Document EdrdRb7v5D60J13X03rgwpkr0

i. ` ! "w -- ELECTRONICS....HYDRAULICS....HEAT TRANSFER-------LUBRICATION NUCLEONICS____ SONICS_____COOLANTS .... DIELECTRICS; Monsanto Specialized Fluids and new FluiDesign Service can help you benefit from 0222793 Conventional fluids (water, oil) impose well-known restrictions on engineer ing designs. Heat, radiation, fire hazard, shear, electrical requirements, extreme pressure, friction--all cause problems--limit you in design flexibility, in imaginative thinking, in new ideas. Monsanto's specialized synthetic fluids--chemically tailored to minimize many design restrictions in power transmission, lubrication, heat transfer, insulation, cooling--make new and improved designs practical. Spawned by advances in specialized fluid properties and broadening of fluid functions-- a renaissance in engineering concepts is starting now. These specialized fluids open new design opportunities for your exploration. Monsanto's new FluiDesign Service--established to help you meet your needs best from the capabilities of some thirty specialized fluids--can give you valuable guidance at the outset of your design exploration and engineer ing planning. For example, the next two pages provide you with the FluiDesign Service Report, "Fire-Resistant Fluids for New Mechanical Applications." Among the fifteen fluids described, one or more may allow you to engineer your next design for safer, more efficient performance. Be sure to eet your fact-packed Fluid Data File... TOWOLDMON0047956 WATER_PCB-00035175 o f 1 1 ; i j f ) 1. \ s o i i From Monsanto FluiDcsign Service.. The fifteen fire-resistant fluids described here are now at work in industrial and aircraft hydraulics, hent transfer and other mechan ical applications which require a firesafe fluid. When you need a fire-resistant fluid for any application, one of these Monsanto special ized fluids may be adaptable to your job. Consider how these and other specialized fluids might solve special-design engineering problems for you. If one of these fifteen does not meet your present requirements, Monsanto FluiDesign Service will make other recommendations for your application. Just send a brief description of tne condi tions which your fluid must meet. For the specific properties you need, only Monsanto can make and help you select from so many kinds of specialized fluids, including Flash point, F., Cleveland Open Cup Fire point, F., Cleveland Open Cup Autoignition temp., F. Viscosity, cs. 100F. 210F. Pour point, F. Boiling point, F. 760 mm. Hg Skydrol 7000 425 Skydrol 500A 360 Pydraul 60 435* Pydraul 150 380 Pydraul F-9 430 Pydraul A-200 380* 475 1050" 425 >1100* 460 >1000 470 >1100 675 >1100 680 >1200 15.5 4.00 <-70* 11.5 3.92 <-85 11.1 2.65 -70 30.8 8.0 -55* 47 5.5 -5' 49.5 4.6 toff 709" ' -- 707 617* 644 820" Max. bulk temp., F. . long term - 200" 225 200 200 300 300 Coefficient of thermal expansion, per F. I 0.00042 0.00045 -- 0.00042 0.00041 0.00040 Specific heat, 25C. 0.42 0-38 0.42 0.40 0.32 0.28 Thermal conductivity Btu/hr./ft.*/ft./F. 0.0723 0.0777 0.047 0.070 0.067 0.059 Bulk modulus, psl 328,000 308,000 328,000 319,000 387,000 400,000 Specific gravity, 25/25C. 1.08 HOT 1.09 1.13 1.28 1.42 Resistivity, ohm-cm, 25C. 5 x 10* 4x10' -- _ 1.5 x 10' 3.3 x 10" Dielectric strength, 25C., 60 cps., 0.1 in. 36KV 12KV _ -- 33KV 38KV Dielectric constant, 25C., 1000 cps. 8.87 8.81 -- 6.25 -- Power factor, % 1000 cps., 25C. 0.49 -- -- -- 2.2 -- Original use \ 1 . aircraft aircraft industrial Industrial Industrial Industrial hydraulics hydraulics hydraulics hydraulics hydraulics hydraulic 0222794 60-OMC-2764 Machine Design, October 27 and Dccei -- . . . -- ... TOWOLDMON0047957 WATER PCB-00035176 phosphate esters, silirate esters, diphenyl and terphenyl and chlorinated derivatives. Monsanto has the best facilities and broadest know-how for making the widest variety of fluid "base'* stocks and additive modifiers of any chemical manufacturer. Whatever your requirements, consult Monsanto if you need a fluid for a new product or machine-de sign concept. Wnte: MONSANTO CHEMICAL CO. Organic Chemicals Division FluiDesign Service, Dept. 2764A St Louis 66, Missouri wrote*. PYDtAUL. AtOClOt: MwwM T.AU,ts. U.&.P0I. Off. Pydraul Pydraul OS-1 Aroclor Aroclor Aroclor Aroclor Aroclor Transforms ; 625 AC 1221 1232 1242 1248 1254 Askare! ? 465 420 - 205 308 360 379 - 460 ; 745* 050" . - 340 460 >610 >640 >660 460* >1100* 1100 1100* >1000* >1100 >1200 >1200 >1200 1000 11 !, ,3S 882 35.25 4.6 6.0 172 452 500 6.0 ; At 5.15 3.18 12 <12 22 32 6.14 12 ; so 80 15 34 -32 2" 20* 60 47 ; 724* 668* - 527 654* 617 644 689 460 j oo" 300 300 600 600 600 600 600 600 ! - 0.00040 - 0.00039 0.00040 0.00038 0.00039 0.00037 0.00039 - 021 023 021 029 027 026 025 0.065 >75,000 - 375,009 - 0267 - 0263 - 0.058 - 0.057 428,000 0254 - 0.050 - 1.36 1.35 1.40 1.18 126 128 1.45 124 127 1 i { _ - - . 1 x 10" 1 10" 1 x 10" 1 x 10" 1 x 10" 3x10" < - -' >35KV >35KV >35KV >35KV >35KV 35KV i' j_ -- - 4.6 3.4 SI 5.6 5.0 4.0 r. - - <0.1 <0.1 <0.1 <0.1 <0.1 0.1 i Industrial air- turbine and plasticizer plasticizer capacitor heat capacitor transformer ; hydraulics compressor compressor impregnant; transfer impregnant dielectric !. ! lubrication lubricant -- heat transfer ,; Product Engineering, October 24 and November 28, I960. 02 227^ TOWOLDMON0047958 WATER PCB-00035177