Air Conditioning W. L. Fleisher & Co., Inc. 31 Union Square West New York, N. Y. * Chicago, 111., 530 South Clinton St. Philadelphia, Pa., 135 North 3rd St. Consulting and Contracting Industrial Engineers for Air Conditioning and Drying Slurlevaril --FTeisher AIR CONDITIONING SYSTEMS Slurtcvanl-Fleisher Equipment The Sturtevant-Fleisher air conditioning systems are designed to Overcome the . handicaps imposed on industry by variations in, or adverse climactic, weather or atmos pheric conditions. They insure to the manufacturer that effect on materials and pro cesses which can only be produced by ideal air characteristics, making his plant entirely independent of the seasons or the weather. ^ Whether the cure for such difficulties involves the creation of high or low tempera ture, and high or low humidities in any combination, dependable apparatus, a careful design and a broad basis of experience, is offered by the combined Sturtevant and . Fleisher organizations. All apparatus used is manufactured by the B. F. Sturtevant Co., the oldest, largest and one of the most experienced fan and air apparatus builders in this country. The highest type of service, both from the engineering and contracting viewpoints, is assured by W. L. Fleisher & Co., Inc. Catalogs are ready for distribution, giving both the general details of the apparatus used, and also, for each specific industry, giving the particular advantages of such in stallations to that industry. Sales Engineers are located in practically every principal city. Upon request they , will call on manufacturers for consideration of their problems and to collect data for recommendations, estimates, and guarantees of results. 1 182 Air Washers The Cooling Tower Co., Inc. 17 John Street, New York AIR WASHERS COOLING TOWERS SPRAY NOZZLE SYSTEMS Representatives in Principal Cities The air washers tabulated below embody all the good features of the best modern practice and have been designed to meet the specifications of Architects and Engineers for public buildings. Some exclusive features are the special clog-proof' nozzles, the duplex spray heads with scale arrester, and automatic hu midity control devices. For information on washers for generators, ask for Bulletin K. AIR WASHERS FOR PUBLIC BUILDINGS Length T O'. Air Vei. gross area 480' per min. Resistance 0.2' water gage. Washer Num ber Total Width B- 5 B- 7 B- 9 B-l 1 3'-9" y-9* y-9* y-9* C- 7 C- 9 C-ll C-13 C-15 5'-6' 5'-6' 5'-6' 5'-6' 5'-6' D- 9 D-11 D-13 D-15 D-17 D-19 7'-3' 7'-3' 7'-3' 7'-3' 7'-3' 7'-3' E- 9 E-l 1 E-13 E-l 5 E-l 7 E-19 vjs 9'-0' vw 9'-' 9'-0' 9'-O' F--11 F-13 F--15 F-17 F-19 IO'-9' 1(Y-9* W-9* W-9* 10'-9* G-l 1 G-13 G-l 5 G-l 7 G-19 ir-3' 12'-3, 1\?2'.-3y' 12'-3' H-13 H-15 H-17 H-19 !4,-0' l4'-0' l4'-0' M'-O* 1-15 1 y-9* I--17 \y-9* I--19 iy-9* J-15 H/ J-19 l7'-6' !7'-6' !7'-6' K-15 K-17 K-19 W-l* l9'-3' w.y L-17 2P-0' L-19 2l'-0' Total Height Ca pacity Cubic Feet per Min. 4'-0'A' S'-ffA' 6'-0Vi` r-O'A' y-o'h' O'-0'A' T-O'/S O9`-'-oO'A'/'f b'-O'/f' r-o'A' O'-O'/f' 9,-0V2" 10,-0Vz" W-O'A' 6'-0VY r-O'A' O'-O'/S 9'JF/z* lO'-O'/i' 11'-0>/2' 4,500 6,000 8,000 10,000 9,200 12,000 15,000 17,200 20,000 15,800 20,000 22,800 26,400 30,000 33,400 20,000 24,200 28,600 33,000 37,500 42,000 r-O'A" 8'-O'A' r-O'A' lO'-OVz' H'-0/2' 30,000 35,000 40,000 45,000 50,200 r-O'A' 8'-0*/,' m/z" WJl'/S 1 r-0'A' 35,000 40,000 46,200 52,400 60,000 O'-O'/z' lO'-O'/z' ivws 46,000 53,000 60,000 67,000 9'-QVz0- 60,000 \QfJ/S 67,200 IV-O'/S 75,200 9'-0>/2' ww/s It'-0<A' 66,000 75,000 83,600 9'-Q'/S WJS'/S If-O'A' 72,600 82,200 92,000 JO'-OVi' 1 90,000 1 1 \`4f/S j 100.200 1 CIRCULATING PUMP Size Ca pacity G. P. M. Brake H. P. R. P. M. Motor H. P. t'/z " ww I'A' 1\w'/i w 1* 2' 22 30 40 48 46 60 73 86 100 LI 1,730 1.5 1,730 1.8 1,730 2.1 : .1,730 ; 2 2 2 3 2.0 1,730 3 2.5 1,730 3 3.0 1,720 5 2.7 1,720 5 3.2 1,720 5 IVY 2' 2' 2' 2" 2' I'A' 2'A' if/s 2'A' 2'A" 2<A' 2'A` 3' 3' W' 3y' 3' 3' 3' y 4' y 4' 4' 4' 4' 4' 4T 4' 4' 4' 4' 79 97 114 132 150 167 3.2 3.1 3.6 4.1 3.8 4.2 99 3.2 121 3.8 143 3.7 165 4.2 187 4.7 209 5.3 145 3.7 172 4.3 198 5.0 224 5.6 251 6.1 170 4.3 200 5.0 231 5.6 262 6.3 292 7.1 229 5.5 264 6.4 299 7.2 334 7.0 298 . 7.2 336 7.0 376 7.9 330 6.9 374 7.8 418 8.8 3o3 7.2 411 8.6 460 9.7 448 9.4 501 10.5 1,720 V.720 1,720 '1,720 1,720 1,720 5 5 5 5 5 5 1,720 1,720 1,720 1,720 1,720 1,750 5 5 5 5. 5 rA 1,720 1,720 1,750 1,750 1,750 5 5 r/z li 1,720 1,750 1,750 1,750 1,750 5 7'/z i 1,750 1,750 1,740 1,750 V/z V/z 10 2'A 1,740 1,750 1,740 10 7'A 10 1,750 1,740 1,740 V/z 10 40 1,740 1 10 l,740r 10 1,760 15 i1,760 15 1,760 IS PIPE CONNECTIONS Pump Dis charge Pump Suc tion Fresh Water Drain \1vV2s0 2' 2' Vw/z' T2* vVsS 2' 2' VS Y VS 2' w 2" 2* 2' VvSs 2* V 2` 2' vs 2" 2' 2". iv'/AS" vvss 2* 2' 2" 2' VS 2r 2r 2'/S 2VS 2x/z 3' V/S V/S V/S 3' 3' Vvvss," vvss 2* 2' 2' 2' 2' 2* V/S w y 2VS 2 VS 3' 3' vvvsss vs 2' 2' 2' 2' y y y y vvss 2' 2' V/S 3' 3' y 3' y 3' 4' 3' 4' y y y 3' y 4' 4' 4' 4' 4' VS vvss vvss 2' 2" 22' 2' r i'. r t- r V 2'A' y 4' 4' 4' 4' 4' 4' 4' \* r r 4' 4* 4' 4' 4' 5' 1' 1' r 4' 4' 4' 5' 4' 5' \* 2/S r -2VS i' 2'A" 4* 5' 1 VS 3' 4' 5' tvs 3' 5' 5' tvs y 4' 5' ly 1 5' t \ v/s t'/S |1 y 3" 183