Document 104vpKnanr7g6poOx6q6OBr0d
Inspection Date: Time: Media: Statute (s)/Program(s):
Type of inspection: Access:
Permittee Name: Facility or Site Name: Facility/Site Physical Address: (city, state, zip code) County/Parish:
Permit Number:
Region 5 Enforcement and Compliance Assurance Division
INSPECTION REPORT
7/28/22
Inspection Announced: No
Entry: 9:15 AM (CST)
Exit: 10:45 AM (CST)
Water
Clean Water Act, National Pollutant Discharge Elimination System (NPDES), Industrial
CEI - Compliance Evaluation Inspection
Granted
APS Grupa LLC APS Grupa LLC 10459 S. Muskegon
Chicago, Illinois 60617 Cook
Persons Participating in Inspection:
Title
Physical Scientist, EPA
Environmental Engineer, EPA
General Manager/VP Technology
Plant Manager
Name
Phone
Matthew (312) 886-2405 Schulte
Jason Hewitt (312) 353-3114
Rusty Napier (773) 437-9983
Tom Byrne (773) 437-9977
Email schulte.matthew@epa.gov
Hewitt.jason@epa.gov rnapier@apsgrupa.com
tbyrne@apsgrupa.com
Present at Present at Opening Closing Conference Conference
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Lead Inspector: Matthew Schulte
Region 5
schulte.matthew@epa.gov
(312) 886-2405
Page 1 of 23
APS Grupa LLC. Inspection Date(s):
Additional Persons Participating in Inspection:
Jason Hewitt
Region 5
Hewitt.jason@epa.gov
Supervisor Review: Molly Smith
MOLLY SMITH
Region 5
Digitally signed by MOLLY SMITH Date: 2022.09.29 08:45:01 -05'00'
smith.molly@epa.gov
7/28/2022 (312) 353-3114
(312) 353-8773
SECTION I - INTRODUCTION
Site Entry and Inspection Objectives
Region 5 Lead Inspector, Matthew Schulte, and inspector Jason Hewitt arrived at APS Grupa Inc. (the "Site" or "Facility"), located at 10459 S. Muskegon, Chicago, Illinois, at 09:15 AM (CST) on 7/28/2022 for an unannounced inspection. Inspectors presented their credentials to Rusty Napier and Tom Byrne and informed the Facility that this was an EPA Region 5 inspection to determine compliance with the Clean Water Act (CWA) and the National Pollutant Discharge Elimination System (NPDES) permit program. The inspection was conducted under the authority in Section 308 of the CWA. The table above identifies the attendees that participated in the inspection.
This report is based on information supplied by Facility representatives, observations made by the Region 5 inspectors, and records and reports maintained by the Facility Region 5. These include the following: direct observations made by the Region 5 inspectors, photographs taken by Region 5 inspectors, physical evidence collected by Region 5 inspectors, measurements taken by Region 5 inspectors, verbal or written statements made or supplied by Facility representatives during or subsequent to the on-site inspection, and materials, processes, data, photographs, or documents shown, demonstrated, or submitted to the Region 5 inspectors by Facility representatives during or subsequent to the on-site inspection. In addition, information gathered prior to or subsequent to the inspection from a review of U.S. EPA, State, and public records may be included in this report.
Facility/Site Description
Region 5 Lead Inspector confirmed the following facility information:
The Facility is a starch and phosphate distributer and a contract packaging facility. The Facility has been operating at the 10459 S. Muskegon location for approximately 2 years. The Facility is not currently covered under an NPDES Permit, but the EPA was informed during this inspection that an application for an Industrial User (IU) Permit has been submitted to the Metropolitan Water Reclamation of Greater Chicago (MWRD). Along with the permit application, the Facility is also currently working with consultants from Gabriel Environmental to develop a Stormwater Pollution Prevention Plan (SWPPP).
Page 2 of 23
APS Grupa LLC. Inspection Date(s):
SECTION II - OBSERVATIONS
Observations may not be in sequential order.
Unique Identifying No. MS5-OB-001
MS5-OB-002 MS5-OB-003 MS5-OB-004 MS5-OB-005 MS5-OB-006
Observation Current planned Facility sampling location includes waste from both sanitary and industrial wastewater sources. However, the IU permit application to MWRD states that the Facility does not currently have plans to adjust their categorical pretreatment limits with a Combined Wastestream Formula (CWF). Facility composite sampler set up inside to take 24-hour samples. Thermometer not present within sampler. Chemical storage within the Facility is located near a drain leading to the Facility settling tank. Empty chemical drums and containers are rinsed and stored outside near the rear truck loading area. Truck loading area in back South side of Facility contained some soy waste on the ground. All stormwater is directed to the sanitary sewer. No Stormwater reaches a public waterway.
7/28/2022
Area of Concern?
Yes
Yes Yes No Yes No
SECTION III - AREAS OF CONCERN
The presentation of areas of concern does not constitute a formal compliance determination or violation.
No. MS5-OB-001
MS5-OB-002
MS5-OB-003 MS5-OB-005
Current planned facility sampling location includes waste from both sanitary and industrial wastewater sources. However, the permit application to MWRD states that the Facility does not currently have plans to adjust their categorical pretreatment limits with a CWF. 40 CFR 403.6 outlines the method for calculating alternative pollutant limits at industrial facilities where regulated process effluent is mixed with other wastewaters prior to treatment. Facility composite sampler set up inside to take 24-hour samples. Thermometer not present within sampler. Sampling and holding requirements under 40 CFR Part 136 requires certain parameters to be preserved under a certain temperature. A thermometer is needed to confirm the temperature. Chemical storage within the Facility is located near a drain leading to the Facility settling tank. No secondary containment was present to prevent spills or other chemical releases from entering the Facilities treatment system. Truck loading area in back South side of Facility contained some soy waste on the ground. Food waste has potential to enter the stormwater system at the Facility, bypassing the treatment systems.
Page 3 of 23
APS Grupa LLC. Inspection Date(s):
7/28/2022
SECTION IV - CLOSING CONFERENCE AND FOLLOW UP
Closing Conference
The Lead Inspector held a closing conference with Facility personnel on 7/28/2022. During the closing conference, the Lead Inspector discussed the observations and Areas of Concern identified during the inspection. Observations and Areas of Concern have not yet been evaluated for a formal compliance determination.
Follow Up
The following items were requested by the inspector at the time of the inspection:
Industrial User permit application submitted to MWRD. Received by EPA on August 29, 2022. Monitoring Reports performed by the Facility. Received by EPA on August 5, 2022. Stormwater Pollution Prevention Plan. Not received as of date of this report.
SECTION V - LIST OF APPENDICES Appendix 1 - Photo Log [times listed on images are in Central Standard Time (CST)]
Page 4 of 23
Region 5 Enforcement and Compliance Assurance Division
Facility Name & Location:
APS Grupa LLC
10459 S. Muskegon Ave., Chicago, IL
60617
Date
Photograph Was
Taken:
7/28/2022
Photo Time:
No.: 1
9:41AM
Direction Photo Taken:
Photo Description: 24 Hour Sigma Composite Sampler.
Photographer: Jason Hewitt
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_001
Page 5 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 2
Time: 9:45AM
Direction Photo Taken: Down
Photo Description: Sampling location for facility with a combined wastestream.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_002
Page 6 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 3
Time: 9:48AM
Direction Photo Taken: South
Photo Description: Settling tank prior to discharge and sampling location.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_003
Page 7 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 4
Time: 9:57AM
Direction Photo Taken: North
Photo Description: Beginning of Facility soy process where water addition occurs.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_004 Page 8 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 5
Time: 9:59AM
Direction Photo Taken: South
Photo Description: Beginning of Facility soy process where water addition occurs.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_005 Page 9 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 6
Time:
Direction Photo Taken: 10:00AM
Photo Description: Facility water flow process prior to heat exchange.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_006
Page 10 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 7
Time: 10:00AM
Direction Photo Taken:
Photo Description: Internal monitoring flow meter.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_007
Page 11 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 8
Time: 10:01AM
Direction Photo Taken:
Photo Description: Tank V5, where pH adjustment is performed when necessary.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_008
Page 12 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 9
Time:
Direction Photo Taken: 10:01AM
Photo Description: pH meter reading connection to V5 for pH adjustment.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_009
Page 13 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 10
Time: 10:06AM
Direction Photo Taken: Down
Photo Description: Stormwater manhole in driveway on south side of facility.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_010
Page 14 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 11
Time: 10:08AM
Direction Photo Taken: South
Photo Description: Truck loading area south side of facility.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_011
Page 15 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 12
Time: 10:09AM
Direction Photo Taken: West
Photo Description: Empty chemical containers storage area.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_012
Page 16 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 13
Time: 10:10AM
Direction Photo Taken: West
Photo Description: Loading dock area and new tank awaiting installation in soy process.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_013
Page 17 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 14
Time: 10:13AM
Direction Photo Taken: East
Photo Description: Chemical storage area inside facility. Drain leads to Facility's wastewater treatment system and settling tank
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_014
Page 18 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 15
Time: 10:17AM
Direction Photo Taken: Northwest
Photo Description: Facility's back lot area.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_015
Page 19 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 16
Time: 10:18AM
Direction Photo Taken: West
Photo Description: Driveway from front parkling lot.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_016
Page 20 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 17
Time: 10:21AM
Direction Photo Taken: West
Photo Description: Fuel Tank located on the North side of facility.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_017
Page 21 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 18
Time: 10:24AM
Direction Photo Taken: Southeast
Photo Description: Water tower for fire suppression.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_018
Page 22 of 23
APS Grupa LLC. Inspection Date(s):
Facility Name & Location:
APS Grupa LLC 10459 S. Muskegon Ave., Chicago, IL 60617
Date Photograph Was Taken: 7/28/2022
Photo No.: 19
Time: 10:35
Direction Photo Taken: East
Photo Description: North side loading and unloading dock for trucks and rail cars.
Photographer: Jason Hewitt
7/28/2022
Camera: Olympus TG-6 (S/N BJ5B20242)
File: APS_Grupa_019
Page 23 of 23