Document O1oxRZD22Ykq8xXzyjMvEdRYK

'Goodrich / Th BFGoodrich Compony Chemical Group 6100 Oak Tree Boulevard Cleveland. Ohio 44131 216-524-0200 November 30, 1979 Mr. Dick Holliday General Foreman PPG Industries Industrial Chemicals Division P.0. Box 1000 Lake Charles, Louisiana 70601 Attached is the VCM-NESHAP survey made for the Vinyl Chloride Safety Association meeting in San Francisco. You are receiving a copy since your company submitted data for the survey. The companies names have been deleted from the information. Please note the companies are coded by number (#) and R refers to the EPA region. Please share this data with other members of your company who might not have received a copy. I attempted to mail the information to people in your company who need this information and I might have missed someone. The survey is certainly not complete since many companies did not reply. At our next meeting, we may want to discuss in more detail the future of this type of survey, I appreciate your cooperation. Yours very truly, GDS/aw Attachments Si 89l63 VCM NESHAP SURVEY - VCM SAFETY ASSOCIATION (3-1-79 - 7-31-79) A. VINYL CHLORIDE PLANTS #R 16 54 ^13 6 16 6 17 9 22 6 X Hours in Compliance Oxychlorination Reactor Incinerator Other Control 99.992 99.993 99.97 100 ? 99 100 100 100 99.97 100 100 Relief Valve Discharges Number Total Lbs Releases Released 1 114 8 33.9 00 00 7 1,931 3 6,282 */i. SL 089164 VCM NESHAP SURVEY - VCM SAFETY ASSOCIATION (3-1-79 - 7-31-79) B. POLYVINYL CHLORIDE PLANT SUSPENSION! Total if R Openings 24 430 34 27 65 181 75 1,091 89 1,173 94 7,876 10 2 257 12 5 110 14 3 - 15 6 - 16 6 4,265 17 9 29 21 3 Reactor Openings % Compliance M-easured C-alculated 100 M 100 M 98 M 98.3 M 99.9 M 99.6 M 99.2 M 77.3 M 44 M 99 M 99.9 M 100.0 H 100 Resin Stripping % Compliance 100 100 98 100 100 100 100 95.4 97 99 91 98.96 96.7 Relief Valve or Manual Discharges Number Number Total Lbs. Reactor Other Released 00 0 2 3 63,643 02 812 2 0 6,064 21 10 ND 15 00 0 1 4 2,420 2 2 3,162 1 3 2,211 2 1 9,800 5 2 1,915 6 2 4,665 SL 089165 VCM NESHAP SURVEY - VCM SAFETY ASSOCIATION (3-31-79 - 7-31-79) B. POLYVINYL CHLORIDE PLANT DISPERSION Total R Openings 65 7,185 75 1,984 10 2 996 14 3 - 15 6 - 16 6 2,044 21 3 - Reactor Openings X Compliance M-easured C-alculated 98 M 99.1 M 99.9 M 63 M 100 M 96.4 C -- Resin Stripping X Compliance 92 100 100 44 99 100 96.7 Relief Valve or Manual Discharges Number Number Total Lbs. Reactor Other Released 2 1 1,826 1 0 9,817 01 850 01 65 00 0 20 95 1 1 2,453 SL 089166 VCM NESRAP SURVEY - VCM SAFETY ASSOCIATION (3-1-79 - 7-31-79) B. POLYVINYL CHLORIDE PLANT BULK 9R 42 10 2 11 6 Total Openings 215 4,732 1,507 1,798 Reactor Openings Z M-easu red Compliance C-alculated 99.0 100.0 99.9 87.3 M C C c Resin Stripping % Compliance 98.7 97 100 Relief Valve or Manual Discharges Number Number Total Lbs. Reactor Other Released 5 I 21,300 01 20 1 0 2,800 COPOLYMER Total #R Openings 34 21 Reactor Openings Z Compliance M-easured C-alculated 95.2 M Resin Stripping % Compliance 100 Relief Valve or Manual Discharges Number Number Total Lbs. Reactor Other Released 2 0 35,000 SL 089167 I VCM NESHAP SURVEY - VCK SAFETY ASSOCIATION (3-1-79 - 7-31-79) B . POLYVINYL CHLORIDE PLANT SOLUTION Total iR Openings 18 3 5 19 3 0 20 6 51 Reactor Openings Z M-easured Compliance C-alculated 100 C 100 N/A 100 C Resin Stripping Z Compliance 100 97.2 100 Relief Valve or Manual Discharges Number Number Total Lbs. Reactor Other Released 00 0 00 0 00 0 LATEX #R 65 94 Total Openings 353 1,235 Reactor Openings Z M-easured Compliance C-alculated 100 M 98.8 M Resin Stripping Z Compliance 100 97.2 Relief Valve or Manual Discharges Number Number Total Lbs. Reactor Other Released 00 0 14 160 SL 089168 VCM NESHAP SURVEY - VCM SAFETY ASSOCIATION (3-1-79 - 7-31-79) #R 24 34 42 65 75 89 94 10 2 11 6 12 5 14 3 15 6 16 6 17 9 18 3 19 3 20 6 21 3 Incinerator X Compliance 100 99-6 99.7 97.6 100 100 100 100 -- -- -- -- MONOMER RECOVERY DISCHARGE Charcoal Liquid Absorber Absorber Furnace X Compliance % Compliance Z Compliance 88 92 97.9 96 99.7 Backup -- ---- -- ---- -- ---- -- -- --- Other X Compliance 100 Gasholder -- -- -- -- Have You Received ? Notice Enforce- of ment Civil Violation Order Complaint No No --- Yes -- -- No No Yes _ Yes -- No No No No No Yes No No No -- Yes No No No No No No No No No No SL 089169 *6/1/79 to 7/31/79