeutic potential of extrapulmonary ventilation. Further preclinical and clinical development of the enteral ventilation approach is warranted.
STAR+METHODS Detailed methods are provided in the online version of this paper and include the following:
d KEY RESOURCES TABLE d RESOURCE AVAILABILITY
B Lead contact B Materials availability B Data and code availability d EXPERIMENTAL MODEL AND SUBJECT DETAILS B Animals B Hypoxia model d METHOD DETAILS B Anesthesia, maintenance, and monitoring B Enteral ventilation and blood gas analysis B Outcome measurements d QUANTIFICATION AND STATISTICAL ANALYSIS
ll
OPEN ACCESS
iScience 26, 106142, March 17, 2023 7
ll
OPEN ACCESS
iScience
Article
SUPPLEMENTAL INFORMATION Supplemental information can be found online at https://doi.org/10.1016/j.isci.2023.106142.
ACKNOWLEDGMENTS The authors would like to thank Vivian Hwa for her critical reading of the manuscript and Kunihiko Takahashi for statistical advice. Illustrations were created using Biorender.com. We also appreciate Asuka Kodaka for generating graphical abstract. We appreciate Ryo Okabe, Shogo Nagata, Yasuyuki Kurihara, Koichi Fukumoto, Koichi Masuda, Asuka Kodaka, Masashi Takakura, Osamu Mitani, Yoshiro Yamamura, and the laboratory of IVTeC Co., Ltd. for technical assistance with the experiments, and experts at EVA Therapeutics, Inc., Mune Pharmaceutical Co., Ltd., and Maruishi Pharmaceutical Co., Ltd. for professional advice over the PFD manufacturing and preclinical study design. We also thank Mari Maezawa, Noriko Yokota, Michiko Mori, and all other Takebe Lab members for administrative and intellectual assistance.
This work was supported by funding from AMED for the Research Projects on COVID-19 (JP20fk0108278, 20fk0108506h0001, 21fk0108491h0001), and JSPS KAKENHI Grant Number JP21H04822. This work is also generously supported by a philanthropic gift from Mr. Hajime Kawakami and 263 anonymous and non-anonymous supporters through Readyfor crowdfunding, including Yanaizuaoyama Ophthalmology Clinic (Masaru Aoyama), Sonshin Takao, Kanyou Tanoue, Nacalai Tesque, Inc., Natsuko Sugiyama, Toyofumi Fengshi Chen-Yoshikawa, whynofundsfromG, Akira Imamura, Furutani Sangyou Co., Ltd. (Yoshiyasu Furutani), Tomoko Okabe, Hirotake Uchikado, Tei Ken, Takamasa Mikami, Taishi Tagawa, Noriko Mizuguchi, Reiko Tagawa, Namiko Sakai, Taro Asakura, Akari Sugiyama, Hideo Takahashi, RIKAKEN, Co., Ltd., Yuriko Oka, and Masaki Fukuda.
AUTHOR CONTRIBUTIONS T.F., Y.Y., T.F.C.-Y., K.N., and T.T. designed the experiments; T.F., Y.Y., A.K., N.O., S.M., T.F.C.-Y., and K.N. performed the experiments; T.F. and T.T. wrote the first draft of the manuscript; all authors discussed the results and contributed to the final manuscript.
DECLARATION OF INTERESTS Y.Y., T.F.C.-Y., and T.T. are inventors for enteral ventilation and founder of EVA Therapeutics, Inc. T.F. and Y.Y. are scientific advisors for EVA Therapeutics, Inc.
INCLUSION AND DIVERSITY We support inclusive, diverse, and equitable conduct of research.
Received: August 16, 2022 Revised: November 11, 2022 Accepted: February 1, 2023 Published: February 13, 2023
REFERENCES 1. Meara, J.G., Leather, A.J.M., Hagander, L.,
Alkire, B.C., Alonso, N., Ameh, E.A., Bickler, S.W., Conteh, L., Dare, A.J., Davies, J., et al. (2015). Global Surgery 2030: evidence and solutions for achieving health, welfare, and economic development. Lancet 386, 569-624. https://doi.org/10.1016/S01406736(15)60160-X.
2. Dondorp, A.M., Hayat, M., Aryal, D., Beane, A., and Schultz, M.J. (2020). Respiratory support in COVID-19 patients, with a focus on resource-limited settings. Am. J. Trop. Med. Hyg. 102, 1191-1197. https://doi.org/10. 4269/ajtmh.20-0283.
3. Barrie, H. (1959). Intragastric administration of oxygen. Lancet 1, 884-885. https://doi. org/10.1016/s0140-6736(59)91963-4.
4. Chajecka-Paszkiewicz, M. (1954). [Intragastric administration of oxygen in asphyxia neonatorum and collapse of prematures]. Pol. Tyg. Lek. 9, 1382-1385.
5. Erecinski, K., and Mieroslawski, W. (1958). [Treatment of asphyxia of the newborn with the rectal administration of oxygen]. Minerva Med. 49, 2675-2678.
6. James, L.S., Apgar, V.A., Burnard, E.D., and Moya, F. (1963). Intragastric oxygen and resuscitation of the newborn. Acta Paediatr. 52, 245-251. https://doi.org/10.1111/j.16512227.1963.tb03777.x.
7. Virasoro, J.E., Pellerano, J.C., and Bertelli, S.A. (1959). [Intragastric oxygen therapy: practical technic for administration in the newborn infant]. Sem. Med. 114, 640-641.
8. Waller, H.K., and Morris, D. (1953). Resuscitation of the newborn with intragastric oxygen; Akerren's method. Lancet 265, 951-953. https://doi.org/10.1016/s01406736(53)90617-5.
9. Okabe, R., Chen-Yoshikawa, T.F., Yoneyama, Y., Yokoyama, Y., Tanaka, S., Yoshizawa, A., Thompson, W.L., Kannan, G., Kobayashi, E., Date, H., and Takebe, T. (2021). Mammalian enteral ventilation ameliorates respiratory failure. Med (N Y) 2, 773-783.e5. https://doi. org/10.1016/j.medj.2021.04.004.
10. Mountford, P.A., Leiphrakpam, P.D., Weber, H.R., McCain, A., Scribner, R.M., Scribner, R.T., Duarte, E.M., Chen, J., Borden, M.A., and Buesing, K.L. (2021). Colonic oxygen microbubbles augment systemic oxygenation and CO2 removal in a porcine
8 iScience 26, 106142, March 17, 2023
iScience
Article
ll
OPEN ACCESS
smoke inhalation model of severe hypoxia. Preprint at bioRxiv. https://doi.org/10.1101/ 2021.12.08.466665.
11. Hua, S. (2019). Physiological and pharmaceutical considerations for rectal drug formulations. Front. Pharmacol. 10, 1196. https://doi.org/10.3389/fphar.2019.01196.
12. Jasinski, A. (1973). Air-blood barrier in the respiratory intestine of the pond-loach, Misgurmus fossilis L. An ultrastructural study. Acta Anat. 86, 376-393.
13. McMAHON, B.R., and BURGGREN, W.W. (1987). Respiratory physiology of intestinal air breathing in the teleost fish Misgurnus anguillicaudatus. J. Exp. Biol. 133, 371-393. https://doi.org/10.1242/jeb.133.1.371.
14. Nelson, J.A. (2014). Breaking wind to survive: fishes that breathe air with their gut. J. Fish. Biol. 84, 554-576. https://doi.org/10.1111/jfb. 12323.
15. Mattias, A.T., Rantin, F.T., and Fernandes, M.N. (1998). Gill respiratory parameters during progressive hypoxia in the facultative air-breathing fish, Hypostomus regani (Loricariidae). Comp. Biochem. Physiol. Mol. Integr. Physiol. 120, 311-315. https://doi.org/10.1016/S1095-6433(98) 00034-8.
16. Miyaguchi, N., Nagahiro, I., Kotani, K., Nakanishi, H., Mori, H., Osaragi, T., and Shimizu, N. (2006). Transintestinal systemic oxygenation using perfluorocarbon. Surg. Today 36, 262-266. https://doi.org/10.1007/ s00595-005-3135-z.
17. Carr, S.R., Cantor, J.P., Rao, A.S., Lakshman, T.V., Collins, J.E., and Friedberg, J.S. (2006). Peritoneal perfusion with oxygenated perfluorocarbon augments systemic oxygenation. Chest 130, 402-411. https://doi. org/10.1378/chest.130.2.402.
18. Riess, J.G. (2006). Perfluorocarbonbased oxygen delivery. Artif. Cells Blood Substit. Immobil. Biotechno. 34, 567-580. https://doi.org/10.1080/10731190600973824.
19. CABRALES, P., Va zquez, B.Y.S., NEGRETE, A.C., and INTAGLIETTA, M. (2007). Perfluorocarbons as gas transporters for O2, NO, CO and volatile anesthetics. Transfus. Altern. Transfus. Med. 9, 294-303. https://doi.org/10.1111/j.1778-428X.2007. 00085.x.
iScience 26, 106142, March 17, 2023 9
CeiPress
OPEN ACCESS
STAR*METHODS
KEY RESOURCES TABLE
REAGENT or RESOURCE
Chemicals, peptides, and recombinant proteins Perfluorodecalin
Ketamine Xylazine Isoflurane Rocuronium Adrenaline Phenylephrine Lactated Ringer's Solution Niflece Combination Powder
SOURCE
F2 Chemicals Ltd. Shandong Zhongshan Photoelectric Materials Co., Ltd. Daiichi Sankyo Propharma Co.,Ltd. Bayer Yakuhin, Ltd. Mylan N.V. MSD Daiichi Sankyo Co,Ltd. Kowa Co., Ltd. Otsuka Pharmaceutical Co., Ltd. EA Pharma Co., Ltd.
Experimental models: Organisms/strains mini pig Pig
IVTeC Co. Ltd./Fuji Micra, Inc. IVTeC Co. Ltd./Fuji Micra, Inc.
Software and algorithms GraphPad Prism 9 R version 4.1.2
Graphpad Software R Project
Other anesthesia machine ventilator double-balloon rectal catheter bedside patient monitor multigas analyzer blood gas analyzer pulmonary artery catheter hemodynamic monitor
ACOMA Medical Industry ACOMA Medical Industry Create Medic CO., LTD. Nihon Kohden Corporation Nihon Kohden Corporation Radiometer Medical ApS Edwards Lifesciences Corporation Edwards Lifesciences Corporation
iScience
Article
IDENTIFIER
Cas: 306-94-5
Cas: 1867-66-9 Cas: 7361-61-7 Cas: 26675-46-7 Cas: 119302-91-9 Cas: 51-43-4 Cas: 61-76-7 CID: 56841910 N/A
N/A N/A
https://www.graphpad.com/ https://www.r-project.org
FO-20A Spiritus N/A Life Scope VS, BSM-3592 GF-119P ABL90 FLEX
631F55N
Vigilance II
RESOURCE AVAILABILITY
Lead contact
Further information and requests for resources and reagents should be directed to, and will be fulfilled by
the lead contact, Takanori Takebe I
@cchmc.org)
Materials availability This study did not generate any new materials or reagents.
Data and code availability Data reported in this paper will be shared by the lead contact upon request. This study did not generate new codes. Any additional information required to reanalyze the data reported in this paper is available from the
lead contact upon request.
10 iScience 26, 106142, March 17, 2023
iScience
Article
EXPERIMENTAL MODEL AND SUBJECT DETAILS Animals Experiments in pigs were carried out in the laboratory of IVTeC Co., Ltd. (Kobe, Japan) and were approved by the Association for the Assessment and Accreditation of Laboratory Animal Care International. The experimental protocols (#IVT21-179/IVT22-10) were approved by IVTeC Co. Ltd. Female minipigs (21.2-26.4 kg, n = 7) and female normal-sized pigs (41.6-43.2 kg, n = 2) were fasted for two days and given free access to water. A peroral intestinal irrigator (Niflec, EA Pharma Co., Ltd., Tokyo, Japan) was administered as a laxative two days before the experiment.
Hypoxia model The hypoxic pig model was established by mixing oxygen and nitrogen using a gas flow meter in an anesthesia machine (FO-20A, ACOMA Medical Industry Co., Ltd., Tokyo, Japan). The inspiratory oxygen fraction (FiO2) was adjusted to maintain the pulse oximeter (measuring SpO2) at approximately 85%. Arterial blood gas analysis was initiated 10 min before experimental manipulation to confirm arterial oxygen saturation (SaO2), partial pressure of oxygen in arterial blood (PaO2), and partial pressure of carbon dioxide in arterial blood (PaCO2) were stable.
METHOD DETAILS Anesthesia, maintenance, and monitoring A mixture of ketamine (10 mg/kg, intramuscular), xylazine (2 mg/kg, intramuscular), and isoflurane were used as anesthetics. After tracheal intubation, 2% isoflurane was used to maintain general anesthesia. After administering an intravenous bolus of rocuronium (25 mg), controlled mechanical ventilation was initiated under continuous intravenous rocuronium infusion (100 mg/h) (MSD Co. Ltd, Tokyo, Japan). To maintain the intravenous fluids, Ringer's lactate solution was administered at a dose of 5 mL/kg/h. In the case of pre-experimental hemodynamic instability, a 100 mL Ringer's lactate solution bolus was administered intravenously, and the maintenance fluid dose was increased to 10 mL/kg/h. If hemodynamic instability persisted after fluid loading, phenylephrine and/or epinephrine were continuously administered. Enteral ventilation protocol was initiated after the hemodynamics stabilized for more than 10 minutes.
The hypoxic pigs did not breathe spontaneously under continuous administration of high-dose muscle relaxants and were mechanically ventilated under controlled conditions. The ventilator (Spiritus; ACOMA Medical Industry Co., Ltd., Tokyo, Japan) was set at a tidal volume of 8-10 mL/kg and a respiratory rate of approximately 35 mmHg for end-tidal carbon dioxide. The peak end-expiratory pressure (PEEP) was set at 8-10 mmHg in the 5 head-up position to prevent deterioration of the lung condition, e.g., due to atelectasis. The ventilator settings remained constant throughout all experimental processes.
Catheters were placed in the right carotid and femoral arteries for repeated blood sampling and blood pressure monitoring, respectively. A Swan-Ganz catheter was placed in the pulmonary artery through the right jugular vein under fluoroscopy. In separate experiments, a central venous catheter was placed at the infrarenal level of the posterior vena cava (inferior vena cava [IVC]) under fluoroscopy, and a portal vein catheter was placed under direct guidance via laparotomy.
Arterial pressure, pulmonary arterial pressure, SpO2, heart rate, blood temperature, and mixed venous oxygen saturation (SvO2) were continuously monitored using a bedside patient monitor (Life Scope VS BSM3592, Nihon Kohden Corporation, Tokyo, Japan). Cardiac output was measured intermittently using bolus thermodilution methods through a Swan-Ganz catheter before and after the intervention.
Enteral ventilation and blood gas analysis Perfluorodecalin (PFD) (F2 Chemicals Ltd, Lea Town, Lancashire, UK or Shandong Zhongshan Photoelectric Materials Co., Ltd, Shandong, China) was used as the perfluorocarbon. Oxygenated perfluorodecalin (O2-PFD) was prepared by 3 L/min pure oxygen bubbling for at least 10 min. The oxygen partial pressure of O2-PFD was confirmed to be >600 mmHg before the experiment. Subsequently, a rectal balloon tube (Create Medic Co., Ltd., Yokohama, Japan) was placed in the porcine rectum, and the catheter balloon was inflated and fixed. O2-PFD (20 ml/kg) was administered into the distal intestine by a rectal tube for approximately 2 min. Arterial and pulmonary arterial blood gas analyses were performed simultaneously every 2 min from the start of O2-PFD infusion for 30 min. O2-PFD was retrieved from the intestine through
ll
OPEN ACCESS
iScience 26, 106142, March 17, 2023 11
ll
OPEN ACCESS
a rectal tube 30 min after O2-PFD infusion. Arterial blood gas analyses were performed every 2 min for 10 min after O2-PFD collection. This procedure was repeated three times. The experimental protocol is illustrated in Figure 1.
In an additional experiment, O2-PFD (20 ml/kg) was administered into the distal intestine through a rectal balloon catheter (Create Medic Co., Ltd., Yokohama, Japan). Arterial, IVC, and portal vein blood samples were analyzed simultaneously every 3 minutes for up to 30 minutes after O2-PFD infusion. O2-PFD was collected by spontaneous discharge from the anus. Arterial blood gas analyses were performed every 3 min until 15 min after O2-PFD collection. These procedures were performed twice on each pig.
All blood gas analyses were performed using an ABL90 FLEX blood gas analyzer (Radiometer Medical ApS, Copenhagen, Denmark) equipped with a co-oximeter.
Outcome measurements The effect of systemic oxygenation and ventilation were measured using arterial and pulmonary arterial blood gas analyses. Increases in oxygen saturation (SaO2, SvO2) and arterial partial pressure (PaO2, PaCO2) from baseline before administration of O2-PFD were evaluated. For each blood oxygenation parameter (PaO2, SaO2, SvO2), the correlation between baseline status and oxygenation was assessed at each measurement interval after O2-PFD administration. The oxygen and carbon dioxide partial pressures of PFD were also measured before and after intestinal administration of O2-PFD.
To assess venous oxygenation levels, the portal vein and infrarenal level of IVC blood samples and pulmonary arterial blood samples were analyzed in an additional experiment using normal-sized pigs. Inspiratory oxygen and expiratory oxygen concentrations were measured by monitoring anesthetic and respiratory gases to evaluate oxygen discharge from expiration rather than inspiration (GF-119 Multi-Gas Unit, Nihon Kohden Corporation, Tokyo, Japan).
We used postmortem histopathology to assess whether the intestinal mucosa and spleen were damaged as a side effect of O2-PFD infusion. Vital signs, such as mean arterial pressure and pulse rate, were also monitored during the procedures.
QUANTIFICATION AND STATISTICAL ANALYSIS The baseline characteristics of hypoxic pigs were compared using Student's t test, Mann-Whitney U test, or Fisher exact test. Systemic oxygenation and maximum ventilation effect by blood gas analysis before and after O2-PFD administration was evaluated using a paired t-test. The simultaneous increase in the oxygenation rate in arterial and mixed venous blood from baseline was compared using the Wilcoxon signed-rank test. The Pearson correlation coefficient evaluated the relationship between the pre-treatment condition and blood gas parameters after O2-PFD administration. The difference between inspiratory and exhaled oxygen concentrations was analyzed using a paired t-test. Categorical variables were expressed as numeric values (proportion), and continuous variables were presented as mean G standard deviation (SD) or median (interquartile range [IQR]). Delta (D) represents the difference in blood gas analysis values before and after O2-PFD administration. Statistical significance was set at p < 0.05. All statistical analyses were performed using Graph Pad Prism9 software and R software, version 4.1.2 (The R Foundation for Statistical Computing, Vienna, Austria).
iScience
Article
12 iScience 26, 106142, March 17, 2023