Document 2qZ7KYbvMBy2zjQOkmvzaX9Mr

338 Ha System* im*k, sim) lAMERiCAN-v$tandard KEWANEE BOILER DIVISION 101 FRANKLIN STREET, KEWANEE, ILLINOIS KEWANEE STEEL BOILERS ARE CONSTRUCTED IN STRICT ACCORDANCE WITH ASME CODE. With ft history Of overQO successful years, Kewanee Boiler Division today provides a complete line of steel fire tube boilers, both high pressure and low pressure, for hf.p|i power "il process steam in installations from coast to coast and abroad. Both Scotch type and firebox boilers are manufactured, with a total of 36 sizes of Sachaired boiler-burner units for oil, gas and gas-oil combination firing. / our [cuonee Man is always available to provide complete literature and specifica tions . .. solve installation problems . . . answer every question. Call him anytime. M-600 SERIES--Compact, efficient, economical to operate. High pressure HM Series in 14 sizes, 55 to 651 bp . . . corru* gated furnace as shown. Low pressure LW Series in 16 sixes, 1.3J2 to 21,855 MBh . . . wet-back design provides additional primary heating surface. Both available as packaged units. SQUARE-HEAT TYPE "R"--Excellent source of heat for any medium size building, this one-piece, all-welded boiler fires efficiently from front or rear with any fuel. Twelve sizes range from 243 to 1,350 MBh 15 psi steam or 30 psi water up to 250 F. Available with attractive insulated jacket and packaged for oil, gas or combination oil-gas. WELDED SCOTTIE JR.--Ideal for small industry, 8 sizes of welded Kewanee Scottie Jr. Boilers range in certified ratings from 18 to 92 hp in the high pressure models ; . . 606 to 3,091 MBh in low pressure. Available as packaged unit with integrated burner for oil, gas or dual fuel firing. ROUND TYPE "R"--A rugged boiler with the capacity to serve today's larger, more extended homes. Its heavy steel plate construction assures many extra years of service. There are four Round "R" sizes from 108 to 243 MBh steam or water. Available with square or round insulated jacket. "500" SERIES--For heavy duty heating, power or process requirements of hospitals, schools, industries or apartment buildings, the steel riveted "500" Serie is available in 15 sizes, 32 to 321 hp, for 125.and.150 lb wp ... and for hightemperature hot water systems above 250 F. Two-pass tubular; firebox type. OW AND CW SERIES--Packaged with oil or gas burner and all controls ... for forced hot water beating of small to medium size homes. Compact design permits installation in any con venient location. Rated to produce 74 to 189 MBh. Also available as a boiler unit only, for oil or gas firing. TYPE "C" SERIES--Compact boiler . . . all-welded ... re quires a minimum of floor space. Produces ample steam for . heating large buildings at low cost. 15 psi steam or 30 psi water up to 250 F in 14 capacities 1,236 to 10,800 MBh. Corrugated crown sheet provides additional heating surface next to the fire. Has large firebox. Steel base. STORAGE WATER--Where large quantities of hot water are used at irregular intervals .. . and where exhaust or live steam is available--such as hotels, apartments, schools, hospitals, laundries, industrial buildings, etc. Capacities range from 92 to 2,240 gph. Equipped with supporting saddles. BRANCHES IN PRINCIPAL CITIES...STAFFED BT QUALIFIED HEATING SPECIALISTS Hooting System.? * Boilers Steel 339 The Babcock & Wilcox Co. 161 East 42nd Street, New York 17, N. Y. Offices in All Principal Cities Water-tube Boilers for Stationary Power Plants, and Marine Services . .. Superheaters .. . Economizers .... Air Heaters ... Puiverized-Coai Equipment.. . Chain Grate Stokers ... Oil, Gas, and Multifuel Burners ... Seamless and Welded Tubing and Pipe . .. Refractories . .. Process Equipment. B&W INTEGRAL-FURNACE BOILER, TYPE FM Shop'Assembled Steam Generator B&W Type FM Boiler combines the benefits of package steam with cost-saving big-boiler advantages. This compact self-contained unit has been widely ap plied to heating services in hospitals, schools, colleges, and other buildings. It has also gained wide acceptance throughout a broad range of industries--supplying steam for combination services. The Type FM Boiler is particularly suitable for small- and medium-sized plants where excessive fuel consumption and costly maintenance are often serious problems. And, even for some larger steam require ments, multiple-unit Type FM installations have proved more flexible in operation and more economical than one or more large boilers requiring costly field erection and close operating supervision. A large part of the total FM capacity now in service or on order consists of multiple-unit installations. ^ The Type FM Boiler is fast steaming and features automatic operation with special safety provisions. It quickly responds to load changes and operates at high efficiency over the load range. This versatile unit bums gas and/or oil, separately or in combination, with quick and easy changeover accomplished at the control panel. The Type FM Boiler is available in standard sizes for steam requirements to 40,000 lb per hr and for operating pressures to 235 psi. Many have been in stalled for higher pressures and with a moderate degree of superheat. Details are given in Bulletin G-7&-- copies sent on request.