Document 5kxkaNqVExoK1rZkk1k1X9jwJ
Hoffman Specially Co., Inc.
Specialties, Healing
TYPICAL INSTALLATION HOFFMAN "CONTROLLED HEAT" EQUIPMENT
-1 <> r*V irrn--i-i t-r nrwi m-4
TYPICAL HOTFMAN CONTROLLED HfAT INSTALLATION.
NOTB.--Loop discharge* into high end of return main. This results in seating airfrom high point in return instead of lout point. Point" W " should be at least Si in. above water line with Hoe. 0 and OS loops and 50 in. with Hoe. 05 and 04.
,The ..above drawing shows the typical application of Hoffman Products to a vapor-
vacuum system--Hoffman "Controlled Heat."
The.features of the No. 7 Adjustable Modulating Valve for balancing steam distribu
tion arid radiator output and the accuracy of No. 8-A or 18-A Traps in controlling flow
of condensation and air from the radiators without steam loss, positively control the
room temperature to meet the requirements of the occupant.
The basement specialties automatically control fuel consumption and protect the
boiler from loss of water through the returns, without thought or attention on the user's
part.
AV
"Controlled Heat" is adaptable and economically suited to any building where the required water line difference is available.
The No. 11 Vapor Vacuum Valve is used for venting the return mains
of vapor-vacuum systems or for other conditions where return of air
through vent port must be prevented. The vent port is % in. in diameter.
Pipe connection--% in. Maximum guaranteed operating pressure--
15 lbs.
No. 19 Quick Opening Radiator Valve
is of the semi-packless type for vacuum
pump installations or for vapor systems
where modulation is not required. Made in
% in. size only. Capacity--200 sq. ft. of
radiation.
Regularly furnished with lever handle.
Wood wheels or Lock Shields on special
order at no extra charge. Offset or straight
extended stems for concealed units on order
No. 19 Hoffman Radiator Valve
at small extra charge. Angle pattern only.
798
No. U
Hoffman Specialty Co., Inc.Specialties, Heating and Pumps.
HOFFMAN-ECONOMY RETURN LINE VACUUM PUMPS
The jet type vacuum producer used in these pumps is one of the simplest and best
known methods for exhausting air and vapors. It has no moving parts and avoids close
clearances so that loss of efficiency, due to wear, is reduced to a minimum. Pumps will
handle extremely hot water and are smooth and quiet in operation.
All units of 16,000 sq. ft. and over have horizontal split case pumps with enclosed,
double suction, bronze impellers. Units of 12,000 sq. ft. and under have vertically split
Vacuum Pumps
volute pumps, with enclosed impeller, re movable bronze stand bearing and outboard
Pump No.
Capacity
Sq. FL Dir. Cast Iron
Rad.
Water Cap.
G. P. M.
Air Cap. C. F. M.
Motor
H. P. 20. lb. Press.
ball bearing. Operation is controlled by float switch and vacuum regulator.
All sizes furnished in Duplex Units. When returns
SV-0
1,500
3
1 Y1' are below pump
SV-IA
3,500
7
3 Vs inlet an auxiliary
SV-2 SV-2A SV-3A
5,000 7,000 12,000
9 13
15
3I 4i
accumulator
7 I'A tank will permit
SV-4
16,000
22
92
operation on
SV-5 SV6 SV-7
20,000 26,000 40,000
28
35 60
12 3 15 5
21 5
float control only. All units
SV-8
65,000
90
34 J'A completely as
SV-9
100,000
140
50 10
SV-10 150,000 210 102 15
SV-11 250,000 350 130 25
sembled and wired ready for
installation.
pumps, 20 tbs.
HOFFMAN-ECONOMY HORIZONTAL CONDENSATION PUMPS
Horizontal Condensation Pumps are made in Styles "A"--0 to 20 lb. pressure--"B"--"C" and "D" for 35 to 100 lb. pressure. All units have bronze fitted, enclosed impellers. Styles A-B and C have vertically split case-- Style D horizontal split case. Style A pumps have out board ball bearing and self-lubricating, renewable bronze stand bearing. Style B and C have double outboard bear ings, ring oiling at driving end and ball bearing at opposite end, botn readily renewable. Style D has double outboard ring oiling bearings, both easily renewable.
Float switch mechanism is positive with bronze float arm supported by two liberal bearings. All units are completely assembled and wired, ready for installation.
Style" A"
Pump and Style No. Capacity Sq.Ft.
Dir. C .I.
Radiation Pump and | Style No. B Pump and Style No. Disc. Press. Lbs. Sq. In.
I0A
30A 31A 32A'
60A 6IA . 62A 64B 65B
65C 66B 66C 67B 67C 68C* 69C
Capacity Table--Condensation Pumps--60 Cycle and Direct Current
3-s
d0 u
.
I-aE
ii 1 **
Qj 0.0 SI
*
-.1
8-S Q. u
I^l SioJrod
ii Q-J
5& 0.0 2x
COE
>.
(S^TcStS
8- . u.
liaS 1:
i dd SI
fine
1.000 10 2
1.750 100A 10.000 101A 10,000
10 20 Vs 1.750 200A 20.000
15 20
1.750 20IA 20.000
10 40 Vi 1.750 15 40 Vs 1.750
3.000 3.000 3.000
10
15 20
k5 Vs 1.750 102A 10.000 20 20
5 'A 1.750 I03B 10.000 25 20
5
Vs 1.750
104B 105B
10,000 10.000
30 20 40 20
1.750 1.750
1.750 1.750
202A 203B
205B
20,000 20.000
20.000
20 40 1 1.750 25 40 I'/l 1.750 40 40 2 1.750
Wi6.000
6.000 6.000 6.000 6.000
10 15
20
30 40
86,000 8 l'/i6.000
6.000 6.000 - 6.000 6.000 6.000
40 50 50 60 60 75 100
12 Vs 1.750 12 'Os 1.750 12 1.750 12 1 1.750 12 v/2 1.750
12 l'/2 3.500 12 2 1.750 12 2 3.500 12 3 1.750 12 3 3.500 12 3 3,500 12 5 3,500
I05C 106B I06C I07B 107C I09C
151A 152A I53B 155B I55C I57B 157C I59C
10.000 10.000 10.000 10,000 10.000 10.000
15,000 15.000 15.000 15.000 15.000 15.000 15.000 15.000
-40 50 50 60 60 100
15 20 25 40 40 60 60 100
20 20 2 20 2 20 3 20 3 20 5
30 30 30 1 30 2 30 2 30 3 30 3 30 5
3.500 1,750 3.500
1,750
205C
207B 207C 209C
20.000 20.000
20,000 20,000
40 60
60 100
40 2 40 3 40 3 40 5
3.500 1.750
3.500 3.500
3.500 3.500
300A 301A
30.000 30.000
.10 15
53 53
1.750 302A 30.000 20 53 1
1-.750 303A 30.000 25 53
1.750
1.750 1.750 1.750 1.750
1.750 304A 30.000 30 53 2 1.750
3.500 307C 30.000 60 53 5 3.500
1.750 3.500
308C 309B
30.000 30,000
75 100
53 T/i 1.750 53 10 1.750
3.500
Complete Tables and Specifications for Pumps up to 70,000 sq. ft. capacity. Given in Our General Catalogue
799