Document O15bRp30nkdyQq7MaVLk3kn9j
Inspection Date: Time: Media: Statute (s)/Program(s):
Type of inspection: Access:
Permittee Name: Facility or Site Name: Facility/Site Physical Address: (City, State, Zip Code) County/Parish:
Permit and Application Number: SIC or NAICS:
EPA Region 5: Enforcement and Compliance Assurance Division
INSPECTION REPORT
June 9, 2022
Inspection Announced: No
Entry: 9:20 AM
Exit: 4:45 PM
Wastewater and Stormwater
Clean Water Act, NPDES, Industrial Stormwater, Indirect Discharger Clean Water Act, NPDES, Pretreatment, Indirect Discharger
CSI - Compliance Sampling Inspection
Granted
Vantage Oleochemicals Vantage Oleochemicals 4650 South Racine Avenue
Chicago, Illinois 60609 Cook County
No NPDES Permit
32519
Flatebo, Theodore Digitally signed by Flatebo, Theodore
Inspector Signature and Date:_________________________D_a_t_e:_2_0_2_2._0_8._0_5 _12_:_59_:_15__-0_5_'0_0'___
Approver Name and Title:
Ryan J. Bahr, Section 2 Supervisor Water Enforcement and Compliance Assurance Branch
Bahr, Ryan Digitally signed by Bahr, Ryan
Approver Signature and Date: _________________________D_a_te_:_2_0_22_._08_._0_5_1_3:_2_8:_5_5_-0_5_'0_0_' _
Page 1 of 47
Vantage Oleochemicals
June 9, 2022
Persons Participating in Inspection:
Organization/Title Name
Phone
EPA, Environmental
Engineer
EPA, Environmental
Engineer
Illinois EPA, Environmental
Engineer
MWRD, Environmental
Specialist
MWRD, Environmental
Specialist
Vantage Oleochemicals, SSHE Manager
Vantage Oleochemicals,
Site Manager
Ted Flatebo (312) 886-9402
Andi Hodaj (312) 353-4645
Jayashree Jayaraj
(847) 284-4055
Luke Toonen (773) 256-3516
Jennifer (773) 256-35115 Entwhistle
Tony Massa (773) 650-7611
Kai Slaasted (773) 650-7770
Email
flatebo.ted@epa.gov
hodaj.andi@epa.gov
jayashree.jayaraj @illinois.gov
toonenl@mwrd.org
entwhistlej@mwrd.org
tony.massa @vantagegrp.com
kai.slaasted @vantagegrp.com
Present at Present at Opening Closing Conference Conference
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
TABLE OF CONTENTS
I. Introduction......................................................................................................2 II. Facility Inspection...............................................................................................3 III. Sampling Activities and Analytical Results................................................................7 IV. Areas of Concern................................................................................................8 V. Closing Conference.............................................................................................8 VI. List of Appendices...............................................................................................9
SECTION I - INTRODUCTION
Site Entry and Inspection Objectives
U.S. Environmental Protection Agency Region 5 (EPA) inspectors Ted Flatebo and Andi Hodaj, Illinois Environmental Protection Agency (IEPA) inspector Jayashree Jayaraj, and Metropolitan Water Reclamation District of Greater Chicago (MWRD) representatives Luke Toonen and Jennifer Entwhistle arrived at Vantage Oleochemical (the "Site" or "Facility"), located at 4650 South Racine Avenue, Chicago, Illinois 60609 at 9:20
Page 2 of 47
Vantage Oleochemicals
June 9, 2022
AM on June 9, 2022 for an unannounced inspection. The two EPA inspectors, one IEPA inspector, and two MWRD staff will be collectively referred to as the inspection team.
The inspection team presented their credentials to staff at the security building who contacted Facility representative Tony Massa. After Mr. Massa arrived, the inspection team presented their credentials to him and informed him that this was an EPA inspection to determine compliance with the Clean Water Act (CWA), the National Pollutant Discharge Elimination System (NPDES) program, and National Pretreatment Standards. The inspection was conducted under the authority of the CWA NPDES program and Section 308 of the CWA. The table above identifies the attendees who participated in the inspection.
This report is based on information supplied by Facility representatives, observations made by the EPA inspectors, and records and reports maintained by the permittee, MWRD, and EPA. These include the following: direct observations made by the EPA inspectors, photographs taken by EPA inspectors, and verbal or written statements made or supplied by Facility representatives (the permittee) during or subsequent to the onsite inspection, and materials, processes, data, photographs, or documents shown, demonstrated, or submitted to the EPA inspectors by Facility representatives during or subsequent to the on-site inspection. In addition, information gathered prior to or subsequent to the inspection from a review of EPA, MWRD, and public records may be included in this report. During the opening conference, facility representatives were asked if they considered any information confidential business information (CBI). Mr. Massa stated that no information was considered CBI by the Facility.
Background Information
Prior to the inspection, EPA inspectors confirmed the following facility information:
Process wastewater generated at the Facility is covered by MWRD Discharge Authorization No. 26573-3 (Permit). The Permit places pretreatment program prohibited discharges and local limits effluent requirements on wastewater discharged to the collection system. The effective date of the Permit is April 26, 2018, and the Permit is scheduled to expire on April 25, 2023. The Facility is classified as a Significant Industrial User (SIU) by MWRD, which is an approved Control Authority under the NPDES program. The MWRD collection system that the Facility discharges to is a combined sewer, meaning it conveys both wastewater and stormwater. The Facility does not have a stormwater permit.
MWRD personnel collect compliance samples from the Facility's Outfalls twice per year. Before the inspection, EPA representatives reviewed MWRD Facility compliance sample data from January 1, 2020 to June 1, 2022. The Facility did not have any documented effluent limit exceedances during this time period. Neither the Facility nor MWRD monitors for lower/upper explosive limits (LEL/UEL) in the Facility collection system or at its Outfalls.
SECTION II - FACILITY INSPECTION
Opening Conference
After the inspection team presented their credentials to Mr. Massa, he escorted the team to Engineering, Maintenance, Purchasing, and Production building. The inspection team began their opening conference at
Page 3 of 47
Vantage Oleochemicals
June 9, 2022
approximately 9:25AM. Mr. Massa was present for the entire opening conference and Mr. Slaasted was present from approximately 9:45AM to 10:30AM.
According to Mr. Massa, the Facility produces a variety of fatty acid and glycerin products, including: vegetable Kosher glycerin, non-Kosher glycerin, oleic acid, tallow fatty acid, separated stearic acid, hydrogenated tallow fatty acid, high purity stearic acid, and distilled vegetable fatty acid. Mr. Massa reported that the North American Industrial Classification System (NAICS) code for the Facility is 32519. He also provided documentation that in 2021 the Facility produced 24,738 tons of non-Kosher glycerin, 21,498 tons of vegetable Kosher glycerin, and 202,632 tons of fatty acid products. The Facility uses a variety of non-food grade feed stocks including animal fats and vegetable oils such as soy oil, canola oil and coconut oil. The type of feed stock and its source are regularly changed based on market price and availability. Feed stocks arrive at the Facility via rail cars and truck. Final products also leave the Facility via rail cars and trucks.
Mr. Massa stated that the site where the Facility is located has historically been utilized to process animal byproducts but that since the 1950s the Facility has manufactured glycerin products. Mr. Massa also explained that the Facility underwent major upgrades in approximately 1987 but the core operations have remained the same. The Facility began operating under the name Vantage Oleochemicals in approximately 2009. The Facility operates 24 hours per day, 7 days per week. One day per year the Facility halts operations for annual maintenance activities. Mr. Massa stated the 2022 annual maintenance shutdown is scheduled for July 11th. The Facility has approximately 130 employees.
Mr. Massa explained that all of the process wastewater and the majority of the stormwater generated at the Facility is treated on site before it is discharged to the MWRD collection system. A wastewater treatment system diagram was provided to the inspection team (Appendix 2). Additional information about the wastewater treatment system is provided in the Facility Walk Through section of this inspection report.
The Facility stores hydrochloric acid on site for regenerating cation exchange columns for the water softening system, sodium hydroxide for saponification and pH adjustment within the wastewater treatment system, and phosphoric acid for pH adjustment in the wet scrubbers.
The opening conference concluded at approximately 11:00AM.
Sampling
Following the opening conference, the inspection team began to collect wastewater samples at approximately 11:15 AM. The Facility has four permitted Outfalls; 1A, 1B, 1C, and 1D. Each outfall discharges to the MWRD collection system that runs along South Racine Avenue on the Facility's east side. Outfall 1A flows east approximately 15 feet to Manhole D located in South Racine Avenue. Manhole D is located within the MWRD collection system. Per the Facility's Permit, and observations made during the inspection, the Outfalls have the following contributing flows:
Outfall 1A - Treated process effluent, treated stormwater, and untreated stormwater Outfall 2A - Sanitary wastewater, boiler blowdown, and untreated stormwater
Page 4 of 47
Vantage Oleochemicals
June 9, 2022
Outfall 3A - Sanitary wastewater and untreated stormwater Outfall 4A - Sanitary wastewater and untreated stormwater
Additional information regarding sampling is provided in Section III. Wastewater analytical results are provided in Appendix 4.
Below is a table of the observations made at each Outfall during sample collection. Gas measurements were taken using a MSA Altair 5x owned by MWRD.
Sampling Location
1A
2A 3A
4A
Manhole D
Flowing Yes Yes Yes No Yes
Observations
ISCO 4210 flow meter = 239 gallon/min, Strong chemical odor, Wastewater = 42, pH = 6, Maximum Carbon Monoxide reading = 98 ppm. Flow = ~1 gallon/min, Wastewater = 19, pH = 7. Flow = ~1 gallon/min, Wastewater = 19, pH = 7, Maximum carbon monoxide measurement = 77 ppm, Maximum oxygen measurement = 21.3%. Not flowing, no measurements taken with gas meter. Flow = ~239 gallon/min, Strong chemical odor, Wastewater = 42, pH = 6, Maximum carbon monoxide measurement = 302 ppm, Maximum hydrogen sulfide measurement = 5 ppm.
Facility Walk Through
The inspection team concluded sampling at approximately 1:00 PM. The team took a short lunch break and began the Facility walk through at approximately 1:30 PM. Mr. Massa walked the inspection team through the Facility process lines. The general process flow involves the raw material passing through the splitters, hydrogenation, and then vacuum distillation. At each stage of the process the concentration of glycerin is increased. A Facility process flow diagram is provided in Appendix 3.
After material is delivered to the Facility it is pumped to the raw material tank farm to be stored. Tallow raw material is sometimes passed through a filter to remove large impurities such as hair and bone. Not all tallow material passes through the filter before processing. The material is then sent to the splitting columns to undergo hydrolysis.
Before hydrolysis, tallow fatty acids are separated into crude stearic acid and crude oleic acid with a filter press after chilling the mixture to around 50. The Facility uses a continuous hydrogenation process to saturate the fatty acids. This process adds gaseous hydrogen to the material and utilizes a nickel catalyst. According to Mr. Massa, the Facility historically utilized a batch hydrogenation process but converted to a continuous hydrogenation process in approximately 2002. Similarly, the Facility historically used a wet separation process but in approximately 2015 converted to a dry separation process.
As part of the Kosher glycerin distillation process, salt is produced. The Facility considers the salt a waste product and it is disposed in a landfill as a non-hazardous waste. Mr. Massa estimated that 2-3 million pounds
Page 5 of 47
Vantage Oleochemicals
June 9, 2022
of salt are generated at the Facility per year. Additionally, fatty acid residuals are generated during the glycerin distillation process. The residuals from this process are a solid material that is also sent to a landfill for disposal as a non-hazardous waste.
Mr. Massa explained that all the pipes within the Facility have a steam jacket or a different heating element around them to ensure the contents of the pipe are heated and flowing properly. The inspection team observed a steam hose placed in a drain within the Facility. Mr. Massa explained that when pipes get clogged, Facility personnel can inject steam to heat the blockage and restore flow. Additionally, there are stream traps throughout the Facility that collect steam condensate and discharge it to the Facility's collection system for treatment.
Mr. Massa also explained that between uses, pipes that connect tanks must be cleared to prevent cross contamination of different products. The pipes are blown out onto the ground within the secondary containment areas and allowed to flow to drains that direct the waste to the main catch basin for treatment. Similarly, when a sample is collected from the port attached to the bottom of tanks, operators will allow the port to flow onto the ground for a few seconds before the sample is collected.
The Facility has multiple tank farms to store material. The air in the headspace of these tanks is collected and sent to a wet scrubber for odor control. The Facility has four wet scrubbers, the wastewater generated by the scrubbers is sent to the main catch basin for treatment.
Wastewater is generated from a variety of sources, including: the steam condensation, pipe blowdown, sampling blowdown, and wet scrubbers described above as well as boiler blowdown, secondary containment stormwater, wash water, and cooling tower blowdown. All wastewater generated at the Facility flows to the main catch basin for treatment. Most of the stormwater from the Facility also flows to the main catch basin for treatment. There are some storm inlets located within the Facility that bypass treatment and flow directly to the MWRD collection system.
Water flows from the main catch basin to Tank 163. From Tank 163 wastewater flows via gravity to the hydroskimmer. According to Mr. Massa, the hydroskimmer is approximately 15-20 feet deep and allows fats to separate from the wastewater. A fat recovery pump was installed within the hydroskimmer in early 2021 to allow for easier recovery of fat from the system. Following the hydroskimmer, the water is treated by a coagulant (aluminum chloride hydroxide), then 50% sodium hydroxide for pH adjustment, then a polymer (Kurifloc 4224) before it reaches the dissolved air floatation (DAF) system. The DAF system generates sludge that is stored in two 5,000 gallon tanks inside the DAF building. These tanks are emptied twice per week and the contents are hauled off site for solidification and stabilization or for biodigestion. Following the DAF system, the treated effluent is either recycled back to the hydroskimmer to maintain its water level or it is discharged through outfall 1A. A wastewater treatment diagram is provided in Appendix 2.
Outfall 1A has a ISCO 4210 ultrasonic flow meter to measure effluent flows. This Outfall discharges an average of approximately 300,000 gallons per day during dry weather. The flow meter is calibrated annually by a contractor. Per the Facility's permit, compliance samples must be collected and analyzed twice annually. The sampling and analysis are conducted by a contractor on the Facility's behalf.
Page 6 of 47
Vantage Oleochemicals
June 9, 2022
Mr. Massa stated the DAF system was installed in the early 2000's to replace the use of the aeration pond located on site. The pond was observed by inspectors to still contain water, but Mr. Massa stated that the pond is completely fenced in and that it is no longer utilized in any way by the company. Mr. Massa also explained that the pond's only source of influent is stormwater and there are no outlets for the water.
Mr. Massa explained that on Saturday, June 4, 2022 that Facility encountered two abnormal situations:
The first was pH effluent violation from the dissolved air floatation (DAF) system. The Facility's permit authorizes wastewater to be discharged with a pH between 5.0 - 10.0. On this day, wastewater was discharged with a pH of 4.26. Upon discovering the violation, a Facility representative called MWRD to inform them of the situation. Mr. Massa explained that the recirculating pump for the sodium hydroxide used in the DAF system for pH adjustment was broken and the problem was resolved in approximately 75 minutes.
The second situation was the leak in the wall of a hydrochloric acid tank within the Facility which was discovered on June 4, 2022. Mr. Massa explained that the leak was captured within the secondary containment and a contractor was hired to neutralize the acid. During the inspection, the team observed a contractor use a vac truck to load the neutralized waste and dispose of it in the main catch basin that leads to the wastewater treatment system.
SECTION III - SAMPLING AND ANALYTICAL RESULTS
Wastewater samples were collected from five locations during the inspection. Samples were analyzed for volatile organic compounds (VOCs) by the U.S EPA Region 5 Analytical Service Branch. Mr. Slaasted accompanied the inspection team while they sampled within the Facility, he did not accompany them to Manhole D. The inspection team offered split samples for each sample collected. Mr. Slaasted accepted split samples for sample location 1A but declined split samples for all other sample locations. Split samples were collected in the same manner as the samples analyzed by EPA.
Sample were collected from the following locations:
1A: 2A: 3A: DAF: Manhole D:
MWRD Discharge Authorization Sample Location 1A MWRD Discharge Authorization Sample Location 2A MWRD Discharge Authorization Sample Location 3A Effluent from the dissolved air floatation (DAF) treatment system First manhole in the MWRD collection system to receive water from sample location 1A
Below is a summary of analytes that were detected in concentrations above 100 ug/L. The full sampling analytical data report is provided in Appendix 4.
Analyte
Acrolein Acetone 2-Butanone 2-Hexanone
Manhole D (ug/L)
676 2380
665 165
1A (ug/L)
578 2350
611 178
DAF (ug/L)
494 2330
610 170
2A (ug/L)
2.02 28.5 2.61
ND
3A (ug/L)
Non-Detect 31.5 8.14 3.57
Page 7 of 47
Vantage Oleochemicals
June 9, 2022
SECTION IV - AREAS OF CONCERN
The presentation of areas of concern does not constitute a formal compliance determination.
Unique Identifying No. TF-OB-001
Record
Spent nickel catalysis is stored in large sacks outdoors. The sacks are not sealed and have potential expose to stormwater.
TF-OB-002 There is a large crack in the south wall of the hydroskimmer.
TF-OB-003 Water was observed bubbling out of a manhole immediately east of the DAF building.
TF-OB-004 TF-OB-005
There is a large buildup of solidified stearic acid on the ground in the stearic acid loading area.
One of the DAF effluent pH probes is due for calibration.
TF-OB-006 TF-OB-007
One June 3, 2022, there was a pH effluent violation caused by the failure of the sodium hydroxide recirculating pump.
On June 3, 2022, there was a leak of hydrochloric acid due to storage container failure.
TF-OB-008 A steam hose was being used to break up a suspected solidified fat blockage in a drain.
TF-OB-009
There were bubbles coming up through the water of the hydroskimmer. The source of these bubbles was not immediately clear.
SECTION V - CLOSING CONFERENCE
Closing Conference
The inspection team held a closing conference with Facility personnel beginning at approximately 4:15PM. During the closing conference, inspectors discussed the observations and Areas of Concern identified during the inspection. Observations and Areas of Concern have not yet been evaluated for a formal compliance determination. The inspection team departed the Facility at approximately 4:45 PM.
Page 8 of 47
Vantage Oleochemicals
SECTION VI - LIST OF APPENDICES Appendix 1 - Photo Log Appendix 2 - Wastewater Treatment System Diagram Appendix 3 - Process Flow Diagram Appendix 4 - Sampling Analytical Data Report
June 9, 2022
Page 9 of 47
Vantage Oleochemicals
Appendix 1
Vantage Oleochemicals EPA Inspection: June 9, 2022 All photos taken by Andi Hodaj, Environmental Engineer, U.S. EPA
Camera: Ricoh WG-4
June 9, 2022
1: RIMG2742 Description: Inside MWRD Sampling Point 1A. Location: Along facility east fence line, east of glycerin distillation tank farm. Camera Direction: Down. Date/Time: June 9, 2022, 11:20
Page 10 of 47
Vantage Oleochemicals
June 9, 2022
2: RIMG2743 Description: Overview of MWRD Sampling Point 1A. Location: Along facility east fence line, east of glycerin distillation tank farm. Camera Direction: East Date/Time: June 9, 2022, 11:20
3: RIMG2744 Description: Wastewater samples collected from MWRD Sampling Point 1A. Location: Along facility east fence line, east of glycerin distillation tank farm. Camera Direction: East Date/Time: June 9, 2022, 11:20
Page 11 of 47
Vantage Oleochemicals
June 9, 2022
4: RIMG2745 Description: Overview of MWRD Sample Point 2A. Location: Along facility east fence line, east of locker room. Camera Direction: Northeast Date/Time: June 9, 2022, 11:44
Page 12 of 47
Vantage Oleochemicals
June 9, 2022
5: RIMG2746 Description: Inside of MWRD Sample Point 2A. Location: Along facility east fence line, east of locker room. Camera Direction: Down Date/Time: June 9, 2022, 11:45
Page 13 of 47
Vantage Oleochemicals
June 9, 2022
6: RIMG2747 Description: Wastewater samples collected from MWRD Sample Point 2A. Location: Along facility east fence line, east of locker room. Camera Direction: North Date/Time: June 9, 2022, 11:56
7: RIMG2748 Description: Inside Manhole D Location: Manhole in South Racine Aveune that recieves flow from Sample Point 1A. Approximately 15 feet east from Sample Point 1A. Photo obscured by steam exiting manhole. Camera Direction: Down Date/Time: June 9, 2022, 12:09
Page 14 of 47
Vantage Oleochemicals
June 9, 2022
8: RIMG2749 Description: Overview photo of Manhole D. Location: Manhole in South Racine Aveune approximately 15 feet east from Sample Point 1A. Camera Direction: Down Date/Time: June 9, 2022, 12:09
Page 15 of 47
Vantage Oleochemicals
June 9, 2022
9: RIMG2750 Description: Wastewater samples collected from Manhole D. Location: Manhole in South Racine Aveune approximately 15 feet east from Sample Point 1A. Camera Direction: East Date/Time: June 9, 2022, 12:14
10: RIMG2751 Description: Inside Manhole D. Photo obscured by steam exiting manhole. Location: Manhole in South Racine Aveune approximately 15 feet east from Sample Point 1A. Camera Direction: Down Date/Time: June 9, 2022, 12:14
Page 16 of 47
Vantage Oleochemicals
June 9, 2022
11: RIMG2752 Description: Summary of measurements taken my MWRD gas meter. Location: Manhole D. Camera Direction: Down. Date/Time: June 9, 2022, 12:16
12: RIMG2753 Description: Overview of MWRD Sample Point 3A. Location: Along facility east fence line, southeast of security building. Camera Direction: East Date/Time: June 9, 2022, 12:20
Page 17 of 47
Vantage Oleochemicals
June 9, 2022
13: RIMG2754 Description: Inside MWRD Sample Point 3A. Location: Along facility east fence line, southeast of security building. Camera Direction: Down Date/Time: June 9, 2022, 12:22
14: RIMG2755 Description: Inside MWRD Sample Point 3A. Location: Along facility east fence line, southeast of security building. Camera Direction: Down Date/Time: June 9, 2022, 12:22
Page 18 of 47
Vantage Oleochemicals
June 9, 2022
15: RIMG2756 Description: Inside MWRD Sample Point 3A. Location: Along facility east fence line, southeast of security building. Camera Direction: Down Date/Time: June 9, 2022, 12:24
16: RIMG2757 Description: Wastewater samples collected from MWRD Sample Point 3A. Location: Along facility east fence line, southeast of security building. Camera Direction: East Date/Time: June 9, 2022, 12:33
Page 19 of 47
Vantage Oleochemicals
June 9, 2022
17: RIMG2758 Description: Overview of MWRD Sample Point 4A. Location: South end of employee parking lot, north of administration building. Camera Direction: West Date/Time: June 9, 2022, 12:38
18: RIMG2759 Description: Overview of effluent treatment system building. Location: Immedialtey northeast of DAF building. Camera Direction: Northwest Date/Time: June 9, 2022, 12:50
Page 20 of 47
Vantage Oleochemicals
June 9, 2022
19: RIMG2760 Description: Overview of DAF building. Location: Immediately south of hydroskimmer. Camera Direction: West Date/Time: June 9, 2022, 12:51
20: RIMG2761 Description: Sodium Hydroxide (50%) storage tank, used for effluent pH neutralization. Location: South of effluent treatment building. Camera Direction: North Date/Time: June 9, 2022, 12:51
Page 21 of 47
Vantage Oleochemicals
June 9, 2022
21: RIMG2762 Description: Overview of DAF treatment system. Effluent flowing out of the system on the right side of the photo. Location: Inside DAF bulding. Date/Time: June 9, 2022, 12:52
22: RIMG2763 Description: Effluent samples collected from DAF treatment system effluent. Location: Inside DAF building. Date/Time: June 9, 2022, 12:57
Page 22 of 47
Vantage Oleochemicals
June 9, 2022
23: RIMG2764 Description: Water pooling on top of manhole. Source of water was not immediately clear. Location: Between DAF building and effluent treatment building. Camera Direction: West Date/Time: June 9, 2022, 12:58
24: RIMG2765 Description: Combined sewer inlet downstream of wastewater treatment system. Location: South of glycerin loading/unloading station. Camera Direction: North Date/Time: June 9, 2022, 13:37
Page 23 of 47
Vantage Oleochemicals
June 9, 2022
25: RIMG2766 Description: Railcard unloading bulding. Each of the two tracks can accommodate 3 railcars at once. Location: Camera Direction: North Date/Time: June 9, 2022, 13:39
26: RIMG2767 Description: Raw material tank farm. Location: North of railcar unloading building. Camera Direction: North Date/Time: June 9, 2022, 13:41
Page 24 of 47
Vantage Oleochemicals
June 9, 2022
27: RIMG2768 Description: Steam trap - collects non-contact steam condensation and discharges to drain. Water is treated on site before it is discharged as effluent. Location: Adjacent to raw material tank farm. Camera Direction: North Date/Time: June 9, 2022, 13:42
28: RIMG2769 Description: Tallow storage tank. Note faded NFPA panel. Location: Raw material tank farm. Camera Direction: Norht Date/Time: June 9, 2022, 13:44
Page 25 of 47
Vantage Oleochemicals
June 9, 2022
29: RIMG2770 Description: Collection of oil and grease inside secondary containment. Location: Raw material tank farm. Camera Direction: East Date/Time: June 9, 2022, 13:44
30: RIMG2771 Description: Collection of oil and grease inside secondary containment. Location: Raw material tank farm. Camera Direction: East Date/Time: June 9, 2022, 13:44
Page 26 of 47
Vantage Oleochemicals
June 9, 2022
31: RIMG2772 Description: Overview of splitting columns. Location: Fatty acid splitting colums Camera Direction: East Date/Time: June 9, 2022, 13:45
32: RIMG2773 Description: Fat stock filter and dumpster for separated debris. Location: West side of raw material tank farm. Camera Direction: North Date/Time: June 9, 2022, 13:54
Page 27 of 47
Vantage Oleochemicals
June 9, 2022
33: RIMG2774 Description: Debris from fat stock filter. Location: West side of raw material tank farm. Camera Direction: North Date/Time: June 9, 2022, 13:54
34: RIMG2775 Description: Standing water unable to flow into drain. Black hose is injecting steam into collection system to dislodge a potential blockage. Location: West side of raw material tank farm. Camera Direction: North Date/Time: June 9, 2022, 13:58
Page 28 of 47
Vantage Oleochemicals
June 9, 2022
35: RIMG2776 Description: Overview of hydrogenation reactor. Location: South of hydrogen and nitrogen storage tank area. Camera Direction: West Date/Time: June 9, 2022, 14:01
36: RIMG2777 Description: Bags of spent nickel catalyst from the hydrogenation process. Location: West of dissolved air floatation (DAF) building. Camera Direction: East Date/Time: June 9, 2022, 14:03
Page 29 of 47
Vantage Oleochemicals
June 9, 2022
37: RIMG2778 Description: Wet scrubber blowdown pipe. Location: South of raw material tank farm. Camera Direction: Southwest Date/Time: June 9, 2022, 14:11
Page 30 of 47
Vantage Oleochemicals
June 9, 2022
38: RIMG2779 Description: Vacuum truck unloading dilluted waste into main catch basin from hydrochloric acid spill that occurred on site. Location: Main catch basin Camera Direction: North Date/Time: June 9, 2022, 14:15
Page 31 of 47
Vantage Oleochemicals
June 9, 2022
39: RIMG2780 Description: Storage tank sample valve located in red circle. Note excess waste during sample collection is allowed to flow onto the ground. Location: Distillation tank farm. Camera Direction: East Date/Time: June 9, 2022, 14:30
40: RIMG2781 Description: 55-gallon drums and pallet totes stored outdoors with no secondary containment. Location: Waste oil and miscellaneous drum storage area. Adjacent to tank 185. Camera Direction: South Date/Time: June 9, 2022, 14:31
Page 32 of 47
Vantage Oleochemicals
June 9, 2022
41: RIMG2782 Description: Build up of solidified stearic acid. Location: Stearic acid loading area. Camera Direction: Southwest Date/Time: June 9, 2022, 14:33
42: RIMG2783 Description: Standing water with mist falling down from wet scrubber exhaust. Green dumpsters in background contain large bags of spent nickel catalyst. Location: East of glycerin distillation building. Camera Direction: East Date/Time: June 9, 2022, 14:54
Page 33 of 47
Vantage Oleochemicals
June 9, 2022
43: RIMG2784 Description: Overview of glycerin distillation wet scrubber. Location: North of glycerin distillation #1. Camera Direction: South Date/Time: June 9, 2022, 14:55
44: RIMG2785 Description: Overview of main catch basin. Location: Main catch basin. Camera Direction: East Date/Time: June 9, 2022, 15:00
Page 34 of 47
Vantage Oleochemicals
June 9, 2022
45: RIMG2786 Description: Overview of tank 163, which recieves flow from main catch basin. Note broken NFPA panel. Location: Raw material tank farm. Camera Direction: Northeast Date/Time: June 9, 2022, 15:04
46: RIMG2787 Description: Blowdown from Conti scrubber. Location: Conti hardening area. Camera Direction: North Date/Time: June 9, 2022, 15:05
Page 35 of 47
Vantage Oleochemicals
June 9, 2022
47: RIMG2788 Description: Influent into hydroskimmer. Location: Hydroskimmer. Camera Direction: North Date/Time: June 9, 2022, 15:09
48: RIMG2789 Description: Overview of hydroskimmer. Location: Hydroskimmer. Camera Direction: Northeast Date/Time: June 9, 2022, 15:10
Page 36 of 47
Vantage Oleochemicals
June 9, 2022
49: RIMG2791 Description: Collection of solids in the hydroskimmer. Location: Hydroskimmer. Camera Direction: North Date/Time: June 9, 2022, 15:17
50: RIMG2793 Description: Collection of solids in the hydroskimmer. Location: Hydroskimmer. Camera Direction: North Date/Time: June 9, 2022, 15:17
Page 37 of 47
Vantage Oleochemicals
June 9, 2022
51: RIMG2794 Description: Crack in the south wall of the hydroskimmer. Location: South wall of the hydroskimmer. Camera Direction: North Date/Time: June 9, 2022, 15:20
52: RIMG2795 Description: Water bubbling out of manhole. Location: East of DAF building. Camera Direction: Down Date/Time: June 9, 2022, 15:21
Page 38 of 47
Vantage Oleochemicals
June 9, 2022
53: RIMG2797 Description: Water bubbling out of manhole. Location: East of DAF building. Camera Direction: Down Date/Time: June 9, 2022, 15:21
54: RIMG2798 Description: Water bubbling out of manhole. Note presense of bubbles. Location: East of DAF building. Camera Direction: Down Date/Time: June 9, 2022, 15:21
Page 39 of 47
Vantage Oleochemicals
June 9, 2022
55: RIMG2799 Description: Overview of 50% sodium hydroxide storage tank used for pH neutralization. Location: Northeast of DAF building. Camera Direction: West Date/Time: June 9, 2022, 15:25
56: RIMG2800 Description: Parallel pH probes for DAF influent. Location: Inside DAF building. Camera Direction: North Date/Time: June 9, 2022, 15:30
Page 40 of 47
Vantage Oleochemicals
June 9, 2022
57: RIMG2802 Description: Overview of DAF treatment system. Location: Inside DAF building. Camera Direction: West Date/Time: June 9, 2022, 15:38
58: RIMG2803 Description: Storage tanks for sludge generated during DAF treatment. Location: Inside the DAF building. Camera Direction: South Date/Time: June 9, 2022, 15:38
Page 41 of 47
Vantage Oleochemicals
June 9, 2022
59: RIMG2804 Description: Effluent from the DAF treatment system overflows from a weir into a grate below. Location: Inside the DAF building. Camera Direction: Down Date/Time: June 9, 2022, 15:39
Page 42 of 47
Vantage Oleochemicals
June 9, 2022
Appendix 2 Wastewater Treatment System Diagram
Page 43 of 47
Vantage Oleochemicals
June 9, 2022
Page 44 of 47
Vantage Oleochemicals
June 9, 2022
Appendix 3 Process Flow Diagram
Page 45 of 47
Vantage Oleochemicals
June 9, 2022
Page 46 of 47
Vantage Oleochemicals
June 9, 2022
Appendix 4 Sampling Analytical Data Report
Page 47 of 47
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY US EPA Region 5 LSASD Analytical Services Branch 536 SOUTH CLARK STREET CHICAGO, ILLINOIS 60605
Date:
7/27/2022
Title: To:
From:
ASB Data Report for Vantage Olechemical
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago, IL 60604
Kristen Leckrone, Chemist leckrone.kristen@epa.gov US EPA Region 5 LSASD Analytical Services Branch
The results reported in this document apply to the samples as received and relate only to the items tested. The data transmitted under this cover memo successfully passed the data review process and applicable Analytical Services Branch (ASB) laboratory Standard Operating Procedures. In accordance with the EPA QA/G-8 Guidance on Environmental Data Verification and Data Validation, ASB performs data verification on all the data generated internally. ASB does not perform data validation or quality assessment procedures.
This report was reviewed and the information provided herein accurately represents the analysis performed.
Please contact the analyst with any technical report issues, Amanda Wroble at (312)-353-0375 for sample project concerns, and Robert Snyder at (312)-353-9083 with data transmittal questions. Thank you.
Attached are Results for: Vantage Olechemical
Analyses included in this report: VOA - 8260
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 1 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Accredited Analyses included in this Report
Reported: Jul-27-22 16:36
Method: Analysis: Analyte
EPA 8260C in Water VOA - 8260
Dichlorodifluoromethane
Chloromethane
Vinyl chloride
Bromomethane
Chloroethane
Trichlorofluoromethane
Acrolein
1,1-Dichloroethene
Acetone
Carbon disulfide
Methylene chloride
Acrylonitrile
trans-1,2-Dichloroethene
Methyl tert-butyl ether
1,1-Dichloroethane
2,2-Dichloropropane
cis-1,2-Dichloroethene
Certifications ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 2 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Accredited Analyses included in this Report
Reported: Jul-27-22 16:36
Method: Analysis: Analyte
EPA 8260C in Water VOA - 8260
2-Butanone
Bromochloromethane
Chloroform
1,1,1-Trichloroethane
Carbon tetrachloride
1,1-Dichloropropene
Benzene
1,2-Dichloroethane
Trichloroethene
1,2-Dichloropropane
Dibromomethane
Bromodichloromethane
cis-1,3-Dichloropropene
4-Methyl-2-pentanone
Toluene
trans-1,3-Dichloropropene
1,1,2-Trichloroethane
Tetrachloroethene
1,3-Dichloropropane
Certifications ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 3 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Accredited Analyses included in this Report
Reported: Jul-27-22 16:36
Method: Analysis: Analyte
EPA 8260C in Water VOA - 8260
2-Hexanone
Dibromochloromethane
1,2-Dibromoethane (EDB)
Chlorobenzene
1,1,1,2-Tetrachloroethane
Ethylbenzene
m+p-Xylene
o-Xylene
Styrene
Bromoform
Isopropylbenzene
Bromobenzene
1,2,3-Trichloropropane
n-Propylbenzene
2-Chlorotoluene
1,3,5-Trimethylbenzene
4-Chlorotoluene
1,1,2,2-Tetrachloroethane
tert-Butylbenzene
Certifications ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 4 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Accredited Analyses included in this Report
Reported: Jul-27-22 16:36
Method: Analysis: Analyte
EPA 8260C in Water VOA - 8260
1,2,4-Trimethylbenzene
sec-Butylbenzene
1,3-Dichlorobenzene
p-Isopropyltoluene
1,4-Dichlorobenzene
1,2-Dichlorobenzene
n-Butylbenzene
1,2-Dibromo-3-chloropropane
1,2,4-Trichlorobenzene
Hexachlorobutadiene
Naphthalene
1,2,3-Trichlorobenzene
Certifications ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017 ISO/IEC 17025:2017
Analytes not listed above are not accredited by ANAB.
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 5 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
ANALYSIS CASE NARRATIVE
General Information. Six samples were received by the Analytical Services Branch (ASB) on June 9, 2022 as work order (WO) 2206006, and were analyzed June 1st and 2nd for volatile organic compounds (VOCs) in batches B22F054 (screening only, not reported) and B22F058. All samples were refrigerated until analysis and met preservation (acidification) and hold time (14 days) requirements. The designated analyst for these samples, Kristen Leckrone, can be reached at (312) 353-9058. Analyst-in-training Emerita Quiamjot assisted with preparation of calibration standards and programming the initial instrument calibration sequence. Processing of all calibration files, completion of the associated processing method, and preparation and analysis of all continuing calibrations, batch quality control samples and client samples were performed by the designated analyst.
Sample Analysis and Results. Sample preparation and analysis were performed on the EST Purge and Trap Autosampler and Concentrator System and GC/MS#11 instrument via ASB standard operating procedure (SOP) MS023, VOA in Water (Based on EPA Method SW-846:8260C), Version 8 as modified by Pen & Ink (P&I) 27389. Data review was performed according to the guidelines in ASB SOP MS037 v.5 as modified by P&Is 21549 and 28831.
The data reported herein meets the requirements referenced in the referenced SOPs, except as discussed in the Quality Control section below. No additional client specifications different than or beyond those in the referenced SOPs were provided in the analytical request form "Vantage Olechemical, 4650 S. Racine, Chicago, IL, request date 6/1/22". The standard MS023 analyte list is reported. Although not requested, the by-request compounds acrolein, acrylonitrile, and methyl tert-butyl ether are reported as a courtesy, because acrolein was observed at significant levels in several samples. In addition to the standard list and by-request analytes, many peaks were observed in the chromatogram for samples 2206006-01, 2206006-04, and 2206006-06, which do not coincide with any MS023 analytes. Some of these peaks were much larger than any of the listed MS023 analytes. Tentatively identified compounds (TICs) are discussed in the TIC section of the QC narrative below.
Quality Control. All quality control (QC) requirements were within ASB limits for the analytes or did not result in qualification of the data except as described below.
Initial calibration. The lowest calibration point, 1 ug/L, was dropped for acrolein and acrylonitrile, which could only be calibrated from 2 ug/L to 100 ug/L, rather than from 1 - 100 ug/L for most other analytes (2 - 200 ug/L for 2-hexanone, see MRL section below). The shortened calibration for acrolein and acrylonitrile met initial calibration requirements for number of calibration levels and for linearity. Although calibrated, 2-chloroethyl vinyl ether is not reported because it is unstable in acidic solution. Analysis for this analyte requires collected of separate, unacidified samples.
Calibration was verified via a 2nd-source initial calibration verification (ICV) standard. The ICV failed low for dichlorodifluoromethane and chloroethane. These analytes are qualified L, (ICV), low bias observed in the ICV, for all field and QC samples, including both detected and undetected results. The analytes acrolein, acrylonitrile, methyl tert-butyl ether, 2-butanone, 4-methyl-2-pentanone, and 2-hexanone are absent from the ICV mix, so calibration for these analytes is not subject to second-source verification.
The accuracy of the low-level calibration was evaluated by reprocessing calibration points through the calibration equations at calibration level 2, which represents the method reporting limit (RL, 2 ug/ L for most compounds, 4 ug/L for 2-hexanone), and at calibration level 1 (half the reporting limit, 1 ug/ L most analytes, 2 ug/L for hexanone). Accuracy within
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 6 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
the 50-150% limit was confirmed for all analytes down to calibration level 1, except for acrolein and acrylonitrile, which were recovered acceptably at the reporting limit,, but are not evaluated at 1 ug/ L due to their shortened calibration. No results, including blanks, are reported below 2 ug/ L for either of these analytes.
Blanks. For most analytes, blanks were evaluated down to the method detection limit (MDL). No analytes were detected down to this level in any method blanks. For acrolein and acrylonitrile, blanks could not be evaluated below the MRL due to the shortened calibration.. For these two analytes, no blanks were detected down to the 2 ug/ L reporting limit. All sample results for these analytes met blank criteria that detected sample results exceed 5x the highest measured blank. No blank qualifiers were required for any analytes.
Blank spike/blank spike duplicate (-BS/BSD). Acrolein was also recovered below acceptance limits in batch B22F054, an unreported screening batch for work order 2206006, but multiple samples in the screening batch showed significant hits for this compound. As an on-the-spot corrective action, a new ampoule of acrolein was opened. (The ampoule also contained acrylonitrile, since both analytes are present together as a commercial mix, but performance in the prior solution was still in control). New spiking solutions and -BS/BSD control samples were prepared, including with all analytes (B22F054-BS1, -BSD1, and -BS3), and with only acrolein and acrylonitrile (B22F054-BS2, -BSD2, and -BS4), as simplified solutions prepared with minimal handling. Acceptable calibration of acrolein was established from the latter solutions (-BS2, -BSD2 and -BS4), so no qualification of acrolein was required for samples in batch B22F058.
Dichlorodifluoromethane, chloromethane and vinyl chloride were recovered low in B22F058-BS1, -BSD1, and -BS3, and bromomethane was recovered low in B22F058-BSD1 and -BS3. These analytes are qualified L, LCS for all samples in the batch, including both detected and nondetected results. Chloroethane was recovered low in B22F058-BS3. Results are already qualified L, (ICV). An (LCS) descriptive qualifier is added to affected samples 2206006-01RE4 and -06RE5, which are the only injections bracketed by -BS3. Carbon disulfide was recovered above limits in B22F058-BS1 and -BSD1, but there is no impact to data because in was undetected in samples bracketed by these standards.
Matrix Spike and Duplicate (MS and MSD). No sample or QC results, including the MS/MSD, are reported from batch B22F052, a 50x screening batch performed to identify the correct dilutions at which to analyze for each analyte. Although only one MS/MSD pair is required per batch, in batch B22F058, two MS/MSD pairs were performed due to the wide range of concentrations of analytes in the samples. One MS/MSD pair was prepared for the 20x bench dilution, and a second pair for the undiluted (1x) source. Each analyte is reported in the source and the MS/MSD of matching dilution. All analytes passed in the MS/MSDs for which they were on scale and reported, and no matrix qualifiers were required.
Tentatively Identified Compounds (TICs). For samples 2206016-01, 2206016-04, and 2206016-06, , the total ion chromatograms were dominated by peaks that did not correspond to supported analytes in MS023, including many which were significantly larger than the supported compounds, surrogates and internal standards. Unidentified peaks in the total ion chromatogram were searched against the National Institute of Standards & Technology (NIST) spectral library, and the highest library matches were evaluated against TIC qualitative acceptance criteria in MS 023. The eleven most significant TICs were tentatively identified as acetaldehyde, 2-heptanone, 2-octanone, 1-octanol, 2-nonanone, 1-heptanol, 1-hexanol, 1-butanol, 2-decanone, 1-nonanol, and 2-octanol, in order of decreasing peak area. This is consistent with observations that the highest concentrations of MS023-supported analytes were also aldehydes (acrolein, 286 ug/L) and ketones (acetone, 2-butanone, 2-hexanone measured at 3110, 804, and 176 ug/L, respectively). Alcohols are not generally analyzed by VOA-8260 purge and trap methods, and no alcohols are included in the standard MS023 analyte list, so there are no listed alcohols against which to compare the magnitudes of the unlisted ones. Unsupported analytes cannot be reliably quantitated from the total ion chromatogram, however, the peak area of the eleven TICs named above ranged from 25 to 5 times the average area of the 50 ug/L internal standards. Based on their peak areas relative to those of the
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 7 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
known 50 ug/L internal standards, a crude order-of-magnitude estimate is that these eleven compounds could be present in concentrations of hundreds to thousands of ug/L. If alcohols, aldehydes, and/or ketones are important for the site these samples represent, it may be of value to identify laboratories and methods that support analysis of these compound classes.
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 8 of 43
30192345156718974355871839517195743591854
!"#$#%%& '(")&*+,, -.%/0123456, 7"8/0123554291
?@A@<0
BBCDCCD :;07351;;<19839;74237=>491
43187MJNOOBCBBPJCBJQR
3718J ?9874<323=351E?07351 45I78JF91897@77639
45I78R91974J 179@ S49==9<923= 45I78KL674J G1517H
7T548U5J [.]'^]"_ V"%#W'X'Y'.&VZ [\%)'.
W"%W%/ \%(%'X%]ac/ +))%]*.ac/
`!424221/,,0b]"cd[d3 +'Y[..'7!#%Y \e%#.c]%#
66V%Y`"($Y.a!%X"#] '(")&*+,,b W"%\%(%'X%]/ `.4,942216/ W"%+))%]*./ `.41,42211/16
-.%/01234bb 7"8/01235542,,1
"fg!%")Yh!"e%!Y %"!Y*."( \%(%'X%].'(% -"g%#i#$*.(!]%]
j7= ?54S@4M74566718=J j7= gch\%!)k#f22,,1l j7= j7=
!%#0Y3'.k#f"'./ W%k"! !%#419l,,
;96T7m<J BBCDCCDoCn ;96T7K967J n ;96T7566718=J
19 =3= [452,
;96T7MJ tL1oCuoBBnnJnN R9843pJ ?9874
vwxyz{|}~xy~xx
;96T7598351O566718=J R?<74638n
q5M8367rM9=s
0pT347= 566718=
1b
`.4242211/16
;96T7m<J BBCDCCDoCB ;96T7K967J B ;96T7566718=J
19 =3= [452,
;96T7MJ tL1oCuoBBnnJC R9843pJ ?9874 ;96T7598351O566718=J R?<74638B
q5M8367rM9=s
0pT347= 566718=
1b
`.4242211/,
;96T7m<J BBCDCCDoC ;96T7K967J U43T>91S ;96T7566718=J
19 =3= [452,
;96T7MJ tL1oCuoBBnnJ R9843pJ ?9874 ;96T7598351O566718=J U43T>91S
q5M8367rM9=s
0pT347= 566718=
1b
`.4242211/
Page9of43
Page 10 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
1A (2206006-01RE3)
Analyte Acrolein Acetone 2-Butanone 2-Hexanone
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
1A (2206006-01RE4)
Analyte Dichlorodifluoromethane
Chloromethane Vinyl chloride Bromomethane Chloroethane
Trichlorofluoromethane 1,1-Dichloroethene Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water
Sampled: Jun-09-22 11:17
Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
578
40.0
ug/L
20
B22F058
2350
200
"
"
"
611
200
"
"
"
178
80.0
"
"
"
Result 10.4 10.7 9.56 10.3
%REC 104% 106% 95.6% 103%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared Jun-15-22
" " "
Prepared " " " "
Analyzed Jun-16-22
" " "
Analyzed " " " "
Matrix: Water
Sampled: Jun-09-22 11:17
Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
U
(ICV), (LCS),
L
6.83
(LCS), L
2.00
ug/L
2.00
"
1
B22F058
"
"
U
(LCS), L
2.00
"
"
"
U
(LCS), L
2.00
"
"
"
U
(ICV), (LCS),
L
U
2.00
"
"
"
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
12.1
2.00
"
"
"
Prepared Jun-15-22
" " " "
" " " " " " " " " " " " " " " "
Analyzed Jun-17-22
" " " "
" " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 11 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
1A (2206006-01RE4)
Analyte
1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water
Sampled: Jun-09-22 11:17
Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
U
2.00
ug/L
1
B22F058
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
7.91
4.00
"
"
"
3.39
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
4.00
"
"
"
U
2.00
"
"
"
6.84
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
Prepared
Jun-15-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Analyzed
Jun-17-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 12 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
1A (2206006-01RE4)
Analyte 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
2A (2206006-02RE1)
Analyte Dichlorodifluoromethane
Chloromethane Vinyl chloride Bromomethane Chloroethane Trichlorofluoromethane Acrolein 1,1-Dichloroethene Acetone Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene 2-Butanone Bromochloromethane Chloroform 1,1,1-Trichloroethane
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water
Sampled: Jun-09-22 11:17
Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
U
2.00
ug/L
1
B22F058
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
Result 9.55 10.1 10.1 10.7
%REC 94.9% 99.8% 101% 107%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared Jun-15-22
" " " "
Prepared " " " "
Analyzed Jun-17-22
" " " "
Analyzed " " " "
Matrix: Water
Sampled: Jun-09-22 11:50
Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
U
(ICV), (LCS),
L
U
(LCS), L
2.00
ug/L
2.00
"
1
B22F058
"
"
U
(LCS), L
2.00
"
"
"
U
(LCS), L
2.00
"
"
"
U
(ICV), L
2.00
"
"
"
U
2.00
"
"
"
2.02
2.00
"
"
"
U
2.00
"
"
"
28.5
10.0
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
10.0
"
"
"
U
2.00
"
"
"
12.5
2.00
"
"
"
U
2.00
"
"
"
Prepared
Jun-15-22
" " " " " " " " " " " " " " " " " " " "
Analyzed
Jun-17-22
" " " " " " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 13 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
2A (2206006-02RE1)
Analyte
Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water
Sampled: Jun-09-22 11:50
Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
U
2.00
ug/L
1
B22F058
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
4.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
4.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
4.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
Prepared
Jun-15-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Analyzed
Jun-17-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 14 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
2A (2206006-02RE1)
Analyte p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
Trip Blank (2206006-03RE1)
Analyte Dichlorodifluoromethane
Chloromethane Vinyl chloride Bromomethane Chloroethane Trichlorofluoromethane Acrolein 1,1-Dichloroethene Acetone Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water
Sampled: Jun-09-22 11:50
Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
U
2.00
ug/L
1
B22F058
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
Result 10.5 11.0 9.64 9.18
%REC 104% 109% 96.4% 91.8%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared Jun-15-22
" " " " " " " "
Prepared " " " "
Analyzed Jun-17-22
" " " " " " " "
Analyzed " " " "
Result
U
U U U U U U U U U U U U U U U U
Matrix: Water
Flags / Qualifiers
(ICV), (LCS), L
(LCS), L (LCS), L (LCS), L (ICV), L
Sampled: Jun-09-22 11:55
MDL
Reporting Limit
Units
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
10.0
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
Received: Jun-09-22 17:36
Dilution
1
" " " " " " " " " " " " " " " "
Batch
B22F058
" " " " " " " " " " " " " " " "
Prepared
Jun-15-22
" " " " " " " " " " " " " " " "
Analyzed
Jun-17-22
" " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 15 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Trip Blank (2206006-03RE1)
Analyte
2-Butanone Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Result
U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U
Matrix: Water
Flags / Qualifiers
Sampled: Jun-09-22 11:55
MDL
Reporting Limit
Units
10.0
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
Received: Jun-09-22 17:36
Dilution
1 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Batch
B22F058 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Prepared
Jun-15-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Analyzed
Jun-17-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 16 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Trip Blank (2206006-03RE1)
Analyte tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
Manhole D (2206006-04RE1)
Analyte Acrolein Acetone 2-Butanone
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Result
U U U U U U U U U U U U U
Matrix: Water
Flags / Qualifiers
Sampled: Jun-09-22 11:55
MDL
Reporting Limit
Units
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
Received: Jun-09-22 17:36
Dilution
1 " " " " " " " " " " " "
Batch
B22F058 " " " " " " " " " " " "
Prepared
Jun-15-22 " " " " " " " " " " " "
Result 10.8 11.0 9.64 9.13
%REC 107% 109% 96.4% 91.3%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared " " " "
Analyzed Jun-17-22
" " " " " " " " " " " "
Analyzed " " " "
Result 676 2380 665
Matrix: Water
Flags / Qualifiers
Sampled: Jun-09-22 12:10
MDL
Reporting Limit
Units
40.0
ug/L
200
"
200
"
Received: Jun-09-22 17:36
Dilution 20 " "
Batch B22F058
" "
Prepared Jun-15-22
" "
Result 10.6 11.0 9.77 9.85
%REC 105% 109% 97.7% 98.5%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared " " " "
Analyzed Jun-17-22
" "
Analyzed " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 17 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Manhole D (2206006-04RE2)
Analyte
Dichlorodifluoromethane
Chloromethane Vinyl chloride Bromomethane Chloroethane Trichlorofluoromethane 1,1-Dichloroethene Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB)
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Result
U
6.73 U U U U U U U U U U U U U U U U U U
10.5 U U U U U U 11.6
2.74 U U U U 165 U U
Matrix: Water
Flags / Qualifiers
(ICV), (LCS), L
(LCS), L (LCS), L (LCS), L (ICV), L
Sampled: Jun-09-22 12:10
MDL
Reporting Limit
Units
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
Received: Jun-09-22 17:36
Dilution
1
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Batch
B22F058
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Prepared
Jun-15-22
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Analyzed
Jun-17-22
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 18 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Manhole D (2206006-04RE2)
Analyte
Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Result
U U U U U 6.14 U U U U U U U U U U U U U U U U U U U U U U
Matrix: Water
Flags / Qualifiers
Sampled: Jun-09-22 12:10
MDL
Reporting Limit
Units
2.00
ug/L
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
Received: Jun-09-22 17:36
Dilution
1 " " " " " " " " " " " " " " " " " " " " " " " " " " "
Batch
B22F058 " " " " " " " " " " " " " " " " " " " " " " " " " " "
Prepared
Jun-15-22 " " " " " " " " " " " " " " " " " " " " " " " " " " "
Result 9.54 9.57 9.90 10.6
%REC 94.8% 94.9% 99.0% 106%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared " " " "
Analyzed
Jun-17-22 " " " " " " " " " " " " " " " " " " " " " " " " " " "
Analyzed " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 19 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
3A (2206006-05RE1)
Analyte
Dichlorodifluoromethane
Chloromethane Vinyl chloride Bromomethane Chloroethane Trichlorofluoromethane Acrolein 1,1-Dichloroethene Acetone Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene 2-Butanone Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water Sampled: Jun-09-22 12:32 Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
U
(ICV), (LCS),
L
U
(LCS), L
2.00
ug/L
2.00
"
1
B22F058
"
"
U
(LCS), L
2.00
"
"
"
U
(LCS), L
2.00
"
"
"
U
(ICV), L
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
31.5
10.0
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
10.0
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
4.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
Prepared
Jun-15-22
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Analyzed
Jun-17-22
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 20 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
3A (2206006-05RE1)
Analyte
2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water Sampled: Jun-09-22 12:32 Received: Jun-09-22 17:36
Result
Flags / Qualifiers
MDL
Reporting Limit
Units
Dilution
Batch
U
4.00
ug/L
1
B22F058
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
4.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
U
2.00
"
"
"
Result 10.3 10.9 9.71 9.82
%REC 102% 108% 97.1% 98.2%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared
Jun-15-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Prepared " " " "
Analyzed
Jun-17-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Analyzed " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 21 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
DAF (2206006-06RE4)
Analyte Acrolein Acetone 2-Butanone
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
DAF (2206006-06RE5)
Analyte Dichlorodifluoromethane
Chloromethane Vinyl chloride Bromomethane Chloroethane
Trichlorofluoromethane 1,1-Dichloroethene Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water
Result
Flags / Qualifiers
494 2330 610
Sampled: Jun-09-22 12:55
MDL
Reporting Limit
Units
40.0
ug/L
200
"
200
"
Received: Jun-09-22 17:36
Dilution 20 " "
Batch B22F058
" "
Prepared Jun-15-22
" "
Result 10.2 10.4 9.53 10.1
%REC 101% 103% 95.3% 101%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared " " " "
Analyzed Jun-17-22
" "
Analyzed " " " "
Matrix: Water
Result
Flags / Qualifiers
Sampled: Jun-09-22 12:55
MDL
Reporting Limit
Units
U
(ICV), (LCS),
L
13.2
(LCS), L
2.00
ug/L
2.00
"
U
(LCS), L
2.00
"
U
(LCS), L
2.00
"
U
(ICV), (LCS),
L
U
2.00
"
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
U
2.00
"
18.0
2.00
"
U
2.00
"
Received: Jun-09-22 17:36
Dilution 1
" " " "
" " " " " " " " " " " " " " " " "
Batch B22F058
" " " "
" " " " " " " " " " " " " " " " "
Prepared Jun-15-22
" " " "
" " " " " " " " " " " " " " " " "
Analyzed Jun-17-22
" " " "
" " " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 22 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
DAF (2206006-06RE5)
Analyte
Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water
Result
Flags / Qualifiers
U U U U U 5.08 4.57 U U U U 170 U U U U U U U 9.71 U U U U U U U U U U U U U 2.61 U U 2.77
Sampled: Jun-09-22 12:55
MDL
Reporting Limit
Units
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
Received: Jun-09-22 17:36
Dilution
1 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Batch
B22F058 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Prepared
Jun-15-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Analyzed
Jun-17-22 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 23 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
DAF (2206006-06RE5)
Analyte 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene
Surrogate Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) US EPA Region 5 LSASD Analytical Services Branch
Matrix: Water
Result
Flags / Qualifiers
U U U U U
Sampled: Jun-09-22 12:55
MDL
Reporting Limit
Units
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
Received: Jun-09-22 17:36
Dilution
1 " " " "
Batch
B22F058 " " " "
Prepared
Jun-15-22 " " " "
Result 9.34 9.29 10.1 10.5
%REC 92.8% 92.1% 101% 105%
%REC Limits 70-130
70-130
70-130
70-130
Batch " " " "
Prepared " " " "
Analyzed Jun-17-22
" " " "
Analyzed " " " "
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 24 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Batch B22F058 - Volatiles
Blank (B22F058-BLK1)
Analyte Dichlorodifluoromethane Chloromethane Vinyl chloride Bromomethane Chloroethane Trichlorofluoromethane Acrolein 1,1-Dichloroethene Acetone Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene 2-Butanone Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Result U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U
Flags / Qualifiers (ICV), L
(ICV), L
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
10.0
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
10.0
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
%REC
%REC Limits
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 25 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
Blank (B22F058-BLK1)
Analyte trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene
Result U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U
Flags / Qualifiers
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
%REC
%REC Limits
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 26 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
Blank (B22F058-BLK1)
Analyte Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
Blank (B22F058-BLK2)
Analyte Dichlorodifluoromethane Chloromethane Vinyl chloride Bromomethane Chloroethane Trichlorofluoromethane Acrolein 1,1-Dichloroethene Acetone Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene 2-Butanone Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride
Result U U U
10.8 11.1 9.65 8.86
Result U U U U U U U U U U U U U U U U U U U U U U
Flags / Qualifiers
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
2.00
"
2.00
"
"
10.06
"
10.08
"
10.00
"
10.00
%REC
%REC Limits
107% 110% 96.5% 88.6%
70-130 70-130 70-130 70-130
RPD
Flags / Qualifiers (ICV), L
(ICV), L
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
10.0
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
10.0
"
2.00
"
2.00
"
2.00
"
2.00
"
%REC
%REC Limits
RPD
RPD Limit
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 27 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
Blank (B22F058-BLK2)
Analyte 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane
Result U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U
Flags / Qualifiers
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
4.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
%REC
%REC Limits
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 28 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
Blank (B22F058-BLK2)
Analyte tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
LCS (B22F058-BS1)
Analyte Dichlorodifluoromethane Chloromethane Vinyl chloride Bromomethane Chloroethane Trichlorofluoromethane Acrolein 1,1-Dichloroethene Acetone Carbon disulfide Methylene chloride Acrylonitrile
Result U U U U U U U U U U U U U
10.9 11.6 9.92 8.62
Flags / Qualifiers
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
2.00
"
"
10.06
"
10.08
"
10.00
"
10.00
%REC
%REC Limits
108% 115% 99.2% 86.2%
70-130 70-130 70-130 70-130
RPD
RPD Limit
Result 4.44 11.9 17.0 18.2 21.8 26.0 13.4 25.5 143 32.9 27.4 28.8
Flags / Qualifiers (ICV), L, Q
Q Q
(ICV), L
Q
Q
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
10.0
"
125.0
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
%REC 17.8% 47.6% 68.1% 72.8% 87.3% 104% 53.6% 102% 114% 132% 110% 115%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 29 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
LCS (B22F058-BS1)
Analyte trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene 2-Butanone Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene
Result 26.4 25.5 27.2 26.6 25.8 129 25.5 26.7 26.8 27.5 26.1 26.3 27.7 26.3 27.0 26.2 26.9 25.9 51.3 25.5 24.8 24.4 24.1 24.4 49.2 24.8 24.1 24.4 23.7 24.5 50.4 24.6
Flags / Qualifiers
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
10.0
"
125.0
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
4.00
"
50.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
4.00
"
50.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
4.00
"
50.00
2.00
"
25.00
%REC 106% 102% 109% 106% 103% 103% 102% 107% 107% 110% 105% 105% 111% 105% 108% 105% 108% 104% 103% 102% 99.3% 97.4% 96.3% 97.4% 98.5% 99.1% 96.3% 97.5% 95.0% 97.9% 101% 98.3%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 30 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
LCS (B22F058-BS1)
Analyte Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
Result 24.5 24.2 24.7 24.5 24.5 25.3 25.7 25.4 25.8 23.8 24.3 25.4 25.1 24.8 24.7 24.8 24.4 25.4 23.2 22.8 24.8 22.5 23.6 10.1 10.5 10.5 10.4
Flags / Qualifiers
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
"
10.06
"
10.08
"
10.00
"
10.00
%REC 98.0% 96.8% 98.7% 97.9% 97.8% 101% 103% 101% 103% 95.2% 97.2% 102% 100% 99.3% 98.7% 99.4% 97.8% 101% 92.7% 91.0% 99.2% 90.2% 94.3% 100% 104% 105% 104%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 31 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Batch B22F058 - Volatiles
LCS (B22F058-BS2)
Analyte Acrolein Acrylonitrile Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
LCS (B22F058-BS3)
Analyte Dichlorodifluoromethane Chloromethane Vinyl chloride Bromomethane Chloroethane Trichlorofluoromethane Acrolein 1,1-Dichloroethene Acetone Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene 2-Butanone Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Result 31.0 30.0 10.8 11.1 9.73 8.88
Flags / Qualifiers
MDL
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
"
10.06
"
10.08
"
10.00
"
10.00
%REC 124% 120% 107% 110% 97.3% 88.8%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Result 4.12 10.1 15.2 14.3 17.0 25.8 22.2 26.0 126 30.6 25.7 25.5 25.6 25.9 25.2 26.5 25.2 116 25.2 25.1 26.4 26.2 25.4
Flags / Qualifiers (ICV), L, Q
Q Q Q (ICV), L, Q
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
10.0
"
125.0
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
10.0
"
125.0
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
%REC 16.5% 40.6% 60.6% 57.1% 68.2% 103% 88.7% 104% 101% 122% 103% 102% 102% 104% 101% 106% 101% 93.2% 101% 101% 106% 105% 102%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 32 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
LCS (B22F058-BS3)
Analyte Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene
Result 24.5 25.1 25.5 24.9 25.0 25.2 25.0 49.0 24.9 24.8 23.2 24.4 23.3 48.2 24.1 23.6 24.2 23.6 24.9 50.4 25.0 24.7 23.6 25.0 25.0 22.5 24.4 24.8 24.5 24.9 22.0 24.7
Flags / Qualifiers
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
4.00
"
50.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
4.00
"
50.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
4.00
"
50.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
%REC 98.2% 100% 102% 99.7% 100% 101% 100% 98.1% 99.5% 99.1% 92.7% 97.6% 93.2% 96.4% 96.4% 94.2% 97.0% 94.3% 99.5% 101% 100% 98.7% 94.6% 99.9% 100% 89.8% 97.5% 99.2% 98.1% 99.6% 87.9% 98.9%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 33 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Batch B22F058 - Volatiles
LCS (B22F058-BS3)
Analyte 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
LCS (B22F058-BS4)
Analyte Acrolein Acrylonitrile Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
LCS Dup (B22F058-BSD1)
Analyte Dichlorodifluoromethane Chloromethane Vinyl chloride
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Result 24.4 24.5 24.6 24.1 24.4 24.6 23.2 23.1 23.8 23.8 23.8 23.6 9.76 9.48 10.3 10.4
Flags / Qualifiers
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
"
10.06
"
10.08
"
10.00
"
10.00
%REC 97.6% 98.0% 98.3% 96.4% 97.8% 98.4% 92.7% 92.5% 95.3% 95.1% 95.3% 94.4% 97.0% 94.1% 103% 104%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Result 27.6 25.7 10.0 10.2 10.1 9.91
Flags / Qualifiers
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
"
10.06
"
10.08
"
10.00
"
10.00
%REC 111% 103% 99.9% 101% 101% 99.1%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Result 4.40 11.5 16.9
Flags / Qualifiers (ICV), L, Q
Q Q
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
2.00
"
25.00
%REC 17.6% 46.1% 67.6%
%REC Limits 70-130 70-130 70-130
RPD 1.09 3.26 0.731
RPD Limit
30 30 30
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 34 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Batch B22F058 - Volatiles
LCS Dup (B22F058-BSD1)
Analyte Bromomethane Chloroethane Trichlorofluoromethane Acrolein 1,1-Dichloroethene Acetone Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene 2-Butanone Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Result 15.8 19.5 26.1 14.3 26.4 141 33.1 27.3 28.5 27.0 26.1 27.3 27.3 25.7 125 24.8 26.8 27.5 27.3 26.6 26.2 27.1 26.4 26.6 26.2 26.7 26.0 50.4 26.0 24.8 24.2 24.3
Flags / Qualifiers
Q (ICV), L
Q
Q
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
10.0
"
125.0
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
10.0
"
125.0
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
4.00
"
50.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
%REC 63.3% 78.1% 104% 57.0% 105% 113% 132% 109% 114% 108% 105% 109% 109% 103% 99.8% 99.1% 107% 110% 109% 106% 105% 109% 106% 107% 105% 107% 104% 101% 104% 99.4% 97.0% 97.1%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD 13.9 11.2 0.176 6.22 3.40 1.29 0.400 0.482 1.17 1.95 2.35 0.448 2.65 0.148 3.10 2.81 0.0374 2.43 0.634 1.59 0.511 2.04 0.485 1.48 0.0763 0.790 0.200 1.63 1.83 0.121 0.444 0.811
RPD Limit
30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 35 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Batch B22F058 - Volatiles
LCS Dup (B22F058-BSD1)
Analyte 1,3-Dichloropropane 2-Hexanone Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Result 24.7 49.4 24.3 23.8 24.7 24.3 25.2 51.0 25.2 25.1 23.3 25.6 24.9 24.1 25.5 26.3 25.2 25.8 23.6 25.2 25.5 25.5 24.9 24.7 24.9 24.6 24.8 23.3 23.4 23.8 23.3 23.6
Flags / Qualifiers
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
4.00
"
50.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
4.00
"
50.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
2.00
"
25.00
%REC 98.7% 98.9% 97.3% 95.1% 98.8% 97.2% 101% 102% 101% 100% 93.1% 102% 99.4% 96.5% 102% 105% 101% 103% 94.2% 101% 102% 102% 99.6% 98.8% 99.5% 98.5% 99.3% 93.0% 93.6% 95.4% 93.1% 94.6%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD 1.33 0.434 1.78 1.24 1.35 2.37 2.80 1.17 2.32 2.31 3.89 3.52 1.54 1.38 0.763 2.43 0.681 0.202 1.01 3.76 0.314 1.82 0.306 0.130 0.105 0.774 2.14 0.362 2.82 3.96 3.20 0.246
RPD Limit
30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 36 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Batch B22F058 - Volatiles
LCS Dup (B22F058-BSD1)
Analyte Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
LCS Dup (B22F058-BSD2)
Analyte Acrolein Acrylonitrile Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
Matrix Spike (B22F058-MS1)
Analyte Acrolein Acetone 2-Butanone 2-Hexanone Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
Matrix Spike (B22F058-MS3)
Analyte Dichlorodifluoromethane
Chloromethane Vinyl chloride Bromomethane
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Result 9.75 10.0 10.2 10.4
Flags / Qualifiers
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
ug/L
10.06
"
10.08
"
10.00
"
10.00
%REC 96.9% 99.5% 102% 104%
%REC Limits 70-130 70-130 70-130 70-130
RPD
RPD Limit
Result 29.5 28.7 10.4 11.1 9.93 9.30
Flags / Qualifiers
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
2.00
"
25.00
"
10.06
"
10.08
"
10.00
"
10.00
%REC 118% 115% 103% 110% 99.3% 93.0%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130
RPD 4.80 4.65
RPD Limit
30 30
Source: 2206006-01RE3
Result
Flags / Qualifiers
MDL
1160
5050
3390
1300
10.0
10.5
10.6
10.5
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
40.0
ug/L
500.0
578
200
"
2500
2350
200
"
2500
611
80.0
"
1000
178
"
10.06
"
10.08
"
10.00
"
10.00
%REC 116% 108% 111% 112% 99.6% 104% 106% 105%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Source: 2206006-01RE4
Result
Flags / Qualifiers
2.98 (ICV), (LCS),
L, Q
15.8
(LCS), L, Q
15.1
(LCS), L, Q
13.7
(LCS), L, Q
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
U
2.00
"
25.00
6.83
2.00
"
25.00
U
2.00
"
25.00
0.638
%REC 11.9%
35.8% 60.5% 52.3%
%REC Limits 70-130
70-130 70-130 70-130
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 37 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
Matrix Spike (B22F058-MS3)
Analyte Chloroethane
Trichlorofluoromethane 1,1-Dichloroethene Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene
Source: 2206006-01RE4
Result
Flags / Qualifiers
17.3 (ICV), (LCS), L, Q
25.9
26.6
32.9
(LCS), K, Q
24.9
26.8
25.4
25.1
25.8
27.8
24.6
23.6
25.5
26.4
26.5
26.7
34.7
24.7
25.7
25.2
24.0
25.3
24.8
57.1
27.1
25.1
22.4
23.7
23.1
23.4
23.4
23.4
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
0.468
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
12.1
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
4.00
"
50.00
7.91
2.00
"
25.00
3.39
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
%REC 69.1%
104% 106% 132% 99.7% 107% 102% 100% 103% 111% 98.4% 94.4% 100% 106% 106% 107% 90.5% 98.7% 103% 101% 96.1% 101% 99.1% 98.4% 94.8% 100% 89.7% 94.8% 92.3% 93.6% 93.6% 93.8%
%REC Limits 70-130
70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 38 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Batch B22F058 - Volatiles
Matrix Spike (B22F058-MS3)
Analyte 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Source: 2206006-01RE4
Result
Flags / Qualifiers
23.1
25.1
49.7
24.8
29.7
23.9
25.1
23.1
23.9
24.8
24.2
24.2
24.7
23.3
25.2
25.8
25.5
24.3
25.8
23.8
24.0
26.1
27.7
24.5
24.9
27.2
23.6
9.39
9.56
10.2
10.7
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
U
2.00
"
25.00
0.842
4.00
"
50.00
1.54
2.00
"
25.00
U
2.00
"
25.00
6.84
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
0.736
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
1.45
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
1.69
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
1.01
2.00
"
25.00
U
"
10.06
"
10.08
"
10.00
"
10.00
%REC 92.4% 97.1% 96.4% 99.2% 91.6% 95.7% 100% 92.3% 95.7% 96.3% 96.8% 96.9% 98.7% 93.3% 101% 103% 102% 97.3% 97.5% 95.0% 95.9% 97.6% 111% 97.9% 99.5% 105% 94.4% 93.3% 94.8% 102% 107%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD
RPD Limit
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 39 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
Matrix Spike Dup (B22F058-MSD1)
Analyte Acrolein Acetone 2-Butanone 2-Hexanone Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
Matrix Spike Dup (B22F058-MSD3)
Analyte Dichlorodifluoromethane
Chloromethane Vinyl chloride Bromomethane Chloroethane
Trichlorofluoromethane 1,1-Dichloroethene Carbon disulfide Methylene chloride Acrylonitrile trans-1,2-Dichloroethene Methyl tert-butyl ether 1,1-Dichloroethane 2,2-Dichloropropane cis-1,2-Dichloroethene Bromochloromethane Chloroform 1,1,1-Trichloroethane Carbon tetrachloride 1,1-Dichloropropene
Source: 2206006-01RE3
Result
Flags / Qualifiers
MDL
1210
5040
3450
1300
9.93
10.2
10.5
10.3
Prepared & Analyzed: Jun-16-22
Reporting
Spike Source
Limit Units
Level Result
40.0
ug/L
500.0
578
200
"
2500
2350
200
"
2500
611
80.0
"
1000
178
"
10.06
"
10.08
"
10.00
"
10.00
%REC 127% 108% 114% 112% 98.7% 101% 105% 103%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD 4.71 0.217 1.67 0.0922
RPD Limit
30 30 30 30
Source: 2206006-01RE4
Result
Flags / Qualifiers
3.05 (ICV), (LCS),
L, Q
15.9
(LCS), L, Q
15.3
(LCS), L, Q
14.2
(LCS), L, Q
18.0 (ICV), (LCS), L
26.7
29.0
35.6
(LCS), K, Q
27.0
30.0
28.1
28.2
28.1
30.1
27.1
25.9
27.5
29.1
29.1
29.0
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
U
2.00
"
25.00
6.83
2.00
"
25.00
U
2.00
"
25.00
0.638
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
0.468
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
%REC 12.2%
36.2% 61.3% 54.3% 72.2%
107% 116% 142% 108% 120% 112% 113% 112% 120% 108% 104% 108% 117% 117% 116%
%REC Limits 70-130
70-130 70-130 70-130 70-130
70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD 2.25
0.657 1.35 3.57 4.33
3.15 8.96 7.86 8.04 11.4 10.0 11.6 8.55 7.77 9.61 9.47 7.45 9.74 9.36 8.40
RPD Limit
30
30 30 30 30
30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 40 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
Matrix Spike Dup (B22F058-MSD3)
Analyte Benzene 1,2-Dichloroethane Trichloroethene 1,2-Dichloropropane Dibromomethane Bromodichloromethane cis-1,3-Dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-Dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 1,3-Dichloropropane Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene 1,1,1,2-Tetrachloroethane Ethylbenzene m+p-Xylene o-Xylene Styrene Bromoform Isopropylbenzene Bromobenzene 1,2,3-Trichloropropane n-Propylbenzene 2-Chlorotoluene 1,3,5-Trimethylbenzene 4-Chlorotoluene 1,1,2,2-Tetrachloroethane tert-Butylbenzene 1,2,4-Trimethylbenzene
Source: 2206006-01RE4
Result
Flags / Qualifiers
37.0
27.0
28.0
27.3
26.3
27.6
27.2
64.9
29.5
27.8
25.2
26.2
25.7
26.2
26.2
25.9
25.7
27.5
54.7
27.3
32.4
27.3
27.5
25.8
26.9
27.0
26.5
26.2
27.1
26.2
27.5
28.0
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
12.1
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
4.00
"
50.00
7.91
2.00
"
25.00
3.39
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
0.842
4.00
"
50.00
1.54
2.00
"
25.00
U
2.00
"
25.00
6.84
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
0.736
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
%REC 99.6% 108% 112% 109% 105% 110% 109% 114% 104% 111% 101% 105% 103% 105% 105% 104% 103% 106% 106% 109% 102% 109% 110% 103% 108% 105% 106% 105% 108% 105% 110% 112%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD 6.36 9.18 8.70 8.23 8.88 8.36 9.43 12.8 8.48 10.3 11.5 10.1 10.9 11.4 11.3 9.91 10.6 8.92 9.54 9.45 8.75 13.0 9.24 11.1 11.8 8.39 9.10 7.81 9.23 11.5 8.84 8.16
RPD Limit
30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 41 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
Volatiles by GC/MS, EPA 8260C (modified) - Quality Control US EPA Region 5 LSASD Analytical Services Branch
Batch B22F058 - Volatiles
Matrix Spike Dup (B22F058-MSD3)
Analyte sec-Butylbenzene 1,3-Dichlorobenzene p-Isopropyltoluene 1,4-Dichlorobenzene 1,2-Dichlorobenzene n-Butylbenzene 1,2-Dibromo-3-chloropropane 1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene Surrogate: Dibromofluoromethane Surrogate: 1,2-Dichloroethane-d4 Surrogate: Toluene-d8 Surrogate: 4-Bromofluorobenzene
Source: 2206006-01RE4
Result
Flags / Qualifiers
27.5
26.5
27.7
26.3
26.5
27.3
32.0
26.5
27.4
30.0
26.0
9.28
9.28
10.1
10.7
Prepared: Jun-16-22 Analyzed: Jun-17-22
Reporting
Spike Source
MDL
Limit Units
Level Result
2.00
ug/L
25.00
U
2.00
"
25.00
U
2.00
"
25.00
1.45
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
1.69
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
U
2.00
"
25.00
1.01
2.00
"
25.00
U
"
10.06
"
10.08
"
10.00
"
10.00
%REC 110% 106% 105% 105% 106% 102% 128% 106% 109% 116% 104% 92.3% 92.1% 101% 107%
%REC Limits 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130 70-130
RPD 7.35 8.65 7.15 10.3 9.95 4.35 14.5 7.90 9.60 9.60 9.52
RPD Limit
30 30 30 30 30 30 30 30 30 30 30
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636
Page 42 of 43
Water Division, WECA Region 5 77 West Jackson Boulevard Chicago IL, 60604
Environmental Protection Agency Region 5
US EPA Region 5 LSASD Analytical Services Branch
536 South Clark Street, Chicago, IL 60605
Phone:(312)353-8370
Fax:(312)886-2591
Project: Vantage Olechemical Project Number: [none] Project Manager: Andi Hodaj
Reported: Jul-27-22 16:36
L
K
(LCS) (ICV) U NR Q
Notes and Definitions
The identification of the analyte is acceptable; the reported value may be biased low. The actual value is expected to be greater than the reported value. The identification of the analyte is acceptable; the reported value may be biased high. The actual value is expected to be less than the reported value. Blank spike recovery criteria not met for this analyte
Initial calibration verification criteria not met for this analyte
Not Detected Not Reported QC limit Exceeded
Report Name: 2206006 VOA - 8260 FINAL Jul 27 22 1636