Document JrDGBZEMjRzQMzMdwnnVz6bdr

Boilers, Gas L. J. Mueller Furnace Co. Established 1857 2009 W. Oklahoma Ave., Milwaukee, Wis. Gas-Era Gas-Fired Boilers Adaptable for steam or hot water heating. Completely automatic operation. Cast iron construction for durability, with asbestoslined metallic jacket. Vertical burner adjustment permits use with any manufactured or natural gas. Have steady water line and will not prime. Interior surfaces may be thoroughly cleaned without disturbing jacket. Multiple unit con struction permits increase in size when desired. Boiler is highly efficient, securing maximum heat utilization with minimum gas consumption. HOT WATER Boiler No. A.G.A. Rating 13-W 24-W 25-W 36-W 37-W 49-W 5II-W 613-W 715-W 817-W 919-W 1021-W 1123-W 1225-W 1327-W 1429-W I53I-W 1634-W 1838-W 2042-W 2246-W 2450-W 2654-W 2858-W 3062-W 670 1.005 1,340 1,675 2.010 2.680 3,350 4,020 4,690 5,360 6,030 6,700 7,370 8.040 8,710 9,380 10,050 10,720 12,060 13,400 14,740 16,080 17,420 18,760 20,100 STEAM Boiler No. A.G.A. Rating 13-S . 24-S 2S-S 36-S 37-S 49-S 511-5 613-S 715-S 817-S 919-5 1021--S 1123--S 1225-S 1327-S 1429-S 1531--S 1634-S 1638-S 2042-S 2246-S 2450-S 2654-S 2858-S 3062-S 420 630 840 1,050 1,260 1,680 2.100 2.520 2,940 3.360 3,780 4,200 4,620 5,040 5.460 5,880 6,300 6,720 7,560 8.400 9,240 10.080 10,920 11.760 12.600 Floor Space Inches 31'/,. 46% 35'/,. 46% 39 . 47% 43 x 5F/a sa a46%. 5i% 70 > 51% 793,4 X 53VS 873/2 x 53% 95%. 54% 103 . 54% 110%. 56'/, 136 . 54% 143%. 54% 87% 1 I07>/, 95% . 109% 103 . 109% 110%. 112% I20V2 * 107/4 M136Wi * 1 110099V%2 14334 x mA VENTS Number Diameter Inches 4 16 17 19 19 1 10 1 11 29 2 10 2 10 2 II 2 11 2 12 3 10 3 3 II 3 11 2 14 2 16 2 16 2 17 3 14 3 16 3 16 3 16 Gas-Era Gas-Fired Water Heaters Adaptable for heating of water in considerable volume. May be used as direct or indirect systems. Automatic operation. _________________ Boiler No. Gal. Heated per Hour, 25 Rise Gal. Heated per Hour, 40 Rise Gal. Heated per Hour, 100 Rise Gal. Heated per Hour. 140 Rise 13 24 25 36 37 . 49 511 613 715 817 919 1021 1123 1225 1327 1429 1531 485 728 970 1,213 1,455 1,940 2,425 2.910 3.395 3,880 4,365 4,850 5,335 5,820 6.305 6,790 7,275 303 455 606 758 909 1,212 1,515 1,818 2,121 2,424 2.727 3,030 3,333 3,636 3,939 4,242 4.545 121 181 242 303 364 485 606 728 849 971 1,091 1,212 1,334 1,455 1,576 1,697 1,819 Complete descriptive and illustrated catalog on request. 658 86 129 172 215 259 345 432 518 605 691 779 665 951 1,038 1,124 1,211 1,298 Required 1 1 *`/4 Wl 21% 2 22y/2t 2/2 i2/2 2/2 3 3 3 3 3 4 4 4 4 5 5 Boilers, Steel THE BABCOCK Be. WILCOX COMPANY 85 Liberty Street, New York, N. Y. Water-Tube Boilers Oil Burners Manufacturers of Chain-Grate Stokers , Seamless Steel Tubing and Pipe Branch Offices and Representatives in all Principal Cities Type H Stirling Boiler The Babcock & Wilcox Type H Stirling Boiler is a highly efficient unit built for moderate pressures at moderate prices.. . . and is designed to occupy minimum floor space and head room for the heating sur face required. This boiler is built in four classes and 36 sizes ranging from 714 to 5071 sq. ft. of heating surface, and can be designed for operation with any fuel and every method of firing. The moderate price is due only to the simplicity of design, efficient production methods and superior shop equipment. The advantages of the Babcock & Wilcox 1Depth of Setting. 1 Ft.. In. 1 Floor to Center of Mud Drum, Ft.. In. Floor to Face of' Steam Outlet, Ft.. In. Floor to Top of Boiler, Ft.. In. Size of Steam Outlet, In. 2 1 CO I Jl O Widthof Setting Two Single Boilers Boiler. in Ft.. In. battery Fl. In. 8714 15-T 6-0 11-0 5-2 952 7-0 13-0 8119(1 * 6-0 15-0 H-1 I42fl 9-0 17-0 8 1666 KM) 19-0 8 1904 8 11-0 21-0 8 7142 12-0 23-0 8 2380 8 13-0 25-0 14-5% 14-2% 88 " 88 88 8" 900 17-8 6-0 170(1 7-0 1500 8-0 H-2 \m 9-0 ?.m 8 10-0. 87400 11-0 7700 12-0 3000 * 13-0 11-0 13-0 15-0 17-0 19-0 21-0 23-0 25-0' 4-9% 14-5% 14-2% 8 888 88" 8 88 "8 88 1086 20-7 6-0 144* 7-0 Iftlf 8-0 7172 9-0 H-1 2534 8 10-0 7896 11-0 3251 12-0362C 13-0 3987 14-0 4344 * 15-0 11-0 13-0 15-0 17-0 19-0 21-0 23-0 25-0 27-0 29-0 84-5% 14-5% 14-2% 8 8 88 88 8 88 1768 22-8 6-0 m 7-0 7i n 8-0 2535 9-0 2951 10-0 3381 " 11-0 380: 12-0 4776 13-0 84641 14^0 85071 15-0 11-0 4-1% 14-11 14-5% 13-0 0 15-0 8 8 8 17-0 " 8 8 19-0 21-0 23-0 25-0 27-0*~ 29-0 888 * * 888888 888888 885 888 8 " 5 8 8 8 8 88 " 58 8 8 " 8 8 8 6 6 5 8 8 8 8888 6 6 Type H Stirling Boiler with Babcock <fc Wilcox Chain-Grate Stoker Type H Stirling Boiler may be sum marized as follows: Unusual steaming capacity for the floor space and head-room required. Boilers may be set singly or in battery. Setting heights can be varied to suit any condition of firing. The choice of three locations for gas exit reduces cost of flues and breeching. Distribution baffies make effective all of the heating surface. Tube renewal is facilitated by correct tube spacing, and a tube removal door. Soot blowers can be readily installed to simplify thorough cleaning of all tubes. A superheater can be furnished with out any change in the standard design or construction. The boiler is supported by a structuralsteel framework entirely independent of the brickwork. Ample provision is made for free movement of parts due to expansion and contraction. A complete table of sizes and dimensions, together with pertinent installation data, is contained in a new thirty-two page bulletin which will be sent upon request. Simply ask for Bulletin G-8-A. 659 i